Kindermann MultiSwitch 21 HDBT Mounting Instructions page 44

Table of Contents

Advertisement

Available languages

Available languages

Command
EDID/[xx]/[yy].
EDIDM[xx]B[yy].
Baudrate[XXX].
44
Description
Asign EDID to the inputs:
Input [xx] uses EDID [yy].
[xx] = input, the value must
be 00 - 02, 00 means all
inputs, 01 or 02 means
input 1 or 2.
[yy] = EDID preset, the value
is 01 - 12.
Please note: DIP switch
must be set to 1111!
The input captures the EDID
from the output.
[xx] = output 01 or 02
[yy] = input 00 - 02), while
00 means all input ports, 01
or 02 means the individual
inputs. ;
Set control baud rate of
the MultiSwitch 21 HDBT
to [XXX]
[XXX] 115200, 57600,
38400, 19200, 9600
Command & Feedback Example
Input 02 EDID Upgrade OK By 01
Internal EDID!
5
Input 01 EDID Upgrade OK By 02 EXT
EDID!
Set Local RS232 Baudrate is 9600!