Table 6-4 Environmental specifications
Item
Temperature
Maximum temperature
change rate
Relative humidity (RH, non-
condensing)
Altitude
Vibration
Shock
Issue 02 (2019-03-13)
Specifications
l Operating temperature: 5°C to 40°C (41°F to 104°F)
l Storage temperature: –40°C to +65°C (–40°F to
+149°F)
l Long-term storage temperature: 21°C to 27°C (69.8°F to
80.6°F)
NOTE
l The maximum temperature of the supercapacitor is 33°C (CPU
power = 165 W), 35°C (150W ≤ CPU power < 165 W), and
40°C (CPU power < 150 W).
l The maximum operating temperature of the server is 35°C
(95°F) if 6144, 6146, 8176, 8170, or 6150 CPUs are used.
l If one fan fails, the maximum operating temperature of the
server is 5°C (9°F) lower than that in normal cases.
l The XH628 V5 supports mixed configuration with only the
XH628 V3 nodes in one chassis. In this case, the supported
operating environment temperature is the same as that of the
XH628 V5.
20°C/h (36°F/h)
l Operating: 10% to 85%
l Storage: 5% to 95%
l Long-term storage humidity: 30% RH to 69% RH (non-
condensing)
l Operating altitude: ≤ 3000 m (9842.4 ft)
l Storage altitude: ≤ 12,000 m (39369.6 ft)
NOTE
When the altitude is higher than 900 m (2952.72 ft), the operating
temperature decreases by 1°C (1.8°F) for every altitude increase of
300 m (984.24 ft).
l At an altitude of over 3000 m (9842.4 ft), only Titanium
PSUs can be used.
l HDDs are not supported at an altitude of over 3000 m
(9842.4 ft).
One cyclical sweep in each axial direction at the rate of 0.1
oct/min, with a total of three axial directions
5 Hz to 10 Hz: 5 mm (0.20 in., peak-to-peak value)
10 Hz to 100 Hz: 1 m/s
Half sine wave, peak acceleration of 2 G, 11 ms, 3 times for
each surface, and a total of three axial directions