Kindermann MultiSwitch 21 HDBT Mounting Instructions page 19

Table of Contents

Advertisement

Available languages

Available languages

9. RS232 and TCP/IP control protocoll
Befehl
Beschreibung
RS232ONSAVE:
The MultiSwitch 21 HDBT can
Baud rate: 9600
[Y],[xxx].
send a power on command
to the display device as soon
To control the device via TCP/IP, use port:
as it detects a video signal
on any of the inputs. Use the
command to save the power
on command.
Y = baud rate 1 = 2400; 2 =
4800; 3 = 9600; 4 = 19200;
5 = 38400; 6 = 57600; 7 =
115200; xxx must be the
power on command of the
display device.
RS232OFFSAVE:
The MultiSwitch 21 HDBT can
[Y],[xxx].
send a power off command to
the display device as soon as
it can't detect a video signal
on any of the inputs anymore.
Use this command to save
the power off command.
Y = baud rate 1 = 2400; 2 =
4800; 3 = 9600; 4 = 19200;
5 = 38400; 6 = 57600; 7 =
115200; xxx must be the
power off command of the
display device.
RS232DLYOUT
Set the delay for sending the
[xx]:[yy].
display off command, when
no input is detected. Default
setting is 10 minutes = 600
seconds.
[xx] 00 - 02, 00 means all
inputs.
[yy] = delay in seconds
DE
Data bit: 8
Beispiel für die Rückmeldung
Save PON
Stop bit: 1
Parity bit: none
Command:YYYYY,Baudrate Is 9600!
4001
Save POFF
Command:TTTTTT.,
Baudrate Is 9600!
Set POFF Delay To 10 Second(s)!
19