Operation; Replacing The Lamps; Replacing The Fuse; Cleaning And Maintenance - EuroLite D-16 User Manual

Lighting effect
Hide thumbs Also See for D-16:
Table of Contents

Advertisement

Available languages

Available languages

OPERATION

After you connected the effect to the mains, the D-16 starts running. You can do without a controller as the
D-16 features a built-in microphone, which provides automatic sound control. You can adjust the sensitivity
with the rotary-control on the rearpanel.
REPLACING THE LAMP
During the operation, the lamp reaches temperatures of up to 600° C.
Before replacing the lamp, unplug mains lead and let the lamp cool down (approx. 5 minutes).
Do only replace the lamps with 120 V/300 W G-6,35 lamps.
Please refer to the instructions under "Installation of the lamps".
Procedure:
Step 1: Unscrew the fixation screw(s) of the service lid on top of the housing.
Step 2: Remove the service lid.
Step 3: Remove the old lamp from the lamp-socket.
Step 4: Insert the new 120 V/300 W G-6,35 lamp into the lamp-socket.
Step 5: Replace the service lid and tighten the screw(s).

REPLACING THE FUSE

If the lamp burns out, the fine-wire fuse of the device might fuse, too. Only replace the fuse by a fuse of
same type and rating (F 5 A, 250 V).
Before replacing the fuse, unplug mains lead.
Procedure:
Step 1: Unscrew the fuseholder on the rearpanel with a fitting screwdriver from the housing (anti-
clockwise).
Step 2: Remove the old fuse from the fuseholder.
Step 3: Install the new fuse in the fuseholder.
Step 4: Replace the fuseholder in the housing and fix it.

CLEANING AND MAINTENANCE

We recommend a frequent cleaning of the device. Please use a soft lint-free cloth moistened with any good
glass cleaning fluid. Never use alcohol or solvents!
There are no servicable parts inside the device. Maintenance and service operations are only to be carried
out by authorized dealers.
Should you need any spare parts, please use genuine parts.
Should you have further questions, please contact your dealer.
31ED9?>
The lam p has to be replaced when it is dam aged
or deform ed due to the heat!