Omron NE1A Series Manual page 115

Safety network controllers
Hide thumbs Also See for NE1A Series:
Table of Contents

Advertisement

Function Block Editing
Fault Present Setting
116
Fault Present is a diagnostic status bit supported in some function blocks by
selecting the checkbox located on the In/Out Setting or Out Point Tab Page of
the function block properties. If the Fault Present checkbox is selected, an
additional Fault Present output will be displayed on the function block.
Example: Safety Gate Monitoring Function Block (SGATE)
Out Point Tab Page in the Safety Gate
Monitoring Function Block Editing Dialog Box
Section 6-3
Safety Gate
Safety Gate
Monitoring
Monitoring Function
Function Block
Block with
with Default
Maximum Inputs
Settings
and Outputs Enabled