Download Print this page

Functions; Technical Data - sauter TB-US Instruction Manual

Ultrasonic material thickness gauge

Advertisement

Attention: The model TB 200-0.1US-red has no freely selectable measuring range.
The stored materials can be measured. Therefore please read the relevant sections
only.
Note: It is strongly recommended to calibrate the new instrument before first
use. This will result in a higher measurement accuracy from the beginning.

1. Functions

• Wide measuring range and high resolution
• Suitable for measuring the material thickness of many materials, e.g. steel, cast
iron, aluminium, copper, brass, zinc, quartz glass, polyethylene, PVC, grey cast
iron, nodular cast iron.
• Automatic shutdown function to maintain power.

2. Technical data

Display
Measuring range
Resolution
Measurement
uncertainty
Sound velocity
Ambient temperature
Humidity
Power supply
Size
Weight
3. Scope of delivery:
• Transport case
• Operating instructions
• Ultrasonic sensor
• Ultrasonic contact gel
• 4x 1.5V AA batteries
TB_US-BA-e-2020
TB-US
4 digits, 10mm LCD display
1.5-200mm (45# steel)
0.1mm / 0.001 inch
±0,5% n +0,1
500-9000m/s
0-50°C
≤80%
4x 1.5V AA (UM-3) batteries
160x68x32mm
Approx. 210g (without batteries)
TB-US-red
3