Item
Temperature/
Operating
Humidity
Storage
(Factory packing)
Elevation
Acoustic noise
5 to 40°C {41 to 104°F}, 10 to 90 %RH
(See the operating temperature and humidity range below.)
-10 to 50°C {14 to 122°F}, 10 to 90 %RH (except for paper)
[%RH]
90
31°C, 90%
34°C, 75%
Operating environment
range
10
5
Ambient temperature
3000 m or less
When printing: 55 dB
When standby: 42 dB
Note:
The values above are measured in the Epson evaluation condition.
Acoustic noise differs depending on the paper used, printing contents, and the
setting values, such as print speed or print density.
Product Specifications
Specification
34°C, 90%
40°C, 65%
40°C, 43%
Specified original paper other than
below
Specified original paper:
P30521, P30523, P31523, P35524
34 40