5.2. Functions available from control module
The control module displays use parameters and their settings, which can be changed using the four
buttons on the front panel.
2
2
1
1
The operator has access to menus from A to H and to a cleaning screen.
• A : Powder flow rate adjustment and selection of pre-set characteristics (U/I).
• B : Dilution air adjustment and selection of pre-set characteristics (U/I).
• C : Manual adjustment (voltage/current).
• D : History of faults encountered (accessible only if a fault is recorded).
• E: Screen adjustment (contrast, etc.) and indication of Mach Jet version.
• F: Unit configuration; either vibrating table or fluidisation tank (only in the case of using a carriage).
• G: Configuration with computer link (only in the case of a manual unit connected to an industrial
PLC).
• H: Choice for the type of the characteristics U/I 1 or U/I 2.
• Cleaning screen / Standby screen.
Area 1: The front panel of the module has four buttons.
A graphic icon located above each button indicates the button's purpose.
Area 2: This display area indicates parameter status.
For example: For screen A, the powder flow rate is set at 9. The cloud at the spray gun outlet is partially
filled (9/12) and the pre-programmed characteristic is that of the round spray nozzle.
Area 3: The bar graph located in this area shows the instant voltage and current values in graphic and
digital form.
Area 4: A screen entitled "Main" appears on start-up. It is identified by an icon located at the top right-
hand side of the screen.
Without PLC: The graphic icon [V])appears under the menu index. This description corresponds to
the type of powder supply; two are possible:
• [V]: Use of vibrating table (parameter indicated by default, factory setting).
• [F]: Use of fluidisation tank.
(This choice can be made at any time by going to the "F" menu).
If this logo appears under [V], it indicates that the generator has shut down because of a fault
(see § 6.8.1 page
When the trigger is pressed, this logo flashes (the arrow indicates presence of high voltage at the
bottom of area 4).
Index revision : H
CRN 457 control module front panel
.
24).
1
15
4
4
3
3
6336