Download Print this page

Daikin 2AMX40G3V1B Removal Procedure page 22

Hide thumbs Also See for 2AMX40G3V1B:

Advertisement

Compressor
Step
3
Unfasten the hooks with
a flat screwdriver and
remove the overload
protector.
Remove the 2 nuts of
4
the compressor.
Heat up the brazed part
5
of the discharge side
and disconnect.
Heat up the brazed part
6
of the suction side and
disconnect.
Lift up and remove the
7
compressor.
20
Procedure
(R7640)
(R7641)
(R7642)
(R7643)
Si121295
Points
Removal Procedure

Advertisement

loading

This manual is also suitable for:

2amx50g3v1b2mxs40h3v1b2mxs50h3v1b