Translation of the original operating instructions
XL Sniffer Adapter Set
Catalog no.
from software version
Document no.
560-319
Control unit 2.11
MSB 2.11
jinxa54en1-03

Advertisement

Table of Contents
loading

Summary of Contents for Inficon XL Sniffer Adapter Set

  • Page 1 Translation of the original operating instructions XL Sniffer Adapter Set Catalog no. 560-319 Control unit 2.11 from software version MSB 2.11  jinxa54en1-03 Document no.
  • Page 2 This document applies to the software version stated on the title page. Documents for other software versions are available from our sales department. Reprinting, translation, and duplication require written confirmation from INFICON GmbH.
  • Page 3: Table Of Contents

    XL Sniffer Adapter Set ........
  • Page 4 Decommissioning the device ....27 XL Sniffer Adapter set disposal ......27 Sending the XL Sniffer Adapter Set to INFICON .
  • Page 5: About These Instructions

    About these instructions Target groups These operating instructions are intended for the owner and for technically qualified personnel with experience in leak detection technology and integration of leak detec- tion devices in leak detection systems. In addition, the installation and use of the unit require knowledge of electronic interfaces.
  • Page 6 Marking Meaning ► Instruction 1, 2, 3, ... Several instructions in a fixed order  Result of an action About these instructions...
  • Page 7: Safety

    Safety Intended use The XL Sniffer Adapter supplements the mass spectrometer module LDS3000. With this addition, mass spectrometer module LDS3000 can be used as a sniffer leak de- tector in low flow or high flow. This combination makes it possible to capture leaks at a larger distance from the expected leak if the detection limit is deteriorated.
  • Page 8: General Safety Information

    General safety information The unit was built according to the state of the art and the recognized safety regula- tions. Nevertheless, improper use may result in risk to life and limb on the part of the user or third parties, or damage to the unit or other property may occur. Electric power The device is operated with electrical voltages of up to 24 V.
  • Page 9: Shipment, Transport, Storage

    Shipment, Transport, Storage Shipment Item Quantity XL Sniffer Adapter GROSS throttle flange FINE throttle flange Replacement filter cartridge Cable kit, comprising three cables Operating instructions, printed USB stick with instructions, software The cable kit contains – a replacement cable (200005089) that replaces the previous connection be- tween MSB box, turbo molecular pump and the fan.
  • Page 10: Description

    Description Function The XL Sniffer Adapter set amends the LDS3000. With the XL Sniffer Adapter set, even small leaks can be detected from a great distance. The best detection limit is achieved in low flow. Switching to high flow achieves a better distance sensitivity while the detection limit is made worse.
  • Page 11: Xl Sniffer Adapter

    The sniffer line belonging to the XL Sniffer Adapter is the SL3000XL. FINE throttle flange The FINE throttle flange is on the "FINE Sniffer" connection and is the connection to the LOW FLOW connection of the XL Sniffer Adapter. It also includes the connection to the FINE input of the backing pump.
  • Page 12 Fig. 3 XL Sniffer Adapter - Rear view Hose connection "HIGH FLOW", hose connection to the "HIGH FLOW" connection of the backing pump Hose connection "LOW FLOW", hose connection to the filter on the FINE throttle flange Connection A, RJ45. This connection is used to supply the XL Sniffer Adapter with voltage and connect the internal pressure sensor with the MSB box.
  • Page 13: Fine Throttle Flange

    FINE throttle flange Fig. 4 FINE throttle flange for the connection to the LDS3000 Hose connection to the FINE connection of the backing pump  Union nut for filter with hose connection to the low flow connection on the XL Sniffer Adapter Flange connection to the FINE connection of the connection block on the LDS3000 GROSS throttle flange Fig.
  • Page 14: Backing Pump

    Backing pump The backing pump can be ordered from Inficon by catalog no. 560-330. Fig. 6 Backing pump Hose connection high flow. Hose connection to the "HIGH FLOW" connection of the XL Sniffer Adapter Hose connection GROSS. Hose connection to GROSS throttle flange on the LDS3000 Hose connection Fine.
  • Page 15: Sniffer Line Sl3000Xl

