C O N T E N T S General Information Limited Warranty (USA Only) IP65 Rated Safety Guidelines Maintenance Guidelines Overview Installation Guidelines Accessory Installation Remote Device Management (RDM) Fan Modes Control Panel Zone Linking FX Functions and Features System Menu DMX Set Up DMX Traits Zone Layouts...
Fixture Interconnect Splice (x2) IP65 Locking Power Cable (x1) Safety Cable (x1) CUSTOMER SUPPORT Contact ELATION Service for any product related service and support needs. Also visit forums.elationlighting.com with questions, comments, or suggestions. ELATION SERVICE USA - Monday - Friday 8:00am to 4:30pm PST 323-582-3322 | support@elationlighting.com...
It is the owner’s responsibility to establish the date and place of purchase by acceptable evidence, at the time service is sought. B. For warranty service, send the product only to the Elation Professional factory. All shipping charges must be pre-paid. If the requested repairs or service (including parts replacement) are within the terms of this warranty, Elation Professional will pay return shipping charges only to a designated point within the United States.
I P 6 5 R AT E D The International Protection (IP) rating system is commonly expressed as “IP” (Ingress Protection) followed by two numbers (i.e. IP65), where the numbers define the degree of protection. The first digit (Foreign Bodies Protection) indicates the extent of protection against particles entering the fixture, and the second digit (Water Protection) indicates the extent of protection against water entering the fixture.
S A F E T Y G U I D E L I N E S This fixture is a sophisticated piece of electronic equipment. To guarantee smooth operation, it is important to follow all instructions and guidelines in this manual. Elation Professional is not responsible for injury and/or damages resulting from the misuse of this fixture due to the disregard of the information printed in this manual.
Page 8
S A F E T Y G U I D E L I N E S For Your Own Personal Safety, Please Read and Understand This Manual Completely Before You Attempt To Install Or Operate This Unit! • Do not touch the fixture housing during operation, as it may be hot. •...
Regular inspections are recommended to insure proper function and extended life. There are no user serviceable parts inside this fixture. Please refer all other service issues to an authorized Elation service technician. Should you need any spare parts, please order genuine parts from an authorized Elation dealer.
O V E R V I E W Fixture Interconnect L-Track Fixture Slot Display Interconnect Screen Slot Mode Button Omega Bracket Mounts Down Enter Button Button Button Mounting Yoke Fixture Valve Interconnect Slot Safety Cable Loop Omega Bracket Mounts Yoke Fixture Adjustment Interconnect...
I N S TA L L AT I O N G U I D E L I N E S FLAMMABLE MATERIAL WARNING Keep fixture minimum 5.0 feet (1.5m) away from flammable materials and/or pyrotechnics. ELECTRICAL CONNECTIONS A qualified electrician should be used for all electrical connections and/or installations.
Page 12
I N S TA L L AT I O N G U I D E L I N E S OMEGA BRACKET WITH CLAMP INSTALLATION When mounting the fixture to a truss, secure an appropriately rated professional grade rigging clamp to the included Omega Brackets using an M10 or M12 screw fitted through the center hole of the Omega Brackets, as described below.
Page 13
I N S TA L L AT I O N G U I D E L I N E S FIXTURE INSTALLATION This fixture is fully operational in three different mounting positions: hanging upside-down, mounted sideways on trussing, or set on a flat level surface. Be sure this fixture is kept well away from any flammable materials (decoration etc.).
Page 14
I N S TA L L AT I O N G U I D E L I N E S FIXTURE INTERCONNECT SPLICE Individual fixtures can be physically linked together using the Fixture Interconnect Slots located along the top, bottom, and sides of the fixture, in conjunction with included Fixture Interconnect Splices.
Page 15
I N S TA L L AT I O N G U I D E L I N E S ARRAY LIMITATIONS Due to limitations on the amount of weight that the Fixture Interconnect Splices can support, the maximum number of fixtures that can be suspended from a single point of support is as follows: •...
Page 16
I N S TA L L AT I O N G U I D E L I N E S ART-NET | sACN CONNECTION When connecting fixture to a network switch to control multiple devices, a Gigabit Ethernet Switch that supports IGMP (Internet Group Management Protocol) is required. Using a Gigabit Ethernet Switch that does not support IGMP can cause erratic behavior of all connected devices to the switch.
Page 17
LEDs. This issue is not specific only to ELATION lighting fixtures, it is a common issue with lighting fixtures from all manufacturers. Although there is no true way to fully prevent this issue from happening, the guidelines below can prevent any potential damage from occurring if followed.
A C C E S S O RY I N S TA L L AT I O N FROST FILTERS This fixture can be fitted with optional filters: a black glass or ND filter, a medium frost filter, a 1x60° frost filter, or a 60x1° frost filter. The installation procedure for all filters is identical. Simply align the eight (8) screw holes on the frame of the frost filter with the eight (8) matching holes on the fixture’s lens frame.
