Austroflamm 65x Operating Manual

Austroflamm 65x Operating Manual

Fireplac inserts slied flat + ii
Hide thumbs Also See for 65x:
Table of Contents

Advertisement

Quick Links

65x / 75x / 75x39 SII / 75x51 SII
80x64 / 80x64 SII
97x / 120x45
Operating manual
Fireplac inserts slied flat + II
www.austroflamm.com

Advertisement

Table of Contents
loading

Summary of Contents for Austroflamm 65x

  • Page 1 65x / 75x / 75x39 SII / 75x51 SII 80x64 / 80x64 SII 97x / 120x45 Operating manual Fireplac inserts slied flat + II www.austroflamm.com...
  • Page 2 Tel: +43 (0) 7249 / 46 443 www.austroflamm.com info@austroflamm.com Edited by: Olivera Stojanovic Illustrations: Konstruktion Text: Technical department (Austroflamm) Copyright All Rights reserved. The contents of these instructions may be reproduced or distributed only with the consent of the publisher! Printing, spelling and typographical errors reserved.
  • Page 3: Table Of Contents

    Operating manual Fireplac inserts slied flat + II Contents Contents General information ............................Copyright.............................. Regulations to be observed ....................... Purpose of the operating manual........................Storing the operating manual ......................Structure of the operating manual ....................Representations used.......................... Version control............................. Abbreviations ............................Safety ..................................
  • Page 4 Contents Operating manual Fireplac inserts slied flat + II Multiple occupancy ..........................44 Flue pipe connecting pieces......................44 Fuel material/-quantity ............................45 Fuel material............................45 Fuel quantity............................47 Installation instructions ............................48 Set-up in front of or next to a wall to be protected ................. 48 Convection air cladding........................
  • Page 5 Operating manual Fireplac inserts slied flat + II Contents 13.1 Initial Commissioning.......................... 91 14 Operation................................92 14.1 Controls..............................92 14.2 Before heating up..........................92 14.3 Fuel ................................ 93 14.4 Firing ..............................93 14.5 Heating..............................94 14.6 Putting on wood ..........................94 14.7 Heating in the transition period......................
  • Page 6: General Information

    Operating manual Fireplac inserts slied flat + II General information You have decided in favour of an Austroflamm fireplace insert. Congratulations on your decision and thank you for your trust. Correct operation and care are essential for trouble-free operation and long service life. Likewise, please follow the instructions in the operating manual.
  • Page 7: Regulations To Be Observed

    Operating manual Fireplac inserts slied flat + II 1 | General information Regulations to be observed • EN 13229 • DIN 18896 • DIN EN 13384 Part 1 and Part 2 • DIN 18160-1 Exhaust systems - Part 1 • EN 12831 •...
  • Page 8: Purpose Of The Operating Manual

    Storing the operating manual Store this manual in case you need it. The current version of the manual can be found on-line at our homepage www.austroflamm.com. Structure of the operating manual The table of contents can be found on page 3.
  • Page 9: Abbreviations

    Operating manual Fireplac inserts slied flat + II 2 | Purpose of the operating manual Abbreviations Abbreviation Meaning Heat Memory System Fireplace insert Ceramic flue Convection cladding...
  • Page 10: Safety

    3 | Safety Operating manual Fireplac inserts slied flat + II Safety In this manual we give you numerous safety instructions for the safe operation of your fireplace insert. These instructions are characterized differently as follows, depending on their importance: Importance of the safety instructions NOTICE Particular behaviour and/or activities that are required for safe working.
  • Page 11: Special Types Of Danger And Personal Protective Equipment

    Operating manual Fireplac inserts slied flat + II 3 | Safety Special types of danger and personal protective equipment For certain activities such as installation/dismantling, particular care must be taken that the following safety equipment is worn: Safety gloves Safety shoes...
  • Page 12: Product Overview

    Operating manual Fireplac inserts slied flat + II Product overview Intended use The Austroflamm fireplace inserts described in this manual are manufactured and tested with a type A1 self-closing and locking door under EN test EN 13229. NOTICE Operation is only permissible with the door closed.
  • Page 13 Operating manual Fireplac inserts slied flat + II 4 | Product overview 75x39/51 SII 2.0 Width (body installation dimension) [mm] Door frame, height [mm] 390/510 Pane curvature straight on both sides Width [mm] Depth [mm] Height [mm] 1123-1323 / 1284-1484 Weight [kg] 186/202 Nominal heat efficiency [kW]...
  • Page 14: Positioning Of The Nameplates

    4 | Product overview Operating manual Fireplac inserts slied flat + II 4.2.2 Positioning of the nameplates Here we show where you can find the nameplate. You received a copy of the nameplate with the fire- place insert. You can find a copy of the nameplate of your fireplace insert on the back of the manual you get with your fireplace insert.
  • Page 15: Technical Data

