Outdoor Fan / Fan Motor
Step
5
Turn the fan motor
fixing frame backward
and open the 2 hooks to
release the fan motor
lead wire.
Remove the 4 screws
6
and remove the fan
motor.
4
Procedure
Screw
Screw
(R7626)
When reassembling, put the
fan motor lead wire through
the back of the fan motor so
as not to be entangled with
the outdoor fan.
Lead wire
(R18758)