Setting and Monitoring Safety Output Terminals: Outputs (NE1A-SCPU02)
Explicit
Service
message
Monitor Mode for
Read
Terminal Mainte-
nance Information
Write
SV for Output Total
Read
ON Time or
Contact Operation
Counter
Write
Read Output Total
Read
ON Time or
Contact Operation
Counter
Reset Output Total
Reset
ON Time or
Contact Operation
Counter
Read Monitor Sta-
Read
tus of Output Total
ON Time or Contact
Operation Counter
Read Safety Output
Read
Normal Flag
Read Safety Output
Read
Error Information
Cause
Read AND of Safety
Read
Output Normal
Flags
Read OR of Moni-
Read
tor Status of Output
Total ON Times or
Contact Operation
Counters
Function
Service
Reads the monitor mode of
0E hex
maintenance information for
the output (1 to 8) specified by
the Instance ID.
Writes the monitor mode of
10 hex
maintenance information for
the output (1 to 8) specified by
the Instance ID.
Reads the SV of the total ON
0E hex
time (unit: seconds) or contact
operation counter (unit: opera-
tions) for the output (1 to 8)
specified by the Instance ID.
Reads the SV of the total ON
10 hex
time (unit: seconds) or contact
operation counter (unit: opera-
tions) for the output (1 to 8)
specified by the Instance ID.
Reads the total ON time (unit:
0E hex
seconds) or contact operation
counter (unit: operations) for
the output (1 to 8) specified by
the Instance ID.
Resets to 0 the total ON time
05 hex
(unit: seconds) or contact oper-
ation counter (unit: operations)
for the output (1 to 8) specified
by the Instance ID.
Reads the monitor status of the
0E hex
total ON time or contact opera-
tion of the number (1 to 8)
specified by the Instance ID.
Reads the normal flag status of
0E hex
the number (1 to 8) specified by
the Instance ID.
Reads the cause for the normal
0E hex
flag status of the number (1 to
8) specified by the Instance ID
being OFF (error).
Reads the logical AND of the
0E hex
normal flag status for all out-
puts 1 to 8.
Reads the logical OR of the
0E hex
monitor status of the total ON
time or contact operation
counter for all outputs 1 to 8.
Command
Class
In-
At-
code
stance
tribute
ID
ID
ID
3B
01 to 08
65 hex
hex
hex
3B
01 to 08
65 hex
hex
hex
3B
01 to 08
68 hex
hex
hex
3B
01 to 08
68 hex
hex
hex
3B
01 to 08
66 hex
hex
hex
3B
01 to 08
66 hex
hex
hex
3B
01 to 08
67 hex
hex
hex
3B
01 to 08
05 hex
hex
hex
3B
01 to 08
6E hex
hex
hex
3C
01 hex
05 hex
hex
3C
01 hex
72 hex
hex
Appendix A
Response
Data size
---
1 byte
00 hex: Total ON time
mode
01 hex: Contact opera-
tion counter
mode
1 byte
---
00 hex: Total
ON time mode
01 hex: Contact
operation
counter mode
---
4 bytes
0000 0000 to FFFF
FFFF hex
(0 to 4,294,967,295)
4 bytes
---
0000 0000 to
FFFF FFFF hex
(0 to
4,294,967,295)
---
4 bytes
0000 0000 to FFFF
FFFF hex
(0 to 4,294,967,295)
---
---
---
1 byte
00 hex: In range
01 hex: Out of range
(over monitor value)
---
1 byte
00 hex: Error
01 hex: Normal
---
1 byte
00 hex: No error
01 hex: Invalid configu-
ration
02 hex: Overcurrent
detection
03 hex: Short-circuit
detection
04 hex: High constant
error
05 hex: Error in other
channel of dual
channels
06 hex: Internal relay
circuit error
07 hex: Relay error
08 hex: Data error
between dual
channel outputs
09 hex: Detection of
short circuit
between wires
---
1 byte
00 hex: Error
01 hex: All normal
---
1 byte
00 hex: All in range
01 hex: Output out of
range (over
monitor value)
249