R E M O T E D E V I C E M A N A G E M E N T ( R D M ) NOTE: In order for RDM to work properly, RDM enabled equipment must be used through- out the entire system, including DMX data splitters and wireless systems.
F A N M O D E S The Pulse Panel is a high-performance fixture suited for multiple applications. For noise critical environments such as Theater, Opera, or Orchestral Halls, it offers various fan operation modes which remove unwanted noise distractions for the audience and performers. Fan Modes can be changed remotely via the DMX control channel, allowing the fixture to offer high output or whisper-silent operation at a moment’s notice.
Screen Lock setting should be configured so that the screen and control will lock after the selected period of inactivity. SOFTWARE UPDATE: AN ELATION C-LOADER II CAN BE USED TO UPDATE THE FIXTURE TO THE LATEST SOFTWARE. To order this device, please contact Elation Support for further details.
Z O N E L I N K I N G The Pulse Panel stands out from other fixtures due to its ability to offer more individually controllable zones and LED types. However, different levels of control may sometimes be required, so multiple selectable DMX modes with varying numbers of control zones are offered to cater to these needs.
F X F U N C T I O N S A N D F E AT U R E S Multi-zone fixtures, such as the Pulse Panel, can often command a significant investment of time and effort to create and record impactful effects, and in some cases, the limited number of DMX channels prevents the fixture from being used at its full potential capacity.
S YS T E M M E N U DMX Address 001 - 512 Set DMX address 3CH Xenon Strb 12CH Simple Strb 22CH Strobe FX 45CH Large Pixel Select DMX channel DMX Mode 60CH Simple Pxl mode 170CH Pxl Focus 88CH Basic Full 178CH Full Mode 156Ch Raw Mode...
Page 25
S YS T E M M E N U RGB Dimmer 000% - 100% 0 - 255 Green 0 - 255 Manually configure each Manual Control unit parameter Blue 0 - 255 CW Strobe Dimmer 000% - 100% Virtual Color Enable or disable CONTROL Primary...
Page 26
S YS T E M M E N U Default Control Yes / No Outer Link Centr Outer CW Linking Outer CW Off Configure how you would RGB Line Top CW Zone Linking like the Pixel Zones to RGB Line Top be operationally linked RGB Line Linking RGB Line Bot RGB...
Page 27
S YS T E M M E N U Display current DMX DMX Values Green value of each parameter INFORMATION Product IDs RDM UID Display RDM UID (continued) Error Logs Fixture Errors Display logged errors Display current Software Version Vx.x software version Update Firmware On / Off Update software...
D M X S E T U P DMX-512: DMX is short for Digital Multiplex. This is a universal protocol used as a form of communication between intelligent fixtures and controllers. A DMX controller sends DMX data instructions from the controller to the fixture. DMX data is sent as serial data that travels from fixture to fixture via the DATA “IN”...
Page 29
D M X S E T U P Special Note: Line Termination. When longer runs of cable are used, you may need to use a terminator on the last unit to avoid erratic behavior. A terminator is a 110-120 ohm 1/4 watt resistor which is connected between pins 2 and 3 of a male XLR connector (DATA + and DATA -).
D M X T R A I T S Fixt. Function Snap Part Values Value Master Dimmer 0 - 255 Intensity 0 → 100% Strobe Dimmer Master 0 - 255 Intensity 0 → 100% CW Strobe Duration 0 - 255 Min →...
Page 31
D M X T R A I T S Fixt. Function Snap Part Values Value CW Strobe Effect Selection Idle 1 - 40 FX Selection 1 → 40 41 - 127 Idle 128 - 167 FX Selection 1 → 40 168 - 255 Idle CW Strobe Effect Speed 0 - 126...
Page 32
D M X T R A I T S Fixt. Function Snap Part Values Value RGB Effect Selection Idle 1 - 30 FX Selection 1 → 30 31 - 100 Idle 101 - 131 FX Selection 1 → 30 132 - 200 Idle 201 - 211 RGB Effects 1 →...
Page 33
D M X T R A I T S Fixt. Function Snap Part Values Value Dim Modes 0 - 20 Standard 21 - 40 Stage 41 - 60 61 - 80 Architectural 81 - 100 Theatre 101 - 120 Stage 2 Dimmer Delay Time 0.1s 0.2s...
Page 34
D M X T R A I T S Fixt. Function Snap Part Values Value Control 0 - 29 Idle 30 - 39 Fan Mode: Auto 40 - 49 Fan Mode: Silent 50 - 59 Fan Mode: High 60 - 99 Idle Refresh Rate (Hz) 1000...
