Mounting Instructions - Projecta INTELLI-CHARGE IC7 Manual

12 volt, 7 stage switchmode
Table of Contents

Advertisement

MOUNTING INSTRUCTIONS

INTELLI-CHARGE Chargers are designed for indoor, out of weather use only. Ensure that
both charger and battery are in a well-ventilated space during charging.
The battery charger end plates include a mounting flange for easy mounting. If
permanently fixed the charger should be mounted to a suitable horizontal or vertical
panel, with at least 10cm clearance from the end plates to provide adequate ventilation
for the cooling fan.
PERMANENT WIRING TO BATTERY
It is possible to hard wire the DC charging leads to the battery for permanent installations.
You will need 2 x ring terminals, an inline fuse holder and a fuse with a rating equal
to or greater than twice the chargers output. (See below)
IC7 = use supplied wiring harness (15 Amp fuse)
IC7W = 15 Amp fuse
IC10 = 20 Amp fuse
IC15 = 30 Amp fuse
3.5mm
mounting hole
13