    Technical data Technical data under Directive (EU) 2015/1185 and del. as per Regulation (EN) 2015/1186 5.1.1 65x51-S-2.0 Contact details for the manufacturer or their authorized representative Manufacturer: Austroflamm GmbH Contact: Address: Austroflamm-Platz 1 4631 Krenglbach Austria Appliance details Model identification(s): 65x51-S-2.0...
  • Page 16 5 | Technical data Operating manual Fireplac inserts slied flat + II Lignite briquettes Peat briquettes Briquettes made from a mixture of fossil fuels Other fossil fuels Briquettes made from a mixture of biomass and fossil fuels Other mixture of biomass and solid fuels (*) PM = dust, OGC = organic gaseous connections, CO = carbon monoxide, NOx = nitrogen oxide (**) Only required when using correction factors F(2) or F(3).
  • Page 17: 65X57-S-2.0

    2 and 3.) Specifications are made here for the preferred fuel only. 5.1.2 65x57-S-2.0 Contact details for the manufacturer or their authorized representative Manufacturer: Austroflamm GmbH Contact: Address: Austroflamm-Platz 1 4631 Krenglbach Austria Appliance details Model identification(s): 65x57-S-2.0...
  • Page 18 5 | Technical data Operating manual Fireplac inserts slied flat + II Peat briquettes Briquettes made from a mixture of fossil fuels Other fossil fuels Briquettes made from a mixture of biomass and fossil fuels Other mixture of biomass and solid fuels (*) PM = dust, OGC = organic gaseous connections, CO = carbon monoxide, NOx = nitrogen oxide (**) Only required when using correction factors F(2) or F(3).
  • Page 19: 75X39-S-2.0

    2 and 3.) Specifications are made here for the preferred fuel only. 5.1.3 75x39-S-2.0 Contact details for the manufacturer or their authorized representative Manufacturer: Austroflamm GmbH Contact: Address: Austroflamm-Platz 1 4631 Krenglbach Austria Appliance details Model identification(s): 75x39-S-2.0...
  • Page 20 5 | Technical data Operating manual Fireplac inserts slied flat + II Peat briquettes Briquettes made from a mixture of fossil fuels Other fossil fuels Briquettes made from a mixture of biomass and fossil fuels Other mixture of biomass and solid fuels (*) PM = dust, OGC = organic gaseous connections, CO = carbon monoxide, NOx = nitrogen oxide (**) Only required when using correction factors F(2) or F(3).
  • Page 21: 75X39-Sii-2.0

    2 and 3.) Specifications are made here for the preferred fuel only. 5.1.4 75x39-SII-2.0 Contact details for the manufacturer or their authorised representative Manufacturer: Austroflamm GmbH Contact: Address: Austroflamm-Platz 1 4631 Krenglbach Austria Appliance details Model identification(s): 75x39-SII-2.0...
  • Page 22 5 | Technical data Operating manual Fireplac inserts slied flat + II Peat briquettes Briquettes made from a mixture of fossil fuels Other fossil fuels Briquettes made from a mixture of biomass and fossil fuels Other mixture of biomass and solid fuels (*) PM = dust, OGC = organic gaseous connections, CO = carbon monoxide, NOx = nitrogen oxide (**) Only required when using correction factors F(2) or F(3).
  • Page 23: 75X57-S-2.0

    2 and 3.) Specifications are made here for the preferred fuel only. 5.1.5 75x57-S-2.0 Contact details for the manufacturer or their authorized representative Manufacturer: Austroflamm GmbH Contact: Address: Austroflamm-Platz 1 4631 Krenglbach Austria Appliance details Model identification(s): 75x57-S-2.0...
  • Page 24 5 | Technical data Operating manual Fireplac inserts slied flat + II Peat briquettes Briquettes made from a mixture of fossil fuels Other fossil fuels Briquettes made from a mixture of biomass and fossil fuels Other mixture of biomass and solid fuels (*) PM = dust, OGC = organic gaseous connections, CO = carbon monoxide, NOx = nitrogen oxide (**) Only required when using correction factors F(2) or F(3).
  • Page 25: 75X51-S-Ii-2.0

    2 and 3.) Specifications are made here for the preferred fuel only. 5.1.6 75x51-S-II-2.0 Contact details for the manufacturer or their authorized representative Manufacturer: Austroflamm GmbH Contact: Address: Austroflamm-Platz 1 4631 Krenglbach Austria Appliance details Model identification(s): 75x51-S-II-2.0...
  • Page 26 5 | Technical data Operating manual Fireplac inserts slied flat + II Peat briquettes Briquettes made from a mixture of fossil fuels Other fossil fuels Briquettes made from a mixture of biomass and fossil fuels Other mixture of biomass and solid fuels (*) PM = dust, OGC = organic gaseous connections, CO = carbon monoxide, NOx = nitrogen oxide (**) Only required when using correction factors F(2) or F(3).
  • Page 27: 80X64-S-2.0

