Avoiding damage from light sources and heat ......10 IP rating....................10 Avoiding damage from water and humidity........10 Avoiding damage from dust and airborne particles......11 Transportation and storage..............11 GLP Service and Support..............11 XPAR 12Z overview..................12 Installation ....................14 Permitted mounting options ...............14 Securing fixtures with a safety cable ..........14 Installing on a surface at any angle ..........15...
Page 4
Thermal ....................26 Included items..................27 Accessories (optional)................27 Dimensions and weight................27 10. Dimensions ....................28...
Read this manual carefully before installing, using or servicing the Fusion XPAR 12Z lighting fixture. If you have any doubts or questions about how to use the fixture safely, contact your GLP® supplier for assistance. Your GLP supplier will be happy to help.
● Check the GLP website at www.glp.de and make sure that you have the latest version of this manual. Check the fixture software version indicated on page 2 of this manual and then use the fixture’s control panel to check the version installed in the fixture.
- US power cable: 16 A, 14 AWG, UL-listed, E304117, SJT, 4.9 ft. - EU power cable: 16 A, 1.5 mm², H07RN-F, 1.5 m. Do not connect more than twelve (12) Fusion XPAR 12Z fixtures to power in a chain at 100- 120 V, 60 Hz.
● Do not place any optical components other than Fusion XPAR 12Z accessories from GLP onto the front of the fixture. ● Do not stick filters, masks or other materials onto the fixture. Do not block the light output in any way.
Do not attempt to use a fixture that is obviously damaged. ● Do not modify the fixture in any way not described in its user documentation. ● Install genuine GLP parts only. Fusion XPAR 12Z Quick Start and Safety Manual Rev. A...
(an IP65 rating means that the item is protected against the entry of water from rain, projections and low-pressure jets as well as the entry of dust). When assembling connectors and installing them on cable, follow the manufacturer’s and ensure that an Fusion XPAR 12Z Quick Start and Safety Manual Rev. A...
● Store the fixture in a dry location when not in use. GLP Service and Support Contact information for the nearest GLP Service and Support is available online at www.glp.de/en/service, by email at info@glp.de, or by telephone at the following numbers: ●...
XPAR 12Z overview 3. XPAR 12Z overview The Fusion XPAR 12Z from GLP is a powerful LED-based lighting fixture which uses a 120W RGBL (red, green, blue and lime) LED emitter. A motorized Fresnel lens provides variable zoom giving a beam angle from 6° – 44°.
Page 13
This Quick Start and Installation Manual gives a very basic overview of installation options and control functions. See the XPAR 12Z User Manual available for download from www.glp.de for full details of control, DMX tables, etc. Fusion XPAR 12Z Quick Start and Safety Manual Rev. A...
5. In a temporary installation, secure the fixture with a safety cable as described in ‘Securing fixtures with a safety cable’ on page 14 if there is any risk that the fixture will cause injury or damage if it falls. Fusion XPAR 12Z Quick Start and Safety Manual Rev. A...
1. Attach a suitable clamp to the mounting bracket of the XPAR 12Z as shown in Figure 4. 2. Attach the clamp to the truss or structure. 3. Secure the fixture with a safety cable as described in ‘Securing fixtures with a safety cable’ on page 14. Fusion XPAR 12Z Quick Start and Safety Manual Rev. A...
5. Ensure the fixture is located in a position where it will not form a trip hazard or cause injury if it falls over. If in doubt secure the fixture with a safety cable to an adjacent fixed point. Fusion XPAR 12Z Quick Start and Safety Manual Rev. A...
3. Ensure the fixture is located in a position where it will not form a trip hazard or cause injury if it falls over. If in doubt secure the fixture with a safety cable to an adjacent fixed point. Fusion XPAR 12Z Quick Start and Safety Manual Rev. A...
/ power plug on the supplied power cord / input cable. If you do this, check that the cord cap / plug is rated minimum 250 V, 16 A, Fusion XPAR 12Z Quick Start and Safety Manual Rev. A...
(12) fixtures in total. If you are using 200-240 V, 50 Hz AC mains power you can continue connecting fixtures Mains OUT to Mains IN until the chain contains a maximum of twenty-four (24) fixtures total. Fusion XPAR 12Z Quick Start and Safety Manual Rev. A...
Data + Not used Not used If you would like advice with planning and installing a DMX link, your GLP supplier will be happy to provide assistance. Installing optional barndoors An optional barndoor accessory is available for the XPAR 12Z that can be installed on the front of the fixture to control lateral light spill if required.
This would normally be used to hold diffusion or frost media to soften the light beam. The procedure to install the frame is the same as for the barndoor accessory above. Fusion XPAR 12Z Quick Start and Safety Manual Rev. A...
To start operation, check that nobody is looking into the front of the fixture, then apply power to the AC mains power circuit. To stop operation, shut down power to the AC mains power circuit. Fusion XPAR 12Z Quick Start and Safety Manual Rev. A...
The CTC and M/G shift channels modify Blue fine the color selected by the other Lime channels. Lime fine Color wheel A Control / Settings channel lets you configure the fixture remotely via DMX. M/G shift Fusion XPAR 12Z Quick Start and Safety Manual Rev. A...
Page 25
DMX Mode 6: Easy provides a simple operating mode with a fixed selection Dimmer of colors and zoom. Zoom Control A Control / Settings channel lets you Color Wheel configure the fixture remotely via DMX. Fusion XPAR 12Z Quick Start and Safety Manual Rev. A...
Control data in and thru (out): 5-pin XLR with sealing caps Construction Ingress protection rating: IP65 Fixture housing: Extruded aluminum Color: Black Thermal Cooling: Convection Minimum ambient temperature: -10° C (14° F) Maximum ambient temperature: 40° C (104° F) Fusion XPAR 12Z Quick Start and Safety Manual Rev. A...