  • Page 1 Operating manual Pallas Back www.austroflamm.com...
  • Page 2 Tel: +43 (0) 7249 / 46 443 www.austroflamm.com info@austroflamm.com Edited by: Olivera Stojanovic Illustrations: Konstruktion Text: Technical department (Austroflamm) Copyright All Rights reserved. The contents of these instructions may be reproduced or distributed only with the consent of the publisher! Printing, spelling and typographical errors reserved.
  • Page 3: Table Of Contents

    Operating manual Pallas Back Contents Contents General information ............................Copyright.............................. Purpose of the manual ............................Storing the manual ..........................Structure of the manual........................Representations used.......................... Version control............................. Abbreviations ............................Safety ..................................Importance of the safety instructions ....................General safety instructions .........................
  • Page 4 Contents Operating manual Pallas Back 9.2.4 Installing the HMS..........................26 9.2.5 Mounting the Keramott........................28 9.2.6 Rearranging the flue pipe connection ....................28 9.2.7 Installing the log drawer ........................31 10 Settings................................. 32 10.1 Adjusting the door lock ........................32 11 Commissioning..............................
  • Page 5: General Information

    Operating manual Pallas Back 1 | General information General information You have decided in favor of an Austroflamm stove. Congratulations on your decision and thank you for your trust. Correct operation and care are essential for trouble-free operation and long service life.
  • Page 6: Purpose Of The Manual

    2 | Purpose of the manual Operating manual Pallas Back Purpose of the manual This manual is a component part of the stove and is intended to contribute to the stove being safely in- stalled and maintained. Please read this manual before using the stove for the first time.
  • Page 7: Abbreviations

    Operating manual Pallas Back 2 | Purpose of the manual Abbreviations Abbreviation Meaning Heat Memory System Stoves...
  • Page 8: Safety

    3 | Safety Operating manual Pallas Back Safety In this manual we give you numerous safety instructions for the safe operation of your stove. These in- structions are characterized differently as follows, depending on their importance: Importance of the safety instructions NOTICE Particular behaviour and/or activities that are required for safe working.
  • Page 9: Special Types Of Danger And Personal Protective Equipment

    Operating manual Pallas Back 3 | Safety • Please alert children to these dangers, and keep them away from the stove when it is operating. DANGER Danger of overheating To prevent damage you must NEVER operate your stove with a greater quantity of fuel than the...
  • Page 10: Product Overview

    Operating manual Pallas Back Product overview Intended use The Austroflamm stove described in this manual is manufactured and tested with a type A1 self-closing and locking door under EN test EN 13240. NOTICE Operation is only permissible with closed/bolted door.
  • Page 11: Energy Label

    Operating manual Pallas Back 4 | Product overview 1) Open (+) and closed (-) (primary/secondary air control- ler) Fig. 2: Safety distances (a, b, c) / air control- Energy label -80% Austrof amm Pallas Back -60% -40% -20% ENERGIA · ЕНЕРГИЯ · ΕΝΕΡΓΕΙΑ · ENERGIJA · ENERGY · ENERGIE · ENERGI 2015/1186 Fig. 3: Energy label...
  • Page 12: Positioning Of The Nameplates

    4 | Product overview Operating manual Pallas Back Positioning of the nameplates Here we show where you can find the nameplate. You can find a copy of the nameplate of your stove on the back of this manual. The type label is located on the rear of the stove.
  • Page 13: Technical Data

    Operating manual Pallas Back 5 | Technical data Technical data As a type 1 stove, a connection to a chimney already occupied with other solid-fuel stoves and ovens is possible provided that the chimney rating under DIN 4705 – part 3, does not contravene this.
  • Page 14 5 | Technical data Operating manual Pallas Back Lignite briquettes Peat briquettes Briquettes made from a mixture of fossil fuels Other fossil fuels Briquettes made from a mixture of biomass and fossil fuels Other mixture of biomass and fossil fuels (*) PM = dust, OGC = organic gaseous connections, CO = carbon monoxide, NOx = nitrogen oxide (**) Only required when using correction factors F(2) or F(3).
  • Page 15: General Specifications

