BWT bestaqua 60 Installation And Operating Manual

BWT bestaqua 60 Installation And Operating Manual

Reverse osmosis plant
Hide thumbs Also See for bestaqua 60:

Advertisement

Quick Links

Installation and Operating manual
EN
BW T bes taqua 60 - 62
Reverse Osmosis Plant

Advertisement

Table of Contents
loading

Summary of Contents for BWT bestaqua 60

  • Page 1 Installation and Operating manual BW T bes taqua 60 - 62 Reverse Osmosis Plant...
  • Page 3: Table Of Contents

    Content 1 General information .............. 5 2 Explanation of words ............5 3 Function descriptions ............. 6 Permeate production ....................6 4 Positioning of the RO unit ............6 5 Water quality ................ 7 6 Water connections ..............7 Connection of feed water (inlet water) ................7 Connection of outlet hose ....................
  • Page 4 Overview of the Status- and Alarm LED ..............19 11.4 Troubleshooting ....................19 12 Technical specifications ............20 13 Appendix ................21 13.1 Preset standard values for BWT bestaqua 60, 61 and 62 ........21 13.2 Wiring diagram ....................22 13.3 PI-diagram ......................25 13.4 Arrangement drawing ...................
  • Page 5: General Information

    General information Your BWT bestaqua 60-62 is of a compact design with integrated reservoir tank in order This installation and operating manual (OPM) to take up as little space as possible. applies bestaqua 60-62 total With its compact and finished design, your desalination unit.
  • Page 6: Function Descriptions

    Level switch: Is a switch, which gives a water in the reservoir does not overflow when signal when the BWT bestaqua 60-62 unit the tank is full. must either be started or stopped, and it stops...
  • Page 7: Water Quality

    The best operating result is obtained by The feed water, which is to be treated in the connecting to minimum ¾” feed-water pipe. BWT bestaqua 60-62 unit, must be drinking That reduces the drop in pressure to the RO water quality with maximum 500 mg/l TDS.
  • Page 8: Connection Of Outlet Hose

    Note! The electrical connections must be made in compliance with local regulations. Install the supplied 12 mm plastic hose to outlet. The electrical connection to the BWT bestaqua 60-62 unit must be as follows: Note! It is important that the hose is pressed ...
  • Page 9: Function Buttons Og Display Elements

    Function buttons og display elements [ON/OFF] key switches the device from standby to ON/OFF when pressed continuously for 2 sec and performs the reset of the device in case of alarms and/or failures. [ON/OFF] key stop/pauses the RO unit when pressed shortly (Arrow up) key scrolls through the menu pages upward / right, increases the value of the parameter presently shown on the display.
  • Page 10: Menu: Settings / General

    8.1 Menu: Settings / GENERAL...
  • Page 11: Menu: Settings / Pressure

    8.2 Menu: Settings / Pressure 8.3 Menu: Settings / Conductivity...
  • Page 12: Menu: Settings / Wcf Setup

    8.4 Menu: Settings / WCF Setup 8.5 Menu: Settings / System delays...
  • Page 13: Menu: Installation (Password Protected)

    8.6 Menu: Installation (password protected)
  • Page 14: Menu: Maintenance

    8.7 Menu: MAINTENANCE 8.8 Menu: INFO...
  • Page 15: Start-Up Of The Ro Unit

    Start-up of the RO unit Note! Only for BWT bestaqua 60 LT: After 30 minutes’ rinse the RO unit will Read section below carefully before starting automatically start to produce permeate if up the RO unit. there is consumption. But the technician can use flowmeter from 451409006 “RO...
  • Page 16: Adjustment Of Recirculation Amount

     permeate capacity bestaqua 60-62 at a temp. of 10-25 °C. If the temp. is below 10 °C, the capacity will Outlet amount (l/h) be 3 % below normal capacity for every degree under 10 °C. If e.g. the feed-water temp. is 8 °C, for an...
  • Page 17: Start-Up Of Transportpump (Model Lt & Hq)

    10 Automatic functions the lock nut. NB! When the valves have been locked, the The BWT bestaqua 60-62 unit is equipped RO unit shall be started and stopped 4-5 times with a control box which has following built-in and then the flow shall be checked again; the control functions: valves are re-adjusted if necessary.
  • Page 18: Maintenance And Troubleshooting

    V-cup seal must be fitted at the same end of the membrane as the old one, i.e. if the V- The BWT bestaqua 60-62 unit is produced cup seal is at the top of the pressure vessel., and designed for a minimum of servicing and the V-cup seal of the new membrane must also maintenance.
  • Page 19: Overview Of The Status- And Alarm Led

