  • Page 1 Operating Instructions Ti22 ProX Chilled Water Marine Air-Conditioning Systems English...
  • Page 2 Selecting the setpoint temperature ...... 4 Setting the fan speed.......... 5 Chiller unit Home screen without cabin control.. 5 System settings........ 5 Setting level 1............ 5 Maintenance........ 5 10 Status / Error message table .... 7 2112899A OI Ti22 ProX...
  • Page 3: About This Document

    NOTE All measurements are in mm, unless stated otherwise. Safety Intended use The purpose of Ti22 ProX is to provide heating and cooling on ships. The Ti22 ProX meets the current state of technology and recog- nized safety rules. Fig. 1 Design 1...
  • Page 4: Operation

    Decrease values low 15 °C and above 40 °C in heating mode. The current cold Automatic fan control water temperature at the outlet of the Ti22 ProX can be reques- ted in setting level 2 (crew menu). Previous See Setting level 2.
  • Page 5: System Settings

    3. Tap Timer. The setting window for this function opens up. Fig. 4 If you operate the Ti22 ProX chiller unit without any connected air handlers, then you can select an alternative Home screen, which displays the current operating values for the chiller unit.
  • Page 6 Check the functioning of the system. Run the Ti22 ProX in cooling and heating mode for at least 10 minutes. Let the compressor start 3 to 4 times in each mode.
  • Page 7: Heating Mode

    If this does not solve the problem, small cable cross sections, overloading or please contact your authorised low power generator output. Webasto Marine dealer or service partner. A01 - Low pressure 2x flashing, Pressure switch defective or power circuit in-...
  • Page 8 Poor air or water flow, soiled or circulation Secure adequate air or water flow. ing or heating capacity. blocked. Refrigerant shortage. Please contact your authorised Webasto Marine dealer or a refriger- ant specialist. 8 / 10 2112899A OI Ti22 ProX...
  • Page 9 Select screen settings “Chiller unit despite with cabin control (Yes)”. cabin temperatures Now select automatic mode (F3/F4, needing heating see Screen settings (level 2)) mode (or cooling mode). 2112899A OI Ti22 ProX 9 / 10...
  • Page 10 These are the original instructions. The English language is binding. You can request your language if it is missing. The telephone number of each country can be found in the Webasto ser- vice centre leaflet or the website of the respective Webasto representative of your country.