    Operating manual Pallas Back 5 | Technical data Specification mg/m³ for heated filter method (in compliance with Annexe III, number 4, letter a, sec- tion i, point 1) or g/kg for measurement in dilution tunnel (in compliance with Annexe III, number 4, let- ter a, section i, point 2 and 3.)
  • Page 16: Transport, Handling And Storage

    6 | Transport, handling and storage Operating manual Pallas Back Transport, handling and storage Transportation Immediately checked the goods delivered for complete- ness and damage in transit. Before installing the stove, check that all movable parts are working. Any defects before the installation of the stove must be reported.
  • Page 17: Requirements At The Installation Location

    When connecting the flue pipes to the chimney, national and/or local safety regulations must be com- plied with. Your Austroflamm stove is fitted at the factory with a flue pipe outlet at the top (diameter 150 mm). The connection can, as described in these instructions, be rearranged to the bottom. When connecting with other pipe diameters the approval of your responsible chimney sweep is required.
  • Page 18: Floor Load-Bearing Capacity

    7 | Requirements at the installation location Operating manual Pallas Back Floor load-bearing capacity Before installing, verify whether the load-bearing capacity of the substructure can withstand the weight of your Austroflamm stove. Floor condition In the radiation area of the pane (in front of the stove), the floor must not be combustible.
  • Page 19: Fuel Material/-Quantity

    Operating manual Pallas Back 8 | Fuel material/-quantity Fuel material/-quantity Fuel Wood Many of our native types of wood can, after being appropriately dried, be burnt CO2-neutral in heat- producing appliances. Wood stands out because it grows again, can be sustainably harvested, re- quires little or no extra external energy to be invested in the fuel, and has a short journey from the pro- ducer to the consumer, which provides an optimal climate balance.
  • Page 20 8 | Fuel material/-quantity Operating manual Pallas Back Please observe at all times the maximum specified amount to be laid, even when putting on more wood! Otherwise your fire will not provide the desired efficiency - but above all considerable damage may be caused to your appliance, to gaskets and material and to the flue gas duct.
  • Page 21: Fuel Quantity

    Maximum amount of fuel to be deposited: 2.7 kg wood or briquettes. NOTICE Overheating Too great a quantity of fuel can lead to overheating and damage to your Austroflamm stove NOTICE To avoid damage you must NEVER operate your Stove a greater quantity of fuel than that specified in...
  • Page 22: Installation

    9 | Installation Operating manual Pallas Back Installation Installation must only be carried out by an authorized specialist company. Before installing the stove, check that all movable parts are working. Any defects must be reported be- fore the installation. In the following sections we will give you information on •...
  • Page 23 Operating manual Pallas Back 9 | Installation 2) Lift the rear panel upwards and remove it. Fig. 8: Lifting the rear panel upwards and re- moving it 3) Open the door of the baking compartment. 4) Remove the prefitted screw from the inside of the bak- ing compartment (left and right) with an Allen key (SW 2.5).
  • Page 24: Mounting The Ceramic Side Cladding

    9 | Installation Operating manual Pallas Back 9.2.2 Mounting the ceramic side cladding 1) If the steel cladding is mounted, it must first be dis- mounted. ð Proceed as described in the section Removing the steel side cladding [}on page 47].
  • Page 25: Mounting The Soapstone Side Cladding

    Operating manual Pallas Back 9 | Installation 4) Hang the upper part of the ceramic side cladding on the screws from top to bottom. 5) Repeat the last three stages on the other side of the stove to mount the ceramic side cladding.
  • Page 26: Installing The Hms

    9 | Installation Operating manual Pallas Back 3) Hang the soapstone cladding (1) on the screws from top to bottom, while at the same time pressing down towards the stove and attaching the top cover (2). 4) Repeat the stages on the other side of the stove to mount the soapstone side cladding.
  • Page 27 Operating manual Pallas Back 9 | Installation 3) HMS brick can now be mounted on the holders. Fig. 17: Mounting HMS brick 4) To mount the HMS brick on the left hand side of the stove, repeat the last two stages.
  • Page 28: Mounting The Keramott