    2 and 3.) Specifications are made here for the preferred fuel only. 5.1.7 80x64-S-2.0 Contact details for the manufacturer or their authorised representative Manufacturer: Austroflamm GmbH Contact: Address: Austroflamm-Platz 1 4631 Krenglbach Austria Appliance details Model identification(s): 80x64-S-2.0...
  • Page 28 5 | Technical data Operating manual Fireplac inserts slied flat + II Peat briquettes Briquettes made from a mixture of fossil fuels Other fossil fuels Briquettes made from a mixture of biomass and fossil fuels Other mixture of biomass and solid fuels (*) PM = dust, OGC = organic gaseous connections, CO = carbon monoxide, NOx = nitrogen oxide (**) Only required when using correction factors F(2) or F(3).
  • Page 29: 80X64-S-Ii-2.0

    2 and 3.) Specifications are made here for the preferred fuel only. 5.1.8 80x64-S-II-2.0 Contact details for the manufacturer or their authorised representative Manufacturer: Austroflamm GmbH Contact: Address: Austroflamm-Platz 1 4631 Krenglbach Austria Appliance details Model identification(s): 80x64-S-II-2.0...
  • Page 30 5 | Technical data Operating manual Fireplac inserts slied flat + II Peat briquettes Briquettes made from a mixture of fossil fuels Other fossil fuels Briquettes made from a mixture of biomass and fossil fuels Other mixture of biomass and solid fuels (*) PM = dust, OGC = organic gaseous connections, CO = carbon monoxide, NOx = nitrogen oxide (**) Only required when using correction factors F(2) or F(3).
  • Page 31: 97X45-S

    2 and 3.) Specifications are made here for the preferred fuel only. 5.1.9 97x45-S Contact details for the manufacturer or their authorized representative Manufacturer: Austroflamm GmbH Contact: Address: Austroflamm-Platz 1 4631 Krenglbach Austria Appliance details...
  • Page 32 5 | Technical data Operating manual Fireplac inserts slied flat + II Peat briquettes Briquettes made from a mixture of fossil fuels Other fossil fuels Briquettes made from a mixture of biomass and fossil fuels Other mixture of biomass and solid fuels (*) PM = dust, OGC = organic gaseous connections, CO = carbon monoxide, NOx = nitrogen oxide (**) Only required when using correction factors F(2) or F(3).
  • Page 33: 97X74-S-2.0

    1) or g/kg for measurement in dilution tunnel (in compliance with Annexe III, number 4, let- ter a, section i, point 2 and 3.) Specifications are made here for the preferred fuel only. 5.1.10 97x74-S-2.0 Contact details for the manufacturer or their authorised representative Manufacturer: Austroflamm GmbH Contact: Address: Austroflamm-Platz 1 4631 Krenglbach Austria...
  • Page 34 5 | Technical data Operating manual Fireplac inserts slied flat + II Peat briquettes Briquettes made from a mixture of fossil fuels Other fossil fuels Briquettes made from a mixture of biomass and fossil fuels Other mixture of biomass and solid fuels (*) PM = dust, OGC = organic gaseous connections, CO = carbon monoxide, NOx = nitrogen oxide (**) Only required when using correction factors F(2) or F(3).
  • Page 35: 120X45-S-2.0

    1) or g/kg for measurement in dilution tunnel (in compliance with Annexe III, number 4, let- ter a, section i, point 2 and 3.) Specifications are made here for the preferred fuel only. 5.1.11 120x45-S-2.0 Contact details for the manufacturer or their authorized representative Manufacturer: Austroflamm GmbH Contact: Address: Austroflamm-Platz 1 4631 Krenglbach Austria...
  • Page 36 5 | Technical data Operating manual Fireplac inserts slied flat + II Peat briquettes Briquettes made from a mixture of fossil fuels Other fossil fuels Briquettes made from a mixture of biomass and fossil fuels Other mixture of biomass and solid fuels (*) PM = dust, OGC = organic gaseous connections, CO = carbon monoxide, NOx = nitrogen oxide (**) Only required when using correction factors F(2) or F(3).
  • Page 37: General Specifications

    1) or g/kg for measurement in dilution tunnel (in compliance with Annexe III, number 4, let- ter a, section i, point 2 and 3.) Specifications are made here for the preferred fuel only. General specifications Model 65x S 75x S 75x39 75x51 80x64 S...
  • Page 38 Hypocaust heating**) Suitable subject to technical rules *) under examination **) The Austroflamm appliances marked with “suitable subject to technical rules” are suitable for oper- ation in closed systems (hypocausts) ***) at the device connection at nominal heat efficiency The design of the hypocaust must ensure the transport of heat and the even distribution of heat within the cladding so that no part of the heating chamber can be overheated.
  • Page 39: Data For The Chimney/Flue Dimensioning

