6.3 Connection of outlet hose
(concentrate)
The outlet water from the plant (concentrate) is
led out through the connection in the middle of
the left side of the plant labeled "concentrate".
The water is led to floor drain.
Important! The outlet pipe may not be inserted
into the water in the floor drain as there is
then a risk that this water gets sucked back
into the plant during standstills.
Important! There must never be a resistance in
the outlet pipe, as this will damage the plant
membrane(s).

6.4 Connection of overflow hose

At the left side of the plant the overflow nozzle
shall connected to a ½" plastic hose which
shall be led to the floor drain. this overflow is
a safety overflow in case of errors occurring
on the plant level sensor and the reservoir tank
consequently gets overfilled.
6.5 Connection of soft-water control
valve
Install the test valve on the left side of the
plant. The test valve is to be fitted on the
connection closest to the front, see encl. 14.2
fig. 1 (the valve is in the salt tank).
7

Electric connections

Note! The electric connections must be done in
compliance with local regulations.
The electric connection to the BWT PERMAQ
Compact 950 plant must be as follows:
Voltage: 3 x 400 Volt + 0 + Earth fuse: 16
Amp – 3.5 kW
8
All internal connections in the plant like e.g.
pump control and level control have been
preassembled in our factory. They only have
to be connected to the main current in the
terminal box.
See also wiring diagram (enclosure).
8

Commissioning of the plant

Check before start-up that all water and
electric connections are done as described in
previous chapters and in compliance with
local regulations.

8.1 Start-up of softening plant

1. Check that the number (see encl.
diagram page 6) of the standard-
mounted regeneration meter disk fits
the actual hardness on site. If not, the
meter disk (water meter) must be
exchanged, see illustrations 2.1, 2.2
and 2.3 on page 5. You can order the
correct meter disk from BWT HOH or
your supplier.
2. The brine valve has been pre-adjusted
in our factory, but it should always be
checked that the float (A-figure 1) is
halfway up the shaft as a minimum
when looking from the top of the float.
The water must be above the grid plate
in order to be in contact with the slat.
This also applies to the yellow plastic
ring (B-figur 1) under the float; it must
be pressed home.
3. The valves on the in- and outlet side
and the bypass valve (if fitted) must be
closed.
4. Open the valves at the intake side a
little so that the filter slowly fills
EN