Attribute
Voltage and current ratings
Output (current capacity) 1.75 A, 24V DC,
Isolation voltage
Temperature, operating
IEC 60068-2-1 (Test Ad, Operating Cold),
IEC 60068-2-2 (Test Bd, Operating Dry Heat),
IEC 60068-2-14 (Test Nb, Operating Thermal Shock)
Temperature, surrounding air, max
Enclosure type rating
Torque
Dimensions (HxWxD), approx
Wire size
North American temperature code
ATEX temperature code
IECEx temperature code

Additional Resources

These documents contain additional information concerning related products from Rockwell Automation.
Resource
1756 ControlLogix Specifications Technical Data, publication
1756 ControlLogix Power Supplies Specifications Technical Data, publication
ControlLogix Chassis Installation Instructions, publication
ControlLogix System User Manual, publication
Industrial Automation Wiring and Grounding Guidelines, publication
Product Certifications website,
http://www.rockwellautomation.com/rockwellautomation/certification/overview.page
You can view or download publications at http://www.rockwellautomation.com/literature/. To order paper copies of technical documentation,
contact your local Allen-Bradley distributor or Rockwell Automation sales representative.
1756-PAXT
Input
120/240V AC, 50/60 Hz, 82VA,
64 W
8.0 A, 5.1V DC,
4.0 A, 3.3V DC,
1.5 A, 1.2V DC,
42 W max,
20 A inrush max
250V (continuous), Reinforced Insulation Type, Power Input to Backplane
-25 °C < Ta < +70 °C (-13 °F < Ta < +158 °F)
70 °C (158 °F)
None (open-style)
0.565 N•m (5 lb•in)
14.0 x 11.2 x 14.5 cm (5.51 x 4.41 x 5.71 in.)
2.5 mm2 (14 AWG) solid or stranded copper wire rated at 90 °C (194 °F), or greater, 1.2 mm (3/64 in.) insulation max
T4
-
-
1756-TD006
1756-TD005
1756-IN621
1756-UM001
1770-4.1
Rockwell Automation Publication 1756-IN619E-EN-P - September 2019
1756-PBXT
1756-PA30XT
18...32V DC, 70 W
120/240V AC, 50/60 Hz, 50 W
(60VA), 70 °C (158 °F)
2.1 A, 24V DC,
1.25 A, 24V DC;
10.0 A, 5.1V DC,
6.0 A, 5.1V DC;
4.0 A, 3.3V DC,
2.0 A, 3.3V DC;
1.5 A, 1.2V DC,
1.5 A, 1.2V DC;
52 W max,
30 W max,
30 A inrush max
20 A inrush max
14.0 x 7.8 x 14.5 cm (5.51 x 3.07 x 5.71 in.)
T4A
T4
T4
-
T4
-
Description
Provides technical specifications for ControlLogix chassis.
Provides technical specifications for ControlLogix power supplies.
Provides information on how to install ControlLogix chassis.
Provides instructions for installation and use of ControlLogix Systems, application design, and other
general information for these systems.
Provides general guidelines for installing a Rockwell Automation industrial system.
Provides declarations of conformity, certificates, and other certification details.
ControlLogix Power Supply
1756-PB30XT
24V DC, 50W 70 °C (158 °F)
1.25 A, 24V DC;
6.0 A, 5.1V DC;
2.0 A, 3.3V DC;
1.5 A, 1.2V DC;
30 W max,
20 A inrush max
T4
T4