    Operating manual Fireplac inserts slied flat + II 5 | Technical data Data for the chimney/flue dimensioning Fireplace inserts with self-closing firebox doors. Description: Fireplace insert EN 13229 – A1 / A. For values see Technical data. When the draft is too great, the draft must be limited. Ensuring the correct draft is a matter for the stove/tiled stove builder.
  • Page 40: Transport And Storage

    6 | Transport and storage Operating manual Fireplac inserts slied flat + II Transport and storage Transportation Immediately checked the goods delivered for complete- ness and damage in transit. Before installing the fireplace insert, check that all movable parts are working. Any defects before the installation of the fireplace insert must be reported.
  • Page 41: Storage

    Operating manual Fireplac inserts slied flat + II 6 | Transport and storage Storage The fireplace insert must be stored in a dry room/warehouse. Protect against dirt, heat and moisture. The following illustrations are attached to the crate and must be observed: •...
  • Page 42: Requirements At The Installation Location

    Observe the guidelines on fire safety, such as thermal insulation and air grille sizes. DANGER Fire hazard Operating your Austroflamm fireplace insert with too high a fuel feed will create a risk of the chimney and adjacent components or furniture overheating. Combustion air supply For heat-producing appliances that draw their combustion air from the installation room an adequate supply of combustion air into the room must be provided.
  • Page 43: Combustion Air Duct

    (see state building regulations). Chimney requirements Before set-up or installation of the Austroflamm fireplace insert, the chimney must be checked for its size and quality under the existing local regulations (respectively state building regulations, heating regulations and DIN 18160, Part 1). The mathematical proof of the adequate function of the chimney must be provided in accordance with EN 13384.
  • Page 44: Multiple Occupancy

    Operating manual Fireplac inserts slied flat + II Multiple occupancy All Austroflamm fireplace inserts in this manual have been checked and approved under DIN EN 13229 with self-closing and locking door (designated BA1). Appliances intended to operate BA1 can be connected to a multiple-occupied chimney (if multiple occupancy is possible). The calculation is made according to DIN EN 13384 Part 2.
  • Page 45: Fuel Material/-Quantity

    Operating manual Fireplac inserts slied flat + II 8 | Fuel material/-quantity Fuel material/-quantity Fuel material Wood Many of our native types of wood can, after being appropriately dried, be burnt CO2-neutral in heat- producing appliances. Wood stands out because it grows again, can be sustainably harvested, re- quires little or no extra external energy to be invested in the fuel, and has a short journey from the pro- ducer to the consumer, which provides an optimal climate balance.
  • Page 46 8 | Fuel material/-quantity Operating manual Fireplac inserts slied flat + II Please observe at all times the maximum specified amount to be laid, even when putting on more wood! Otherwise your fire will not provide the desired efficiency - but above all considerable damage may be caused to your appliance, to gaskets and material and to the flue gas duct.
  • Page 47: Fuel Quantity

    Operating manual Fireplac inserts slied flat + II 8 | Fuel material/-quantity Approved fuel Dry, properly stored, unrefined log (preferably hard wood) is permitted as fuel for our hybrid stoves Round wood must be split at least once so that it lights better. The diameter of the split piece of wood must not exceed 7 cm.
  • Page 48: Installation Instructions

    9 | Installation instructions Operating manual Fireplac inserts slied flat + II Installation instructions NOTICE Damage to the appliance The fireplace insert must not have any connection to the housing (minimum gap width 3 mm), as oth- erwise damage may be caused to the appliance. Set-up in front of or next to a wall to be protected 9 10 Fig. 5: Set-up in front of/next to a wall to be protected...
  • Page 49 Operating manual Fireplac inserts slied flat + II 9 | Installation instructions Fig. 6: Set-up in front of/next to a wall to be protected Wall / building wall Thermal insulation layer (flue pipe) Connector Thermal insulation layer (rear panel) Convection room Exterior air intake Concrete slab at least 6 cm (only when being set Ceiling...
  • Page 50: Convection Air Cladding

    Operating manual Fireplac inserts slied flat + II Convection air cladding NOTICE When using CV cladding, please observe the national regulations in respect of individual room fire- places and the measurement requirement in the case of whole-home heating. 65x/75x Fig. 7: Casing 75x39 SII Fig. 8: Casing 80x64 S...
  • Page 51: Convection Space

