Fire Safety And Protection From Burns - GLP Fusion XPAR 12Z Quick Start And Safety Manual

Table of Contents

Advertisement

German Light Products®
not reapply power until the fixture has been repaired and made safe by a technician
authorized by GLP.
● Check that all power distribution equipment, cables and connectors are in perfect
condition, rated for the electrical requirements of all connected devices, suitable for
their application and suitable for the installation environment.
● Use only TRUE1 compatible cable connectors for AC mains power input at the fixture's
Mains IN connector and for relaying AC mains power from one fixture's Mains OUT (Thru)
connector to another fixture's Mains IN connector.
● Use minimum 14 AWG or 1.5 mm
rated and temperature-rated to suit the application. In the USA and Canada the cables
must be UL-listed, type SJT or equivalent. In the EU the cables must be type H05VV-F or
equivalent.
● Do not connect devices to power in a chain if the total maximum current draw of all the
devices in the chain when added together will exceed the current rating of any cable
or connector used at any point in the chain. The supplied power input cable is rated as
follows:
- US power cable: 16 A, 14 AWG, UL-listed, E304117, SJT, 4.9 ft.
- EU power cable: 16 A, 1.5 mm², H07RN-F, 1.5 m.
Do not connect more than twelve (12) Fusion XPAR 12Z fixtures to power in a chain at 100-
120 V, 60 Hz.
Do not connect more than twenty-four (24) Fusion XPAR 12Z fixtures to power in a chain at
200-240 V, 50 Hz.
● The voltage and frequency at the Mains OUT socket are the same as the voltage and
frequency applied to the Mains IN socket. Only connect devices to the Mains Out socket
that accept this voltage and frequency.
● Fusion XPAR 12Z fixtures do not have a user-replaceable fuse. If you suspect that a fuse
has blown, disconnect the fixture from power and send it to a technician authorized by
GLP for repair.

Fire safety and protection from burns

● Do not operate the fixture if the ambient temperature (Ta) exceeds 40° C / 104° F.
● The surface of the fixture's casing can reach up to 90° C / 194° F during operation. Avoid
contact by persons and materials. Do not install the fixture in a location where there is a
risk of accidental contact. Allow the fixture to cool for at least 20 minutes before
handling
● Keep the fixture well away from flammable materials.
● Keep all combustible materials (e.g. fabric, wood, paper) at least 0.2 m / 8 in. away from
the fixture.
● Ensure that there is free and unobstructed airflow around the fixture.
Fusion XPAR 12Z Quick Start and Safety Manual Rev. A
Safety
power input and relay cables that are minimum 16 A-
2