T O R Q U E S E T T I N G S F O R S C R E W S
The hex-head screws holding either the panels or the base MUST be tightened with a
torque wrench (not included).
TORQUE SETTINGS:
lbf-in = Pound Force Inches
kgf-cm = Kilogram Force Centimeters
CAUTION! DO NOT OVER TORQUE SCREWS AS THIS CAN CAUSE LEAKAGE ISSUES!
TO CONFIRM THE IP65 INTEGRITY AFTER A LAMP REPLACEMENT, TEST FIXTURE
USING THE ELATION IP TESTER. CONTACT ELATION SERVICE FOR MORE DETAILS.
CAUTION! THE USE OF PROTECTIVE
GLOVES AND SAFETY GOGGLES IS
STRONGLY RECOMMENDED WHILE
PERFORMING THE IP PRESSURE
TEST! AVOID PLACING YOUR FACE,
EYES,
HANDS,
PROXIMITY TO THE FIXTURE'S LENS
WHILE PERFORMING THE TEST!
Test Type
Pressure Test
ETC
IN
CLOSE
IP PRESSURE TESTING PARAMETERS
Low Pressure Limit
2.90 psi (20.00 KPa)
High Pressure Limit
3.36 psi (23.00 KPa)
11
Hold Time
15s