    9 | Installation Operating manual Pallas Back 9.2.5 Mounting the Keramott Numbering = installation sequence Fig. 20: Keramott 9.2.6 Rearranging the flue pipe connection 1) First remove the lid. 2) Then press the rear panel upwards and remove it. Fig. 21: Removing the cover and rear panel 3) Use a saw to remove the perforated cut-out on the rear panel.
  • Page 29 Operating manual Pallas Back 9 | Installation 4) Detach the bracket and the seal from the lid. Fig. 23: Detaching the bracket and seal from the lid 5) Remove cover at the rear. Fig. 24: Removing the cover 6) Fit the bracket in the place of the cover at the rear.
  • Page 30 9 | Installation Operating manual Pallas Back 7) Hang the rear panel from top to bottom. Fig. 26: Hanging the rear panel 8) Mount the cover from the rear on to the lid. Fig. 27: Mounting the cover on the lid 9) Attach lid.
  • Page 31: Installing The Log Drawer

    Operating manual Pallas Back 9 | Installation 9.2.7 Installing the log drawer 1) Glue the two bump stops (1) from inside to the rear wall. ð Only fix the two stop plates (2) with two screws each if necessary. 2) The log drawer can now be slid into the stove.
  • Page 32: Settings

    10 | Settings Operating manual Pallas Back Settings 10.1 Adjusting the door lock 1) Open door. 2) The door lock can be adjusted using the marked screws. Fig. 30: Adjusting the door lock...
  • Page 33: Commissioning

    Operating manual Pallas Back 11 | Commissioning Commissioning 11.1 Initial Commissioning NOTICE During the initial commissioning and in the following 2-3 combustion cycles, only approx. 2/3 of the maximum fuel quantity is to be used. NOTICE To avoid damage you must NEVER operate your Stove a greater quantity of fuel than that specified in this manual! During the first 3-4 combustion cycles at nominal heat output, odors may develop.
  • Page 34: Operation

    12 | Operation Operating manual Pallas Back Operation 12.1 Before heating up The stove can only function properly if there is sufficient combustion air coming to the room of installa- tion (the appliance), specially if several firing installations are being operated at the same time. Ensure sufficient air supply before heating up.
  • Page 35: Heating In The Transition Period

    Operating manual Pallas Back 12 | Operation 9) As soon as the pieces of firewood are burning well all around (light, high flames), you can control the air supply with the controller. ð Control at maximum setting right = maximum heat output ð...
  • Page 36: Maintenance

    13 | Maintenance Operating manual Pallas Back Maintenance 13.1 Changing the seal on the door 1) Remove old seal from the door. 2) Glue in new seal with a suitable adhesive (e.g. silicon B310). ð Repeat these steps for the baking compartment door as well Fig. 34: Changing the seal...
  • Page 37: Cleaning

    Operating manual Pallas Back 14 | Cleaning Cleaning 14.1 Cleaning the stove, flue gas ducts and flue pipe The stove, the flue gas ducts and flues should be annually - possible even more often, e.g. • after the chimney has been cleaned •...
  • Page 38 14 | Cleaning Operating manual Pallas Back 3) Take the supplied cover and use it to cover the ash box. 4) Turn the handle of the cover clockwise until the handle engages. Fig. 36: Putting the cover on the ash box Fig. 37: Closing the cover...
  • Page 39: Cleaning The Door Window

    14.4 Cleaning the door window Spray window with glass cleaner and leave it for a moment to take effect. • We recommend cleaning the glass with our Austroflamm glass cleaner or a commercially available window cleaner. • Prevent door- or window seals from coming into contact with water or cleaner, since these will oth- erwise harden and in doing so lose their function.
  • Page 40: Help

    15 | Help Operating manual Pallas Back Help Problem Cause Solution The glass window is sooty Insufficient draft from time to time (depending on use) the window must be cleaned with glass cleaner Clarification with chimney sweeper (poss extend chimney/measure...
  • Page 41: Firebox Lining

    Operating manual Pallas Back 15 | Help Problem Cause Solution Operating temperature not reached Bring stove to the operating temper- ature Sooting up of the window after 8- 10 hours of fires is normal Chimney draft too low Contact chimney sweep 15.1 Firebox lining...
  • Page 42: Accessories

