13 Controller for heating circuits and DHW
Adjusting the time programme of the boiler.
By pressing
the start and stoptime appear.
Activate the times with
In the activated time, the boiler always runs up to
the switch-off temperature without considering the
contact Z26. Outside the time, the contact Z26
activates the boiler.
Setting Outertemperature control.
Here you can set the temperature values for the
maximum and minimum boiler rating.
Adjustment range max. rated power -10° C bis +6°
C
Adjustment range min. power +7° C bis +25° C
Setting boiler rated power.
Enter the desired rated output of the boiler to
make a more accurate setting. This will improve
boiler runtime and modulation.
Settings pumptype:
Z16/38
Heating efficient with or without PWM1 - PWM
signal heating
Asynchronus pump – direct output 230VAC
on/off
Heating efficient PWM 2 – PWM signal solar