Omron NE1A Series Manual page 244

Safety network controllers
Hide thumbs Also See for NE1A Series:
Table of Contents

Advertisement

Setting and Monitoring Safety Output Terminals: Outputs (NE1A-SCPU01-V1)
Explicit
Service
message
Monitor Mode for
Read
Terminal Mainte-
nance Information
Write
SV for Output Total
Read
ON Time or Contact
Operation Counter
Write
Read Output Total
Read
ON Time or Contact
Operation Counter
Reset Output Total
Reset
ON Time or Contact
Operation Counter
Read Monitor
Read
Status of Output
Total ON Time or
Contact Operation
Counter
Read Safety Out-
Read
put Normal Flag
Read Safety
Read
Output Error
Information Cause
Read AND of
Read
Safety Output a
Normal Flags
Read OR of Monitor
Read
Status of Output
Total ON Times or
Contact Operation
Counters
Function
Service
Reads the monitor mode of
0E hex
maintenance information for
the output (1 to 8) specified by
the Instance ID.
Writes the monitor mode of
10 hex
maintenance information for
the output (1 to 8) specified by
the Instance ID.
Reads the SV of the total ON
0E hex
time (unit: seconds) or contact
operation counter (unit: opera-
tions) for the input (1 to 8)
specified by the Instance ID.
Writes the SV of the total ON
10 hex
time (unit: seconds) or contact
operation counter (unit: opera-
tions) for the input (1 to 8)
specified by the Instance ID.
Reads the total ON time (unit:
0E hex
seconds) or contact operation
counter (unit: operations) for
the input (1 to 8) specified by
the Instance ID.
Resets to 0 the total ON time
05 hex
(unit: seconds) or contact
operation counter (unit: opera-
tions) for the output (1 to 8)
specified by the Instance ID.
Reads the monitor status of
0E hex
the total ON time or contact
operation for the output (1 to 8)
specified by the Instance ID.
Reads the normal flag status
0E hex
of the number (1 to 8) specified
by the Instance ID.
Reads the cause for the
0E hex
normal flag of the number (1 to
8) specified by the Instance ID
being OFF (error).
Reads the logical AND of all
0E hex
outputs 1 to 8.
Reads the logical OR of the
0E hex
monitor status of the total ON
time or contact operation
counter for all outputs 1 to 8.
Command
Class
In-
At-
code
stance
tribute
ID
ID
ID
3B
01 to 08
65 hex
hex
hex
3B
01 to 08
65 hex
hex
hex
3B
01 to 08
68 hex
hex
hex
3B
01 to 08
68 hex
hex
hex
3B
01 to 08
66 hex
hex
hex
3B
01 to 08
66 hex
hex
hex
3B
01 to 08
67 hex
hex
hex
3B
01 to 08
05 hex
hex
hex
3B
01 to 08
6E hex
hex
hex
3C
01 hex
05 hex
hex
3C
01 hex
72 hex
hex
Appendix A
Response
Data size
---
1 byte
00 hex: Total ON time
mode
01 hex: Contact operation
counter mode
1 byte
---
00 hex: Total
ON time mode
01 hex: Contact
operation
counter mode
---
4 bytes
0000 0000 to FFFF FFFF
hex (0 to 4,294,967,295)
4 bytes
---
0000 0000 to
FFFF FFFF hex
(0 to
4,294,967,295)
---
4 bytes
0000 0000 to FFFF FFFF
hex (0 to 4,294,967,295)
---
---
---
1 byte
00 hex: In range
01 hex: Out of range (over
monitor value)
---
1 byte
00 hex: Error
01 hex: Normal
---
1 byte
00 hex: No error
01 hex: Invalid configura-
tion
02 hex: Overcurrent
detection
03 hex: Short-circuit
detection
04 hex: High constant error
05 hex: Error in other chan-
nel of dual chan-
nels
06 hex: Internal relay cir-
cuit error
07 hex: Relay error
08 hex: Data error between
dual channel
outputs
09 hex: Detection of short
circuit between
wires
---
1 byte
00 hex: Error
01 hex: All normal
---
1 byte
00 hex: All in range
01 hex: Output out of range
(over monitor
value)
245