Command 16: Read Final Assembly Number; Command 17: Write Message; Command 18: Write Tag, Descriptor, Date - Bell VFM60 Series User Introduction Manual

Vortex flowmeter
Table of Contents

Advertisement

7.1.11 Command 16: Read final assembly number

Command formate:
Read final assembly number.
Request:
None
Response:
Byte 0-2:
Test of command:
Send command 16:FF FF FF FF FF 82 9A 1A AD 18 8C 10 00 2B; Read final assembly number
Receive command 16: FF FF FF FF FF 86 9A 1A AD 18 8C 10 05 00 00 A8 36 81 35

7.1.12 Command 17: Write message

Command formate:
Write message
Request:
Byte 0-23: Message
Responee:
Byte 0-23: Message
Test of command:
Send command 17:FF FF FF FF FF 82 9A 1A AD 18 8C 11 18 00 01 02 03 04 05 06 07 08 09 0A
0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 32 ;message
Receive command 17:FF FF FF FF FF 86 9A 1A AD 18 8C 11 1A 00 00 00 01 02 03 04 05 06 07
08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 34

7.1.13 Command 18: Write tag, descriptor, date

Command formate:
Write tag, descriptor, date.
Request:
Byte 0-5:
Byte 6-17:
Byte 18-20: Date: day, month, year
Response:
Byte 0-5:
Byte 6-17:
Byte 18-20: Date: day, month, year
Test of command:
Send command 18: FF FF FF FF FF 82 9A 1A AD 18 8C 12 15 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 3C
Date:24/04/2020
Final assembly number
Tag,ASCII
Descriptor,ASCII
Tag,ASCII
Descriptor,ASCII
39 / 59