    Operating manual Fireplac inserts slied flat + II 9 | Installation instructions Convection space • If the convection cladding (appliance part) is not used, a convection space of at least 6 cm depth between fire- place insert (4) and insulation layer (16) to the rear and on both sides must be allowed for.
  • Page 52: Fireplace System Without Air Grille (Hypocaust)

    9 | Installation instructions Operating manual Fireplac inserts slied flat + II Fireplace system without air grille (hypocaust) The convection air circulates within the closed cladding. The heat is emitted via radiation above the cladding. Protecting the installation base Installation bases (8) with flammable construction materials with a concrete slab (7) at least 6 cm thick (dimension E), which must be reinforced above installation bases without adequate lateral distribution, and above that by a thermal...
  • Page 53: Ceiling Above The Fireplace Insert

    Operating manual Fireplac inserts slied flat + II 9 | Installation instructions 9.11 Ceiling above the fireplace insert If the cavity above the fireplace insert reaches as far as the room ceiling (8), then the latter must be protected if: •...
  • Page 54 9 | Installation instructions Operating manual Fireplac inserts slied flat + II Insulation materials Delivery Insulation capacity Upper maximum applic- Bulk density ation temperature Group Type Group Type Group Type Group In °C Group kg/m³ Mineral fibre Channels Mats, -200 size 1 Glass fibre Fibres,...
  • Page 55: Electric Cable Runs

    Operating manual Fireplac inserts slied flat + II 9 | Installation instructions 9.15 Electric cable runs There must be no electric cable runs in walls and ceilings within the installation area of the fireplace in- sert. 9.16 Balanced flue-tested fireplace inserts Flue pipe connection •...
  • Page 56: Connection To Ceramic Flues

    Characteristics for calculating the flue dimensions Appliance type Exhaust gas mass flow [mg/s] Flue gas temperature at appli- Req’d Feed pressure at collar ance collar [°C] [Pa] 65x S 7.3 / 7.7 / 6.8 283 / 298 / 317 75x S 8.1/7.7...
  • Page 57: Stove With Ceramic Flue

    Operating manual Fireplac inserts slied flat + II 10 | Connection to ceramic flues Make the operator of the stove aware that the system with a downstream heat recovery surface must only be operated with the door closed! 10.1 Stove with ceramic flue Example using KMS system Example with CVC flue module...
  • Page 58: Connection To Heat Recovery Surfaces

    10 | Connection to ceramic flues Operating manual Fireplac inserts slied flat + II 10.2 Connection to heat recovery surfaces The specifications given in advance in respect of mounting instructions and installation regulations re- main valid (see distances, thermal insulation, exhaust pipe connection). The metallic heat exchanger can be placed to the left or right side or behind the fireplace insert.
  • Page 59: Installation

    Operating manual Fireplac inserts slied flat + II 11 | Installation Installation Installation must only be carried out by an authorized specialist company. Before installing the fireplace insert, check that all movable parts are working. Any defects before the installation of the fireplace insert must be reported. 11.1 Risks and dangers Schutzausrüstung The following protective equipment must be used:...
  • Page 60: Dismantling The Keramott

    11 | Installation Operating manual Fireplac inserts slied flat + II 11.2.2 Dismantling the Keramott There is only a Keramott lock for 65x51, 65x57, 75x39 and 75x57. 1) Open doors. Fig. 18: Opening the door 2) Remove Keramott support plate (1). 3) Remove left and right transport brackets (2).
  • Page 61: Installing The Firebox Lining (Keramott)

    11 | Installation 4) Install the deflector plates (1). Fig. 20: Install the deflector plates 11.2.3 Installing the firebox lining (Keramott) Keramott 65x, 75x Numbering = installation sequence Sequence for 75x39 SII and 75x51SII 1) Keramott floor 1 - 3 2) Keramott wall 4...
  • Page 62: Install The Deflector Plates

    Keramott 120x45S KII Numbering = installation sequence 11.2.4 Install the deflector plates The Keramott elements of the fire are already preinstalled. Only the Keramott deflections need to be installed. 65x, 75x S 1) Insert the baffle plate. Fig. 21: 65x, 75x S...
  • Page 63 Operating manual Fireplac inserts slied flat + II 11 | Installation 75x39/51 SII 2) First the two upper baffle plates (1+2) are inserted. These should be installed without spacing from each other. 3) Then the lower two bricks (3+4) are inserted as shown. ð...
  • Page 64: Removing The Door

    11.2.5.1 Flach sliding door appliances 2.0 (65x bis 75x / 80x64 / 97x45/74 / 120 x 45) For tunnel appliances, removal of the rear door is likewise according to the following instructions (with the exception of “Locking the door lift”).
  • Page 65: Converting Door To Construction Type Ba2