    Sniffer line SL3000XL 4.7.1 Operating elements on the handle The display of the handle displays part of the information of the main display. Fig. 7 Sniffer line SL3000XL The leak rate is shown as a bar graph and displayed numerically. The unit of mea- surement is the same as in the main display.
  • Page 16: Technical Data

    Technical data 4.8.1 Mechanical data Dimensions XL Sniffer Adapter (W x H x D) 106.2 mm x 128.4 mm x 49.2 mm Weight XL Sniffer Adapter 500 g 4.8.2 Physical data   Gas flow – High Flow 3000 sccm –...
  • Page 17 Parameters Factory setting Display off after 1h (= 1 hour) Display brightness 100% Measurement view mode Diagram Audio alarm mode Proportional Auto scale Data record Decades Pressure unit of the display mbar Favorite 1 Volume Favorite 2 Measurement view mode Favorite 3 Error info Operator No.
  • Page 18: Installation

    Installation The XL Sniffer Adapter set is installed in the immediate vicinity of the LDS3000 (40 cm). A suitable holding fixture must be provided by the operator. Sufficient ventilation must be ensured for a closed housing. Fig. 8 Assembly of the components...
  • Page 19: Xl Sniffer Adapter Assembling

    XL Sniffer Adapter assembling 106,2 (4.18) (4.06) 91,4 (3.6) Fig. 9 Dimensions of the adapter front panel in mm (inches in brackets) 1 Position the XL Sniffer Adapter inside the holding fixture. 2 Fix the XL Sniffer Adapter in place using suitable mounting screws. Mounting the backing pump Please refer to the backing pump operating and installation instructions for informa- tion on the assembly of the KNF backing pump.
  • Page 20: Installing The Gross Throttle Flange On The Connection Block

    Creating hose connections See also Fig. 1:„Connection diagram of XL Sniffer Adapter set, LDS3000, backing pump, PSG500“ auf Seite ► Connect the "HIGH FLOW" output of the XL Sniffer Adapter with "XL HIGH FLOW" input of the backing pump.
  • Page 21 Fig. 10 Cable tie to open 2 Release and pull off the SUB-D plugs on the converter of the turbo molecular pump and on the MSB box (connection "2"). 3 Release and pull off the plug on the fan. Fig. 11 The three plugs of the cable to replace Installation...
  • Page 22: Connecting The Sl3000Xl Sniffer Line

    5.9.2 Checking and updating the software version of the MSB box The functions of the XL Sniffer Adapter Set are taken into consideration in the soft- ware version 2.11 or higher. The current software is available from the INFICON support.
  • Page 23: Updating The Software Of Control Unit Cu1000

    2 Select the main menu:  "Functions > Data > Update > MSB"  The display shows information on the current and the new software version as well as on the boot loader. 3 Check the version information. 4 Press "Start" to begin the update and confirm the prompt with "OK". 5 If the system issues warning 106, confirm this with "C".
  • Page 24: Operation

    Operation The operating setting for the XL Sniffer Adapter are based on the settings for the sniffer line without adapter. The special features and the settings for the XL Sniffer Adapter are therefore described in the operating instructions for the LDS3000 (doc- ument jiqa54).
  • Page 25: Maintenance

    Maintenance Indication of the next maintenance interval and  total operating time You can read-out when the next maintenance interval is and the total operating time of the individual components. 1 Select the main menu: "Info > History > Maintenance" ...
  • Page 26: Replacing The Filter On The Fine Throttle Flange

    Fig. 13 Filter cartridge 3 Put the sniffer probe on the handle and tighten the cap nut manually only. ► Check for tightness: If air cannot be sucked in, the LDS3000 issues warning W41. If the end the sniffer probe is closed and the warning was not issued, then the screw connection on the sniffer probe is leaking or the filter cartridge is not positioned correct.
  • Page 27: Decommissioning The Device

    Decommissioning the device XL Sniffer Adapter set disposal The operator can dispose of the unit or it can be sent to INFICON. The unit consists of materials that can be recycled. You should use this option to avoid waste and save the environment.
  • Page 28: Declaration Of Contamination

    Declaration of Contamination Decommissioning the device...
  • Page 29: Declaration Of Incorporation

    Declaration of Incorporation Declaration of Incorporation...