Etnyre BLACK-TOPPER Manual

Etnyre BLACK-TOPPER Manual

Standard spraybar with touch screen controls

Advertisement

Quick Links

A-128-23
Serial Numbers S9000 and up
BLACK-TOPPER
®
Flow Charts and Control Positions
Standard Spraybar
with
Touch Screen Controls
E. D. ETNYRE & CO.
1333 S. Daysville Road, Oregon, Illinois 61061
PARTS/SERVICE: 888-586-1899 Fax: Sales 815-732-7400
email: CustomerService@etnyre.com www.etnyre.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BLACK-TOPPER and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Etnyre BLACK-TOPPER

  • Page 1 A-128-23 Serial Numbers S9000 and up BLACK-TOPPER ® Flow Charts and Control Positions Standard Spraybar with Touch Screen Controls E. D. ETNYRE & CO. 1333 S. Daysville Road, Oregon, Illinois 61061 PARTS/SERVICE: 888-586-1899 Fax: Sales 815-732-7400 email: CustomerService@etnyre.com www.etnyre.com...
  • Page 2: Etnyre Spray Bar Nozzles

    Etnyre Spray Bar Nozzles Application Application US Flow...
  • Page 3: Table Of Contents

    Control Panels .............5 This pamphlet is provided as a tool to aid personnel in the Load through Manhole..........6 operation of the Etnyre Blacktopper Distributor, as with any type Load through Load Line..........7 of construction equipment, there are certain hazards associated with improper or careless operation.
  • Page 4: Bar Suck Back Override

    Bar Suck Back Override The Suck Back Override feature is now standard on every machine, and is designed for quick in-cab switching from BAR CIRC to SUCK BACK mode while spraying. When the SUCK BACK OVERRIDE button is activated, all valves open in SPRAY mode will close, and the pump will begin sucking back material in the spray bar at 200 GPM.
  • Page 5: Control Panels

    Control Panels 1. MASTER SPRAY Switch • Spray Icon • AUTO / MANUAL Pump Control Icon Turning this switch to ON opens all activated • Asphalt Pump Speed (GPM or LPM) spray valves when BAR CIRCULATE or SUCK BACK is selected. 6.
  • Page 6: Load Through Manhole

    Load through Manhole WARNING To prevent possible injury, always open the manhole cover slowly. Pressure build up in the tank may cause the cover to burst open. M-103-22 M-103-22 Distributor Distributor (P. 46) (P. 46)
  • Page 7: Load Through Load Line

    Load through Load Line Cab Panel Rear Panel The instructions represented here are a guide and not designed to be comprehensive. Refer • POWER Switch ON • POWER Switch ON • POWER Switch (E Stop) ON • POWER Switch (E Stop) ON to M-103-22 Distributor Operation Manual •...
  • Page 8: Circulate In Tank

    Circulate In Tank Rear Panel The instructions represented here Cab Panel are a guide and not designed to be • POWER Switch (E Stop) ON • POWER Switch (E Stop) ON • POWER Switch ON • POWER Switch ON comprehensive. Refer to M-103-22 •...
  • Page 9: Circulate In Bar

    Circulate In Bar The instructions represented here are a guide and not designed to be comprehensive. Refer to M-103-22 Distributor Cab Panel Operation Manual (P, 52) • MASTER SPRAY Switch OFF • MASTER SPRAY Switch OFF for complete instructions. Rear Panel •...
  • Page 10: Spray

    Spray NOTE: Unit should already be operating in Bar Circulate and circulating oil to be ready to spray 4 WayValve BAR CIRC (Keyway in 6 o’clock position - with Spray switch ON) The instructions represented here are a guide and not designed Cab Panel to be comprehensive.
  • Page 11: Suckback Spraybar

    Suckback Spraybar SUCK BACK Bleeder Valve is last flip lever The instructions valve on wings. represented here are a guide and not designed to be comprehensive. Cab Panel Refer to M-103-22 Distributor • POWER Switch ON • POWER Switch ON Operation Manual •...
  • Page 12: Handspray

    Handspray For safety reasons, it is recommended to use Auto function while handspraying. The instructions represented here are a guide and not designed to be Rear Panel comprehensive. Refer to M-103-22 Cab Panel Distributor Operation Manual (P.60) • POWER switch (E Stop) ON •...
  • Page 13: Suckback Handspray

    Suckback Handspray The instructions represented here are a guide and not designed to be Rear Panel comprehensive. Refer to M-103-22 Cab Panel • POWER switch (E Stop) ON Distributor Operation Manual (P. 62) • POWER switch ON • PUMP CONTROL Set to AUTO for complete instructions.
  • Page 14: Flushing Bar - Auto

    Flushing (AUTO) FLUSH Rear Panel The instructions represented here are a guide • POWER switch (E Stop) ON and not designed to be comprehensive. Refer to Cab Panel • Operation Mode Set to FLUSH M-103-17 Centennial Operation Manual (P. 64) •...
  • Page 15: Flushing Bar - Manual

    Unload with External Pump (Gravity) 4 WayValve TANK CIRC (Keyway in 12 o’clock position - with Spray Connect Load Line to the Storage Tank switch ON) pump or distributor you wish to transfer to. Do not remove Load Line cap if front or rear tank valve is open.
  • Page 16: Unload (With External Pump)

    Unload with Distributor Pump The instructions represented here Rear Panel are a guide and not designed to be • POWER switch (E Stop) ON comprehensive. Refer to M-103-22 • Operation Mode Set to UNLOAD Distributor Operation Manual (P. 68) • PUMP CONTROL Set to MANUAL for complete instructions.
  • Page 17: Unload (With Distributor Pump)

    Transfer Pump Rear Panel • POWER switch (E Stop) ON The instructions represented here • Operation Mode Set to TRANSFER are a guide and not designed to be • PUMP CONTROL Set to MANUAL comprehensive. Refer to M-103-17 • Tap START. Increase PUMP SPEED Slider Cab Panel Centennial Operation Manual (P.