    Operating manual Fireplac inserts slied flat + II 11 | Installation 4) Do not prop the door. Fig. 29: Do not prop the door 5) Unhook the door. Fig. 30: Unhooking the door 11.2.6 Converting door to construction type BA2 Conversion from construction type BA1 (self-closing door) to construction type BA2 (non-self-closing door).
  • Page 66: Converting The Combustion Air Collar

    11 | Installation Operating manual Fireplac inserts slied flat + II 11.2.7 Converting the combustion air collar The combustion air is fed through a collar. The combustion air setting is carried out by the operator. The combustion air collar can be converted for the following fireplace inserts: 80x64 S / 80x64 SII / 97x45 S / 97x74 S / 120x45 S The combustion air collar can be mounted on the left- or right-hand side of the fireplace insert as desired.
  • Page 67: Mounting Large Top Storage Box

    Operating manual Fireplac inserts slied flat + II 11 | Installation 11.2.8 Mounting large top storage box Top storage box is available for all models except for 75x39 SII, 75x51 SII and 80x64 SII. 1) Loosen hexagon nuts, washers and clamping shoe (1). 2) Remove smoke collector.
  • Page 68: Mounting Top Storage Bricks

    11 | Installation Operating manual Fireplac inserts slied flat + II 4) Place exhaust manifold (5) on to the top storage box and fasten it to the bolt (4) with clamping shoe (3), washer (2) and hexagon nut (3) . 5) If necessary, bring the smoke collector into the correct position.
  • Page 69 Operating manual Fireplac inserts slied flat + II 11 | Installation 3) Attach bottom ring and fasten to the bolt with clamp- ing shoe, washer and nut. Fig. 39: Attaching the upper ring 4) If an exhaust sensor is used, it will be fastened with the M6x10 hexagon screw (2).
  • Page 70 11 | Installation Operating manual Fireplac inserts slied flat + II 6) The threaded rods (1) can be cut to the relevant length with a saw before or after mounting. ð Please ENSURE when cutting that the thread turn is not damaged.
  • Page 71: Installing The Hms

    11.2.10.1 HMS 65x51 S / 65x57 S / 75x39 S 1) Mount HMS holder (1) with screws. 2) Attach HMS brick (2) to the HMS mounting (1). 3) Repeat the steps for the other bricks. Fig. 45: Mounting 65x, 75x57 HMS...
  • Page 72 11 | Installation Operating manual Fireplac inserts slied flat + II 11.2.10.2 HMS 80x64 S / 97x S / 120x45 S 1) Undo marked screws. Fig. 46: Loosening the screws For the following step, for installation you will be using the screws which you have just loosened.
  • Page 73: Mounting The Designer Frame

    Operating manual Fireplac inserts slied flat + II 11 | Installation 7) Repeat this step for the remaining rear HMS bricks. Fig. 49: attaching the remaining HMS bricks 8) Attach side HMS bricks to the stove and on the lower tension support. 9) Attach side mountings and fasten with screws.
  • Page 74 11 | Installation Operating manual Fireplac inserts slied flat + II 2) Unbolt and open door. Fig. 52: Unbolting the door 3) Fasten design frame with the screws. ð For all S II fireplace inserts, the design frame is in- stalled on the rear side, in the same way as already described.
  • Page 75 Operating manual Fireplac inserts slied flat + II 11 | Installation 11.2.11.1 Flat solid design frame 1) Mount designer frame at the top. ð Only loosely connect the screws to the nuts. Fig. 54: Mounting the designer frame at the...
  • Page 76 11 | Installation Operating manual Fireplac inserts slied flat + II 2) Mount the designer frame at the bottom. ð Only loosely connect the screws to the nuts. Fig. 55: Mounting DF at the bottom...
  • Page 77 Operating manual Fireplac inserts slied flat + II 11 | Installation 3) Position the design frame sides on the left and right and use the screws to screw up at the top and bottom. Fig. 56: Mounting the DF at the side...
  • Page 78 11 | Installation Operating manual Fireplac inserts slied flat + II 4) Evenly align the design frame and tighten first the bot- tom screws, then the top ones. Fig. 57: Evenly aligning the frame The frame can only be loaded if the weight that is resting on the frame is supported via the extension arm on the wall Fig. 58: Loading the design frame...
  • Page 79: Mounting The Convection Cladding

    1) Install the mounting (1) on the left- and right-hand side in the bottom of the fireplace insert on the side. ð 80x and 97x do not have this mounting. 65x, 75x S 75x39 SII 75x51 SII Fig. 59: Installing the mounting...
  • Page 80 11 | Installation Operating manual Fireplac inserts slied flat + II 2) Attach right-hand side panel (1) to the mounting (2) and fasten with the screws. 3) Repeat this step for the side panel on the left-hand side. 4) For models without this mounting (2), fasten the side parts to the fireplace insert with the screws.
  • Page 81: Assembling Insertcontrol

