IEC Hazardous Location Approval
The following applies to products with IECEx certification:
• Such modules are intended for use in areas in which explosive atmospheres caused by gases, vapors, mists, or air are unlikely to occur, or are likely to occur only infrequently and for short periods.
Such locations correspond to Zone 2 classification to IEC 60079-0.
• Such modules may have catalog numbers followed by a "K" to indicate a conformal coating option.
• The type of protection for 1756-PB50, 1756-PB72, 1756-PB75, 1756-PBXT, and 1756-PB30XT, is "Ex nA IIC T4 Gc" according to IEC 60079-15.
• The 1756-PB50, 1756-PB72, 1756-PB75, 1756-PBXT, and 1756-PB30XT comply to Standards IEC 60079-0:2011, IEC 60079-15:2010, reference IECEx certificate number IECExUL14.0008X.
ATEX and IECEx Hazardous Location Conformity
Model
1756-PA50, 1756-PA50K
1756-PA72, 1756-PA72K
1756-PA75, 1756-PA75K
1756-PB50, 1756-PB50K
1756-PB72, 1756-PB72K
1756-PB75, 1756-PB75K
1756-PC75
1756-PH75, 1756-PH75K
1756-PAXT
1756-PBXT
1756-PA30XT
1756-PB30XT
Waste Electrical and Electronic Equipment (WEEE)
At the end of its life, this equipment should be collected separately from any unsorted municipal waste.
Special Conditions for Safe Use
WARNING:
• This equipment shall be mounted in an ATEX/IECEx Zone 2-certified enclosure with a minimum ingress protection rating of at least IP54 (as defined in
EN/IEC 60529) and used in an environment of not more than Pollution Degree 2 (as defined in EN/IEC 60664-1) when applied in Zone 2 environments.
The enclosure must be accessible only by the use of a tool.
• This equipment shall be used within its specified ratings defined by Rockwell Automation.
• Provision shall be made to prevent the rated voltage from being exceeded by transient disturbances of more than 140% of the rated voltage when applied in
Zone 2 environments.
• This equipment must be used only with ATEX/IECEx certified Rockwell Automation backplanes.
• Instructions in the user manual shall be observed.
• Secure any external connections that mate to this equipment by using screws, sliding latches, threaded connectors, or other means provided with this
product.
• Do not disconnect equipment unless power has been removed or the area is known to be nonhazardous.
• Devices shall be used in an environment of not more than Pollution Degree 2.

Summary of Changes

We updated the torque requirement on pages
Protection Type
None
None
None
Ex nA IIC T4 Gc
Ex nA IIC T4 Gc
Ex nA IIC T4 Gc
None
None
None
Ex nA IIC T4 Gc
None
Ex nA IIC T4 Gc
7
and
10
for these power supplies.
Rockwell Automation Publication 1756-IN619E-EN-P - September 2019
ATEX Certificate
DEMKO13ATEX1325026X
DEMKO13ATEX1325026X
DEMKO13ATEX1325026X
DEMKO13ATEX1325026X
DEMKO13ATEX1325026X
ControlLogix Power Supply
IECEx Certificate
IECEx UL 14.0008X
IECEx UL 14.0008X
IECEx UL 14.0008X
IECEx UL 14.0008X
IECEx UL 14.0008X