Avalue Technology OFP-21W38 Quick Reference Manual page 11

21" open frame panel pc
Table of Contents

Advertisement

Mechanical Shock
Test
Drop Test
Operating
Temperature
Operating
Humidity
Storage
Temperature
Power
Consumption
Note:
Specifications are subject to change without notice.
1 Test PSD : 0.026G²/Hz , 2.16 Grms
2 Test frequency : 5~500 Hz
3 Test axis : X,Y and Z axis
4 Test time : 30 minutes per each axis
5 IEC 60068-2-64 Test Fh
1 Wave from : Half Sine wave
2 Acceleration Rate : 10g for operation mode
3 Duration Time : 11ms
4 No. of shock : Z axis 300 times
5 Test Axis : Z axis
6 operation mode
7 Reference IEC 60068-2-27 testing procedures
Test Eb : Shock Test
Package drop test
Reference ISTA 2A, Method : IEC-60068-2-32 Test:Ed
Test Ea : Drop Test
1 Test phase : One corner, three edges, six faces
2 Test high : 96.5cm
3 Package weight : 5.0 kg
4 Test drawing
0°C ~ 45°C (32°F ~ 113°F)
*Air flow=0.5 m/s
40°C @ 95% Relative Humidity, Non-condensing
-20°C ~ 60°C (-4°F ~ 140°F)
Max. load 65.36W with intel core i7-1195G7E/4GB/64GB(M.2
SSD)/64BG(2.5" SSD), 24V DC-in