    There are matching installation kits for the various fireplace inserts. The applicable fireplace inserts and the item num- bers of the installation kits are: 45x, 55x, 65x 75x – 363000 75X II - 363011 45x round – no InsertControl 45x II – no InsertControl Fig. 64: Installation kit 363000...
  • Page 82 11 | Installation Operating manual Fireplac inserts slied flat + II 3) Two holes must be drilled in the flue pipe for the tem- perature sensor. The position of the holes around the diameter of the flue pipe can be freely selected (see flue pipe drilling diagram).
  • Page 83 On some fireplace inserts the assembly situation can be se- lected on either the left- or right-hand side. Here you can see the assembly situations: 65x, 75x, (1) – left-hand assembly 65x, 75x, (2) – right-hand assembly 75x S II (3) – left-hand assembly 75x S II (4) –...
  • Page 84 11 | Installation Operating manual Fireplac inserts slied flat + II 6) Remove centre stone tension support (1). 7) Remove the two M6x12 hexagon head screws (2). 8) Remove primary air cover (3). ð Now InsertControl can be installed. Fig. 69: Removing the parts In the following illustration the 363000 installation kit has been installed in the left-hand version.
  • Page 85 Operating manual Fireplac inserts slied flat + II 11 | Installation 12) Thread the Bowden cable (1) through the Ø16 hole in the fireplace insert. Fig. 72: Threading the Bowden cable 12 mm 13) Connect the Bowden cable to the installation kit. 27 mm ð...
  • Page 86 11 | Installation Operating manual Fireplac inserts slied flat + II • Wait about 10 minutes after plugging in the power supply and check in that time that the air regu- lator disc has completely closed and opened • After the 10 minutes has finished the air regulator disc must be either completely opened or closed (depending on the program set) After a successful function test the fireplace insert can be completely reassembled.
  • Page 87 Operating manual Fireplac inserts slied flat + II 11 | Installation Program overview Selection wheel Mode Function Position 0 Shutter opening, always 60% Position 1 Normal sliding opening Position 2 sliding opening Position 3 Normal sliding closing Position 4 sliding closing Selecting the program 1) Remove power supply from the socket.
  • Page 88: Settings

    12 | Settings Operating manual Fireplac inserts slied flat + II Settings 12.1 Adjusting the door 97x45 S 1) Unlock door lift. Fig. 78: Locking the door lift 2) Open door. Fig. 79: Opening the door...
  • Page 89: Adjusting The Smoke Collector

    Operating manual Fireplac inserts slied flat + II 12 | Settings 3) The door can be adjusted at the marked places. 4) Lightly undo the screws and align the door. Fig. 80: Adjusting the door at top and bot- Fig. 81: Adjusting the door at the top Fig. 82: Adjusting the door at the bottom 12.2 Adjusting the smoke collector 1) Loosen screws (1).
  • Page 90 12 | Settings Operating manual Fireplac inserts slied flat + II 4) Loosen screws (3). 5) Turn the smoke collector collar (4) in order to bring it into the desired position. ð This allows any desired angle to be achieved by turning the exhaust collar (4).
  • Page 91: Commissioning

    Operating manual Fireplac inserts slied flat + II 13 | Commissioning Commissioning 13.1 Initial Commissioning ü The initial commissioning of your fireplace should take place 4 weeks at the earliest after comple- tion of the cladding, so that all cladding parts are able to dry out completely. 1) Remove all enclosed documents and appliance parts from the fireplace.
  • Page 92: Operation

    14 | Operation Operating manual Fireplac inserts slied flat + II Operation 14.1 Controls The appliance series is characterised by being extremely simple to use. Operation Convection outlet Door lock Convection inlet Combustion air controller Fig. 85: Operating functions on the appli- ance Door lock Opening the door:...
  • Page 93: Fuel

    Operating manual Fireplac inserts slied flat + II 14 | Operation 14.3 Fuel NOTICE To avoid damage you must NEVER operate your fireplace insert a greater quantity of fuel than that specified in this manual! Approved fuel Dry, properly stored, unrefined log (preferably hard wood) is permitted as fuel for our hybrid stoves Round wood must be split at least once so that it lights better.
  • Page 94: Heating

    14 | Operation Operating manual Fireplac inserts slied flat + II 3) Lay 2-3 pieces of log (1) (beech, oak, birch) across the bottom of the firebox. 4) Finely split softwood above it (2). 5) Place a firelighter (3) in the middle and light it. ð...
  • Page 95: Heating In The Transition Period

    Operating manual Fireplac inserts slied flat + II 14 | Operation Putting more wood on: 1) Fully open air control lever. ð This prevents any eddies that would allow flue gases to escape. If there is one, fully open the throttle valve.
  • Page 96: Operation

