Mounting And Installation Instructions - Dantherm CDP 35 Service Manual

Hide thumbs Also See for CDP 35:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 17

Mounting and installation instructions

Introduction
This section contains all necessary information for correct mounting of the duct kit and
the dehumidifier.
The electrical installation is described at the end of this section.
Mounting of
Please follow this procedure to mount the CDP 35/45/65:
CDP 35/45/65
Important
 Do not place the dehumidifier close to a heating source, e.g. a radiator
 Doors and windows must be kept closed when the dehumidifier is in function
 To make sure that the room air passes freely through the dehumidifier, air inlet and
Access to the con-
Please follow this procedure to get access to the control:
trol
23
Step
1
Fix the wall suspension bar supplies
with the unit to the wall. It is im-
portant to fix it horizontally in order
to ensure correct condensate outlet.
Recommended distance from dehu-
midifier to:
Ceiling:
225 mm
Floor:
225 mm
2
Hang up the dehumidifier
air outlet openings must be free
Step
1
Dismount the front Remove the screws (2 pcs.) at the top of the dehumidifier.
Lift up the casing and pull it horizontally away from the dehumidifier.
2
Remove the screws on the front of the lid that is placed on top of the com-
pressor (the control is placed in that box)
3
Push the lid against the back of the dehumidifier and pull it away from the
box. There is now access to the control.
Action
Action
Continued overleaf

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cdp 45Cdp 65Cdp 40 t

Table of Contents