14 Default values and settings

14
Default values and settings
Pump type – Boiler controlled pump
Boiler control temperature
Switch off temperature
Outdoor sensor min power
Outdoor sensor max power
Boiler power rating
PWM pump
DHW set temperature
DHW hysteresis
Accumulator set temperature
Accumulator hysteresis
Pump on temp (accumulator mode)
Default
Energy-efficient
70 °C
76 °C
8 °C
2 °C
16/20/25/32
70 %
50 °C
15 °C
30 °C
5
40 °C
Minimum
Maximum
-
70 °C
90 °C
76 °C
95 °C
7 °C
25 °C
-10 °C
6 °C
10/21 kW
20/32 kW
30 %
100 %
30 °C
75 °C
5 °C
20 °C
30 °C
75 °C
5
20
10 °C
80 °C