    Operating manual Fireplac inserts slied flat + II 14.9 Operation We would particularly like to point out at this point that Austroflamm fireplace inserts must only be op- erated with doors closed. The best efficiency and thus optimal fuel efficiency is achieved in closed op- eration.
  • Page 97: Cleaning

    2) Before cleaning the glass, the fireplace seat and floor covering must be covered. 3) Spray window with glass cleaner and leave it for a moment to take effect. ð We recommend cleaning the glass with our Austroflamm glass cleaner or a commercially available window cleaner.
  • Page 98: Cleaning The Door Window

    15.4 Cleaning the door window Spray window with glass cleaner and leave it for a moment to take effect. • We recommend cleaning the glass with our Austroflamm glass cleaner or a commercially available window cleaner. • Prevent door- or window seals from coming into contact with water or cleaner, since these will oth- erwise harden and in doing so lose their function.
  • Page 99: Help

    Operating manual Fireplac inserts slied flat + II 16 | Help Help Problem Cause Solution The glass window is sooty Insufficient draft from time to time (depending on use) the window must be cleaned with glass cleaner Clarification with chimney sweeper (poss.
  • Page 100: Firebox Lining

    16 | Help Operating manual Fireplac inserts slied flat + II Problem Cause Solution Ceramic windows become sooty Unsuitable wood used Use dry unrefined wood. See inform- very quickly ation about this in the Fuel section Operating temperature not reached Bring fireplace insert to the operat- ing temperature Sooting up of the window after 8- 10 hours of fires is normal...
  • Page 101 Operating manual Fireplac inserts slied flat + II 16 | Help • Is the firebox door correctly closed? • Is the chimney draft too high? ... the ceramic panes become sooty very quickly? • A gradual accumulation of soot by the windows after 8 to 10 hours of fires is normal. •...
  • Page 102: Spare Parts

    17 | Spare parts Operating manual Fireplac inserts slied flat + II Spare parts To order spare parts, please contact your Austroflamm dealer.
  • Page 103: Dismantling

    Operating manual Fireplac inserts slied flat + II 18 | Dismantling Dismantling 18.1 Execution 18.1.1 Removing revision and weight cartridge 1) Remove side Keramott bricks. 2) Remove screws from the revision. 3) Open inspection cover (press downwards). Fig. 90: Removing revision and weight cart- ridge 4) Remove weight cassette.
  • Page 104: Disposal

    (Keramott), ceramic, sensors and baffle plates and dispose of them in the household waste. NOTICE For correct uninstallation and dismantling of the fireplace insert, contact your Austroflamm specialist dealer. Electric and electronic components Remove the electric and electronic components from the appliance by dismounting them.
  • Page 105 Operating manual Fireplac inserts slied flat + II 19 | Disposal Handles and decorative elements made of metal If present, disassemble or remove handles and decorative elements made of metal and dispose of as metal scrap. Local disposal options must be observed.
  • Page 106: Guarantee And Warranty

    For the replaceability of the warranty case the start-up log must be received by Austroflamm within one month at the latest of the initial commis- sioning. In order to make a claim on the warranty, repairs to your fireplace insert must only be car- ried out by a service engineer authorized by Austroflamm.
  • Page 107: Data Processing

    If you consent to the appropriate handling of your personal data for the following purposes, please tick this box. o I hereby agree that Austroflamm GmbH and AUSTROFLAMM Service GmbH & Co KG may send me service reminders and offers on other products from Austroflamm GmbH for the purposes of advert- ising via E-Mail/ SMS/ telephone.
  • Page 108: Start Up Log

    22 | Start up log Operating manual Fireplac inserts slied flat + II Start up log Operator / Customer Dealer / Engineer Name Company Street Street Town and postal code Town and postal code Telephone Telephone Email Email Fireplace insert Working Comments Model...
  • Page 109: Service Report

    Operating manual Fireplac inserts slied flat + II 23 | Service Report Service Report Date Technicians Notes Work carried out, replacement parts installed...
  • Page 110 23 | Service Report Operating manual Fireplac inserts slied flat + II Date Technicians Notes Work carried out, replacement parts installed...
  • Page 111 Notizen / notes / appunti / remarques...
  • Page 112 Vollständigkeit / completeness / completo / complet Geprüft von / checked by / controlled da / contrôlé par ____________________________________________________ Datum / date / data / date ____________________________________________________ AUSTROFLAMM GMBH Austroflamm-Platz 1 A- 4631 Krenglbach Tel: +43 (0) 7249 / 46 443 www.austroflamm.com info@austroflamm.com...

This manual is also suitable for:

75x75x39 sii75x51 sii80x6480x64 sii97x ... Show all

Table of Contents