Bell VFM60 Series User Introduction Manual page 16

Vortex flowmeter
Table of Contents

Advertisement

The LCD display has 2 areas to display the content, the upper row, the lower row. The upper
row displays the flow rate/mass flow/standard flow rate. Below the upper row shows the unit of the
variable displayed in upper row.
The lower row display indicates other variables, such as requency/ pressure/ temperature/ density/
total flow/ velocity. And below the lower row shows the unit of the variable displayed in lower row.
Please reference to picture 4.2 for display
VFM60 multi-varibale version or normal version with temperature and pressure compensation, can
calculate and display the mass flow of steam, both saturated steam and superheated steam. Please
reference to picture 4.3 for mass flow rate displaying.
VFM60 multi-variable version or normal version with temperature and pressure compensation can
display variables such as temperature/ pressure/ density. Use the switch buton to switch to next variable
and it will display for 30 seconds.
Date:24/04/2020
Picture 4.1 LCD display
Picture 4.2 Flow rate and total flow
Picture 4.3 Mass flow and total flow of steam displaying
16 / 59
VFM-60
Vortex Flowmeter
Rev1.3
User's Manual

Advertisement