Bose PowerSpace+ Configuration Utility User Guide
600 Ω Telephone Paging Connection
The default telephone paging activation method is VOX (voice activated). The telephone paging stimulus
can be changed to PTT (push-to-talk) in the web-served UI. Connect the Push-to-Talk contact to the PTT
pin of input 4. Use the included green 4-pin Euroblock to make this connection.

Mute with Standard Contact Closure

The P4300+ and P4150+ are designed to mute all outputs when the Mute
contacts are either shorted together or opened, depending on how the amp-
lifier is configured.
The default state is Normally Open (NO), where a short across the mute con-
nector will mute all outputs. Using the integrated web server, the mute polar-
ity can be inverted to Normally Closed (NC), where an open across the
mute connector will mute all outputs.
Use the included black 2-pin Euroblock to make this connection.
Note: All Limit LED indicators will blink red when the amplifier is muted from software or from the rear
panel Mute connector.

Connecting to a Network

The P4300+ and P4150+ include an RJ-45 Ethernet port on the rear panel for network con-
nection.
Use a foiled or unshielded twisted-pair (F/UTP) Cat 5e cable (not included) to connect this port
on each amplifier to your network or computer. Make this connection directly to the
amplifier or through a switched Ethernet network.
Note: All PowerSpace+ amplifiers are set to DHCP, which you can change by using the web-served UI.
- 35 -