    Please observe: If your reverse osmosis is not performing as it should, please run through the alarm messages below. In the case of a fault, repair work may only be carried out by an expert (call BWT SERVICE technician). When Alarm sound press on to see Alarm details.
  • Page 20: Technical Specifications

    12 Technical specifications BWT bestaqua units 60HQ 61HQ 62HQ 60LT 61LT 62LT Performance Nominal capacity, 10 °C * Nominal capacity, 15 °C * Permeate conductivity (max.) µS/cm < 20 < 20 Salt retention rate > 99 >99 40…80 40…75 Permeate output WCF ** (min…max.)
  • Page 21: Appendix

    13 Appendix 13.1 Preset standard values for BWT bestaqua 60, 61 and 62 Parameter: Interval and unit: Default values: DATE [Day /month / year] Actual date TIME [Timer : minutter] Actual time LANGUAGE EN, DK, DE, IT, FR CONDUCTIVITY LIMIT 0-190 µS...
  • Page 22: Wiring Diagram

    13.2 Wiring diagram...
  • Page 23 LS/ Level switch V06/ Servomotor QUIT01/ Inlet conductivity PT01/HP pump sensor PT02/TP pump sensor FT02/ Concentrate flowmeter QUIT02/ Permeat conductivity FT01/ Permeate flowmeter LCD console 10) Y02 / Flush solenoid valve 11) Y01/ Inlet solenoid valve...
  • Page 24 Input 1 External WCF switch Input 2 External stop TP pump Output 1 Reservoir is full/empty Output 2 Alarm HP pump TP pump capacitor TP pump...
  • Page 25: Pi-Diagram

    13.3 PI-diagram...
  • Page 26: Arrangement Drawing

    13.4 Arrangement drawing 13.4.1 Arrangement drawing: BWT bestaqua 62HQ...
  • Page 27: Arrangement Drawing: Bwt Bestaqua 62Hq + Bwt Aquaflex 38 (Optional)

    13.4.2 Arrangement drawing: BWT bestaqua 62HQ + BWT aquaflex 38 (Optional)
  • Page 28: Start-Up Control

    13.5 Start-up control...
  • Page 29: Operating Journal

    13.6 Operating journal Maintenance intervals should be performed once a week. Replacement frequency of wearing parts shown in chapter “14.8 Spare parts list BWT bestaqua 60-62”.
  • Page 30: Spare Parts Drawing

    13.7 Spare parts drawing 13.7.1 Spare part drawing: BWT bestaqua 62HQ...
  • Page 31: Spare Part Drawing: Bwt Bestaqua 62Hq + Bwt Aquaflex 38 (Optional)

    13.7.2 Spare part drawing: BWT bestaqua 62HQ + BWT aquaflex 38 (Optional)
  • Page 32: Spare Part List

    13.8 Spare part list Position BWT bestaqua 60, 61 and 62 Spare part No. Recommended Recommended spare parts replacement frequency High-pressure motor 451202495 High-pressure pump 451202490 Coupling for HP pump 451202485 Transport pump 454100070 Check valve ½" 200729004 Pressure tank...
  • Page 33 Options / accessories BWT Aquaflex 38 421094010 (extra 38l tank) Water feedthrough for 451202270 BWT aquaflex 38 BWT CRU 38 421090200 (concentrate reusable unit) Complete installation kit 656525125 RO comissioning toolbox 451409006 Pre-filter housing 7”, 3/4”, complete 321400017 For-filter, hus DUO 7”, ¾”, complete 321400027 Pre-filter cartridge 7”, 5µm...
  • Page 34: Disposal

    Member States requires electrical and electronic equipment to be collected separately from unsorted municipal waste so that it may be recycled. In Denmark and several other countries, BWT itself assumes responsibility for the return and conformant disposal of its electronic and electrical products. These products may not be placed with household waste or brought to collection centres run by local public disposal operations –...
  • Page 35: Declaration Of Conformity

    +45 43 600 500 - fax: +45 43 600 900 bwt@bwt.dk - www.bwt.dk herewith declares that: BWT bestaqua 60LT, 60HQ, 61LT, 61HQ, 62LT, 62HQ is in conformity with the provisions of the Machinery Directive (directive 2006/42/EC) is in conformity with the provisions of the following other EC directives...
  • Page 36 Fax: +33 1 4922 45 45 E-Mail: office@bwt.at E-Mail: bwt@bwt.de E-Mail: info@cillichemie.com E-Mail: bwt@bwt.fr BWT Belgium NM. BWE Česká Republika s.r.o. BWT Polska Sp. z o.o. BWT Hungária Kft. Leuvensesteenweg 633 Lipovo 196 -Cestlice ul. Polczyhska 116 Keleti út. 7. B-1930 Zaventem CZ-251 01 Říčany...

Table of Contents