INSTALLATION
WARNING: In all circumstances, make sure the cooktop is well ventilated and
the air intakes and outlets are not blocked. DO NOT install the cooktop if glass is
cracked or any other damaged noticeable.
The safety distance between the cooktop and the cupboard above the cooktop
should be at least 760mm. Any rangehood installed above the cooktop should be
no less than 650mm above the surface of the cooktop. Be aware that due to the
nature of Induction cooktops excessive condensation may be present especially in
the colder months or climates.
NOTE: If the cooktop is installed above an opening drawer or cupboard a thermal
protection heat barrier MUST BE fitted 50mm below the base of the underside of
the cooktop to avoid possibly scalding when accessing the drawer or cupboard.
Refer to the below illustration and table re other ventilation and clearance.
A(mm)
760
Note: This dimension relates to adjoining cupboards. For a rangehood installed
above the cooktop the minimum distance is 650mm from cooktop surface highest
point to the bottom of the rangehood filters.
B(mm)
C(mm)
50 mini
20 mini
Air intake
28
D
E
Air exit 5mm