Load-Bearing Foundation; Floor Plate; Existing Chimney And Pre-Fabricated Element Chimney; Connection Between Stove And Steel Chimney - SCAN 1004-B Assembly And Instruction Manual

Wood-burning stove
Table of Contents

Advertisement

LOAD-BEARING FOUNDATION

All items in our product range come under the category of lightweight fireplaces and stoves and do not normally require any
reinforcement of the beam structure. They can be positioned on ordinary beams/floor.
You should of course make sure that the foundation on which the stove is positioned can indeed support the weight of the stove
and, where applicable, a steel chimney, if you have opted for this solution. In case of doubt about the carrying capacity of the
floor, please consult a building expert.

FLOOR PLATE

If you are placing the stove on a flammable floor, you must comply with the national and local regulations on the size of any
non-flammable subsurface required to cover the floor around the stove.
Your local Scan dealer can advise you on regulations concerning protection of flammable materials in the vicinity of your stove.
The floor plate's function is to protect the floor and flammable material against any sparks that may occur.

EXISTING CHIMNEY AND PRE-FABRICATED ELEMENT CHIMNEY

If you intend to connect your stove to an existing chimney, it makes sense to contact an authorised Scan dealer, or a local chim-
ney sweep, for advice. These experts will also let you know if your chimney needs renovating.
¬
When connecting a pre-fabricated element chimney, follow the manufacturer's connection instructions for the relevant
chimney type

CONNECTION BETWEEN STOVE AND STEEL CHIMNEY

Your Scan dealer, or local chimney sweep, can advise you on choosing a make and type of steel chimney. This ensures that the
chimney will match your wood-burning stove.

REQUIREMENTS FOR CHIMNEY

The chimney must have a diameter of min. 148 mm and be labelled T400 and G for soot testing. The length should be min.
4,5 metres.
If you opt to connect the stove with an elbow pipe, you should use a curved elbow, as this gives a better draught.
If you connect the stove with a sharp elbow pipe, the cleansing lid must be placed in the vertical part so that the horizontal part
can be cleaned through here.
If the chimney is fitted with a smoke extractor, it must be possible to adjust it to a suitable draft.
The requirements to the chimney and the flue pipe in terms of safety distances must be met.
¬
Choosing the wrong length or diameter of chimney could impair functionality
¬
Always comply exactly with the instructions provided by the chimney supplier
Curved elbow pipe
Scan 1010
NAVN:
MATERIALE:
DIMENSION:
NAVN:
opstilling med knærør
EMNE:
MATERIALE:
N/A
25-08-2016
VÆGT:
DATO:
M3 NR.:
N/A
AREAL:
Krog Iversen & Co A/S
STI:
Sharp elbow pipe
ovn med 90 gr røgrør
Scan 1010
EMNE:
TG.NR:
91010042
hms
SIGN:
N/A
DIM.:
AREAL:
C:\Working Folder\Designs\Scan 1010\91010046.idw
TG.NR:
91010046
N/A
21-09-2016
hms
VÆGT:
DATO:
SIGN:
Scan A/S
DK-5492 Vissenbjerg©