Matelec FPC-32020 Owner's Operation Manual

Matelec FPC-32020 Owner's Operation Manual

Dual pump controller

Advertisement

P U M P
OWNER ' S
OPER A TIO N
MANUAL
Dual Pump Controller Installation and
Operating Instructions
MODEL: FPC-32020
DOC: FPC 32020
C O N T R O L
PUMP ON
PUMP ON
FAULT
FAULT
RAIN WATER
SYSTEM
TEST
MAINS WATER
SYSTEM FAULT
Rain / Mains Water Controller
DANGER - HIGH VOLTAGE
DO NOT REMOVE COVER. AUTHORIZED PERSONS ONLY
MAIN ISOLATOR
OFF
ON
REVISED: 031915

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FPC-32020 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Matelec FPC-32020

  • Page 1 C O N T R O L P U M P OWNER ’ S OPER A TIO N MANUAL Dual Pump Controller Installation and Operating Instructions MODEL: FPC-32020 PUMP ON PUMP ON FAULT FAULT RAIN WATER SYSTEM TEST MAINS WATER...
  • Page 2 WELCOME TO DUAL PUMP CONTROL design, engineering and manufacturing that has distinguished MATelec Products for decades. The controller incorporates the very latest in micro-processor technology, ensuring you, the owner/operator, of many years of functional, reliable and ‘user friendly’ operation. Please read this manual prior to installation and operation of the controller.
  • Page 3 INST ALLATIO N MOUNTING 1. Controller enclosure must be FRONT VIEW SIDE VIEW mounted in a vertical position. 2. Ensure mounting method does not compromise enclosure weather proof rating. 3. Ensure access to main isolator PUMP ON PUMP ON is not restricted. FAULT FAULT Mounting...
  • Page 4 OPER A TIO N This controller can perform control functions for most Dual Pump pumping applications. It is more than likely that the con- There are 6 DIP switches located on the lower side of the control module, which allows for selecting “mode” and “feature” options, as per the following table: DIP Switch Position...
  • Page 5 The basic logic on which a High or Low Level Alarm is determined, is set out in the Table below: Input 1 Input 2 Input 3 Input 4 Pump Alarm State Low Level Pump Stop Pump Start High Level Closed Open/Closed Open Open...
  • Page 6 In pressure pump mode some of the optional features are disabled, including maximum run alternation, anti-seize and maximum idle timers. Mode ‘Current Loop’: Level Transducer (4-20mA) Configuration In order to activate current loop mode the enclosure must be opened and jumper J10 moved to the “current loop enabled”...
  • Page 7 CIR C U IT DI A GRA M PUMP 1 PUMP 2 PUMP ON PUMP ON FAULT FAULT CONTACTOR 12Vdc COILS A1 A2 TOL 1 TOL 2 KEYPAD CONNECTION PUMP 1 PUMP 2 PUMP 1 PUMP 2 FAULT FAULT 240V 10A MAX RAIN WATER PUMP SUPPLY...
  • Page 8 Rain / Mains Water Controller will confirm if on) the pump is set to Manual Pumping Mode INSTALLATION DATE: DISTRIBUTED BY: DANGER - HIGH VOLTAGE DO NOT REMOVE COVER. AUTHORIZED PERSONS ONLY SERIAL NUMBER: MANUFACTURED BY MATelec AUSTRALIA EMAIL: info@matelecaustralia.com.au...