According to picture 4.6 and 4.7, the total flow is 569864.581 kg.

4.5 Status

VFM60 series vortex flowmeter have three different statuses as below
Working status
Setting status
Calibration status
When under working status, please follow the instruction in 4.1 to switch the parameter displayed.
When under setting status, you can set the flowmeter, while the flowmeter is still processing, so setting
will not have effect on the measuring. In next chapter, there will be instruction of how to do setting.
The calibration of the flowmeter has been finished in manufacture's lab before delivery, including
temperature and pressure calibration and the setting of high-limit and low-limit of 4~20mA stimulation
output. Thus, customers do not to set any more.

5 Setting

Note: Every VFM60 digital vortex flowmeters has been set according to requirement before
delivery, please do not change setting unless it is necessary and under correct instruction!
VFM60 series digital vortex flowmeter have digigal setting and code setting. Use code setting to
set parameters such as fluid type, compensation type and output signal. Use digital setting to set
parameters related to a number, such as pipe size, flow range, factor.

5.1 How to set

5.1.1 Code setting

Under working status, to enter code setting, please hold "Enter button" then press "U-D button" at the
Date:24/04/2020
Picture 4.7 Displaying the right digits