Download Print this page

Mounting And Installation Instructions - Dantherm CDP 35 Service Manual

Hide thumbs Also See for CDP 35:

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 17

Mounting and installation instructions

Introduction
This section contains all necessary information for correct mounting of the duct kit and
the dehumidifier.
The electrical installation is described at the end of this section.
Mounting of
Please follow this procedure to mount the CDP 35/45/65:
CDP 35/45/65
Step
Important
• Do not place the dehumidifier close to a heating source, e.g. a radiator
• Doors and windows must be kept closed when the dehumidifier is in function
• To make sure that the room air passes freely through the dehumidifier, air inlet and
Access to the
Please follow this procedure to get access to the control:
control
Step
1
Fix the wall suspension bar supplies
with the unit to the wall. It is
important to fix it horizontally in order
to ensure correct condensate outlet.
Recommended distance from
dehumidifier to:
Ceiling:
225 mm
Floor:
225 mm
2
Hang up the dehumidifier
air outlet openings must be free
1
Dismount the front Remove the screws (2 pcs.) at the top of the
dehumidifier. Lift up the casing and pull it horizontally away from the
dehumidifier.
2
Remove the screws on the front of the lid that is placed on top of the
compressor (the control is placed in that box)
3
Push the lid against the back of the dehumidifier and pull it away from the
box. There is now access to the control.
Action
Action
Continued overleaf
23