Page 35
D M X T R A I T S Fixt. Function Snap Part Values Value Refresh Rate (Hz) (continued) 1260 1270 1280 1290 1300 1310 1320 1330 1340 1350 1360 1370 1380 1390 1400 1410 1420 1430 1440 1450 Main 22 14 12 1460 1470...
Page 36
D M X T R A I T S Fixt. Function Snap Part Values Value Zone Linking 180 - 181 Zones to Default Top and Bottom CW Strobe Link 182 - 183 to Center Top and Bottom CW Strobe Inac- 184 - 185 tive RGB StrobeLine Link to Top Cen-...
Page 37
D M X T R A I T S Fixt. Function Snap Part Values Value Red 5 27 25 0 - 255 Red Saturation 0 → 100 Green 5 28 26 0 - 255 Green Saturation 0 → 100 Blue 5 29 27 0 - 255 Blue Saturation 0 →...
Page 38
D M X T R A I T S Fixt. Function Snap Part Values Value Red 12 0 - 255 Red Saturation 0 → 100 Green 12 0 - 255 Green Saturation 0 → 100 Blue 12 0 - 255 Blue Saturation 0 →...
Page 39
D M X T R A I T S Fixt. Function Snap Part Values Value Red 19 0 - 255 Red Saturation 0 → 100 Green 19 0 - 255 Green Saturation 0 → 100 Blue 19 0 - 255 Blue Saturation 0 →...
Page 40
D M X T R A I T S Fixt. Function Snap Part Values Value CW Strobe 4 36 52 0 - 255 Intensity 0 → 100 CW Strobe 5 0 - 255 Intensity 0 → 100 CW Strobe 6 0 - 255 Intensity 0 →...
Page 41
D M X T R A I T S Fixt. Function Snap Part Values Value CW Strobe 25 0 - 255 Intensity 0 → 100 CW Strobe 26 0 - 255 Intensity 0 → 100 CW Strobe 27 0 - 255 Intensity 0 →...
Page 42
D M X T R A I T S Fixt. Function Snap Part Values Value CW Strobe 46 140 118 0 - 255 Intensity 0 → 100 CW Strobe 47 141 119 Strb 0 - 255 Intensity 0 → 100 CW Strobe 48 142 120 0 - 255...
Page 43
D M X T R A I T S Fixt. Function Snap Part Values Value StrobeLine Red 7 161 139 0 - 255 Red Saturation 0 → 100 StrobeLine Green 7 162 140 0 - 255 Green Saturation 0 → 100 StrobeLine Blue 7 163 141 0 - 255...
Z O N E L AY O U T S Please note that all zones are shown in default pixel flip configuration. FULL CONTROL, FULL RAW, AND PIXEL FOCUS ZONING CW Strobe RGB Zone RGB Zone CW Strobe RGB StrobeLine CW Strobe RGB Zone RGB Zone...
P R I M A R Y- S E C O N D A R Y S E T U P This function allows you to link units together to run in a Primary-Secondary set-up, in which one unit will act as the controlling unit and the others will react to the controlling unit’s built-in programs.
M U LT I U N I T P O W E R L I N K I N G This features allows you to connect the fixtures to one another using the power cable input and output sockets. The maximum number of units that can be linked in this manner is as follows: •...
T O R Q U E S E T T I N G S F O R S C R E W S IN ORDER TO MAINTAIN THE IP65 RATING ON THE LIGHTING FIXTURES, ALL SCREWS MUST BE TIGHTENED TO THE FOLLOWING TORQUE SPECIFICATION USING A TORQUE DRIVER.
Following any repair or maintenance procedure that requires disassembly of the fixture, use Elation’s IP Tester to confirm the IP integrity of the fixture. The air valve is located on the back panel next to the display screen, as shown in the diagram below. Please contact Elation...
E R R O R C O D E S Error Codes subject to change without notice ERROR CODES DESCRIPTION LEDTemp LED Temperature Error BaseTemp Fixture Base Temperature Error CoolFan1 Cooling Fan 1 Error CoolFan2 Cooling Fan 2 Error CoolFan3 Cooling Fan 3 Error CoolFan4 Cooling Fan 4 Error...
D I M E N S I O N A L D R AW I N G S 7.1in (180mm) 10.0in (255mm) 12.4in (314mm) 16.5in (420mm) 7.1in (181.3mm) 7.1in (180mm) 11.8in (299.3mm) 14.9in (378mm) 6.2in (156.5mm) 7.1in (181.3mm) 6.3in (159.3mm)
CE | cETLus(pend) | UL | IP65c| FCC | UKCA Variable Dimming Modes and Curves COLOR RGB Color Array O R D E R I N G I N F O R M AT I O N SKU (US) SKU (EU) ITEM DESCRIPTION PUL001 1237000343 Elation Pulse Panel...
F C C S TAT E M E N T This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Need help?
Do you have a question about the PULSE PANEL and is the answer not in the manual?
Questions and answers