    Baking compartment The Pallas Back design is distinguished from the Pallas design by its fully functional baking compart- ment. This baking compartment is heated from 4 sides (left, right, back and bottom).
  • Page 43: Spare Parts

    Operating manual Pallas Back 17 | Spare parts Spare parts Accessories Item no. Quantity Item Item no. Ash pan set 350035 HMS complete 051011 Log drawer, complete 051012-29 Ceramic cladding, complete 051016-XX Pallas Back, complete 051014 Soapstone case, complete 051018...
  • Page 44 17 | Spare parts Operating manual Pallas Back Keramott Item no. Quantity Item Item no. Keramott floor plate, middle 712760 Keramott back left 712761-A Keramott back right 712761-B Keramott left 712762 Keramott right 712763 Keramott floor left 712766 Keramott floor right...
  • Page 45 Operating manual Pallas Back 17 | Spare parts Item no. Quantity Item Item no. HMS holder 712784-95 HMS sheet 45998-94 HMS rear 770074 HMS side 770075...
  • Page 46 17 | Spare parts Operating manual Pallas Back Log drawer Item no. Quantity Item Item no. Blind rivet nut M8-UT/FEF 3 712712-93 Gasket 8x2x120 710096 Mushroom head blind rivet 4.0x7.6 718358-91 Head nut M5 pattern 718215-91 Large diameter washer M5...
  • Page 47: Dismantling

    Operating manual Pallas Back 18 | Dismantling Dismantling For correct uninstallation and dismantling of the stove, contact your Austroflamm specialist dealer. 18.1 Removing the steel cladding 1) Detach cover (if mounted). Fig. 39: Detaching the cover 2) Lift the rear panel upwards and remove it.
  • Page 48 18 | Dismantling Operating manual Pallas Back 3) Use a cross-point screwdriver to unscrew the screws at the rear from the steel side cladding. Fig. 41: Unscrewing the screws at the rear 4) The front four screws must be removed. ð The top two screws are located in the interior of the stove.
  • Page 49: Disposal

    NOTICE For correct uninstallation and dismantling of the stove, contact your Austroflamm specialist dealer. Electric and electronic components Remove the electric and electronic components from the appliance by dismounting them. These com- ponents must not be disposed of via non-recyclable waste.
  • Page 50 19 | Disposal Operating manual Pallas Back Handles and decorative elements made of metal If present, disassemble or remove handles and decorative elements made of metal and dispose of as metal scrap. Local disposal options must be observed.
  • Page 51: Guarantee / Warranty

    For the replaceability of the warranty case the start-up log must be received by Austroflamm within one month at the latest of the initial commissioning. In or- der to make a claim on the warranty, repairs to your stove must only be carried out by a service en- gineer authorized by Austroflamm.
  • Page 52: Data Processing

    If you consent to the appropriate handling of your personal data for the following purposes, please tick this box. o I hereby agree that Austroflamm GmbH and AUSTROFLAMM Service GmbH & Co KG may send me service reminders and offers on other products from Austroflamm GmbH for the purposes of advert- ising via E-Mail/ SMS/ telephone.
  • Page 53: Start Up Log

    Operating manual Pallas Back 22 | Start up log Start up log Operator / Customer Dealer / Engineer Name Company Street Street Town and postal code Town and postal code Telephone Telephone Email Email Stove Working Comments Model Serial number...
  • Page 54: Service Report

    23 | Service Report Operating manual Pallas Back Service Report Date Technicians Notes Work carried out, replacement parts installed...
  • Page 55 Operating manual Pallas Back 23 | Service Report Date Technicians Notes Work carried out, replacement parts installed...
  • Page 56 Notizen / notes / appunti / remarques...
  • Page 57 Notizen / notes / appunti / remarques...
  • Page 58 Vollständigkeit / completeness / completo / complet Geprüft von / checked by / controlled da / contrôlé par ____________________________________________________ Datum / date / data / date ____________________________________________________ AUSTROFLAMM GMBH Austroflamm-Platz 1 A- 4631 Krenglbach Tel: +43 (0) 7249 / 46 443 www.austroflamm.com info@austroflamm.com...