Atex/iecex/sil2.
flameproof xenon sil 2
beacons for use in flammable gas and dust (18 pages)
Summary of Contents for E2S STExB2X05DC012
Page 1
For use in Flammable Gas and Dust Atmospheres STExB2X05 STExB2X10 STExB2X15 STExB2X21 1) Product Table Nom. Nom. Standard Model Voltage Range Operating Max Current Voltage Current* STExB2X05DC012 12Vdc 12-14Vdc 585mA 600mA STExB2X05DC024 (-SIL) 24Vdc 20-28Vdc 295mA 350mA STExB2X05DC048 48Vdc 42-54Vdc 145mA 150mA...
Page 2
Electrical Apparatus for Explosive Gas Atmospheres - Part 1: X21DC048 Ex tb IIIC T131°C Db Ta -50°C to +70°C Flameproof Enclosures 'd' European Safety Systems Ltd. Impress House, Mansell Road, Acton, London W3 7QH www.e2s.com Tel: +44 (0)208 743 8880 Document No. D199-00-201-IS Issue 4 07-10-21...
Page 3
Zone 2 normal operation, and if it does, it will only exist for a short time. European Safety Systems Ltd. Impress House, Mansell Road, Acton, London W3 7QH www.e2s.com Tel: +44 (0)208 743 8880 Document No. D199-00-201-IS Issue 4 07-10-21...
Warning – Hot surfaces. External surfaces and internal components may be hot after operation, take care when handling the equipment. European Safety Systems Ltd. Impress House, Mansell Road, Acton, London W3 7QH www.e2s.com Tel: +44 (0)208 743 8880 Document No. D199-00-201-IS Issue 4 07-10-21...
Page 5
This is particularly important when using cables with large cross-sectional areas such as 2.5mm². European Safety Systems Ltd. Impress House, Mansell Road, Acton, London W3 7QH www.e2s.com Tel: +44 (0)208 743 8880 Document No. D199-00-201-IS Issue 4...
Page 6
DIP switch on the PCBA (See Fig 6). Figure 7: Removal of Lens. Figure 6: DIP Switch Location. European Safety Systems Ltd. Impress House, Mansell Road, Acton, London W3 7QH www.e2s.com Tel: +44 (0)208 743 8880 Document No. D199-00-201-IS Issue 4...
Potential electrostatic charging hazard - Clean only with a damp cloth. European Safety Systems Ltd. Impress House, Mansell Road, Acton, London W3 7QH www.e2s.com Tel: +44 (0)208 743 8880 Document No. D199-00-201-IS Issue 4 07-10-21...
Page 8
WRITTEN CONSENT. IMPRESS HOUSE 03/07/19 R.N.POTTS STANDARDS MANSELL ROAD EUROPEAN SAFETY SYSTEMS LTD. ACTON DRAWING NUMBER ALTERNATIVE MATERIAL AS PER LATEST DATE OF ISSUE SHOWN ABOVE LONDON W3 7QH SCALE SHEET APPROVED DATE STExB2 BEACONS WWW.E2S.COM D199-06-201 NTS 1 03/07/19 R.N.POTTS...
Page 9
WRITTEN CONSENT. IMPRESS HOUSE 03/07/19 R.N.POTTS STANDARDS MANSELL ROAD EUROPEAN SAFETY SYSTEMS LTD. ACTON DRAWING NUMBER AS PER LATEST DATE OF ISSUE SHOWN ABOVE LONDON W3 7QH SCALE SHEET ALTERNATIVE MATERIAL APPROVED DATE STExB2 BEACONS WWW.E2S.COM D199-06-201 NTS 2 03/07/19 R.N.POTTS...
Notified Body No.: 0539 Borupvang 5A, 2750 Ballerup, Denmark EU‐type Examination Certificate (Module B): DEMKO 16ATEX1466X Notified Body for Quality Assurance Notification / Conformity to EU‐type Sira Certification Service based on Notified Body No.: 2813 quality assurance of the production process (Module D): CSA Group Netherlands B.V, Utrechtseweg 310, 6812 AR, Arnhem, Netherlands Quality Assurance Notification (Module D): SIRA 05 ATEX M342 Provisions fulfilled by the equipment: II 2G Ex db IIC T6…T3 Gb II 2D Ex tb IIIC T82°C…T137°C Db IP6X Dust Protection to EN60079‐0 / EN60079‐31 Standards applied: EN IEC 60079‐0: 2018 EN 60079‐1: 2014 EN 60079‐31: 2014 Directive 2014/30/EU: Electromagnetic Compatibility Directive (EMC) Standards applied: EN 61000‐6‐1:2007 EN 61000‐6‐2:2005 EN 61000‐6‐3:2007 / A1:2011 / AC: 2012 EN 61000‐6‐4:2007 / A1: 2011 Directive 2011/65/EU: Restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS) The product and all the components contained within it are in accordance with the restriction of the use of hazardous substances in electrical and electronic equipment, including amendment by Directive 2015/863/EU. Regulation (EC) 1907/2006: Registration, Evaluation, Authorisation and Restriction of Chemicals (REACH) The product and all the components contained within it are free from substances of very high concern. Other Standards and Regulations EN 60529:1991 / A1:2000 / A2:2013 ‐ Degrees of protection provided by enclosures (IP code) – enclosure rated IP66 E2S Telephone: +44 (0)20 8743 8880 Fax: +44 (0)20 8740 4200 Email: sales@e2s.com www.e2s.com DC‐070_Issue_G (STEx).docx ‐ Page 1 of 2 ‐ QAF_252_Issue_5...
Page 11
EU Declaration of Conformity On behalf of European Safety Systems Ltd., I declare that, on the date the equipment accompanied by this declaration is placed on the market, the equipment conforms with all technical and regulatory requirements of the above listed directives, regulations and standards. This Declaration is issued under the sole responsibility of the manufacturer. Martin Streetz Document No.: DC‐070_Issue_G Quality Assurance Manager Date and Place of Issue: London, 03/12/2021 E2S Telephone: +44 (0)20 8743 8880 Fax: +44 (0)20 8740 4200 Email: sales@e2s.com www.e2s.com DC‐070_Issue_G (STEx).docx ‐ Page 2 of 2 ‐ QAF_252_Issue_5...
Need help?
Do you have a question about the STExB2X05DC012 and is the answer not in the manual?
Questions and answers