Video entry kit

Advertisement

Quick Links

VIDEO ENTRY KIT
FB01044-EN
VA/01
OPALE
DVC/01
PEV/01
DVC/01 ME
INSTALLATION MANUAL
EVKIT
EN English

Advertisement

loading

Summary of Contents for CAME BPT EVKIT

  • Page 1 VIDEO ENTRY KIT FB01044-EN VA/01 OPALE DVC/01 PEV/01 DVC/01 ME INSTALLATION MANUAL EVKIT EN English...
  • Page 2 General Notes • Read the instructions carefully before beginning the installation and carry out the actions as specified by the manufacturer. • The installation, programming, commissioning and mainte- nance of the product must only be carried out by qualified tech- nicians, properly trained in compliance with the regulations in force, including health and safety measures and the disposal of packaging.
  • Page 3 To release the unit from the metal support, press the plastic hook and lift the terminal G. Technical data Type Maximum current draw (mA) Current draw in stand-by mode (mA) < 1 Single LED current draw (mA) Storage temperature (°C) -25 to +70 Video standard PAL/NTSC...
  • Page 4 Setting melodies ☞ All the programming stages described below must be carried out in sequence: 1- Going into Programming. 5 times in 5 secs A. Press button beep A short beep confirms that you have entered programming mode. 2- Programming the melody associated with a call from the entry panel. To listen to the melodies in sequence, press key B.
  • Page 5 OPALE Wall-mounted installation Separate the unit body from the frame A. Fasten the OPALEKP wall-mounting support (optional) to the recessed box using the screws provided; the support is com- patible with the following recessed box models: round 60 mm Ø, 503 rectangular, 506E rectangular, and OPALESI (optional). To guarantee better stability, fasten the support with the screws and plugs provided 1.
  • Page 6 Recessed installation on plasterboard wall D Hold the box up against the plasterboard wall and mark the 4 reference points for installation 1. Make 4 holes, 10 mm in diameter, at the reference points. Cut the plasterboard to make a compartment for the box in the wall OPALEKP Remove the 2 tabs on the box as shown in the figure C.
  • Page 7 Terminal board F Local power supply – 16-18 VDC BUS line input 16-18VDC Doorbell – Alarm input Closing resistance (CL.RES) G The jumper should be inserted in the last device in the line only. Master/Slave selector (SKM) H If two or more receivers have been configured to answer the same call, the preview image of the caller is shown only on the master device(s).
  • Page 8 VA/01 Installation The power supplier must ALWAYS be installed horizontally. The device can be installed on a DIN rail (EN 50022) in an appro- priate electric panel or it may be wall-mounted using the protec- tive terminal covers. 43,5 For disassembly, proceed as shown in figure B-C. For the overall dimensions see figure A.
  • Page 9 Ð RS232 MINI PROG +12V BIN1 BIN3 BOUT BIN2 RFID PROG RFID PROG Jumper (**) Functions D Ð M1 Ð M1 Ð M1 Terminal boards A RFID RFID RFID Mains PROG PROG PROG Morsettiera M1 Default Code entry Code deletion Aux 1 output Open Collector max 100 mA +12V Common Aux 2 output Open Collector max 100 mA...
  • Page 10 Absorption With entry panel ‘on standby’ With solenoid lock ‘on’ With surveillance camera on 130 mA 130 mA 35 mA 320 mA 500 mA VA/01 VA/01 VA/01 VA/01 500 mA 500 mA 500 mA 320 mA 130 mA 130 mA 320 mA 500+130+320+500=1450 mA >1100 mA 130+320+500=950 mA <1100 mA...
  • Page 11 DVC/01 ME Wall mounting fix the given plugs and screw the entry panel A at the desired height considering the position of the lens of the camera B. Run the hose with the system conductors as shown in figure A. Extract the plastic terminal cover and wire the connections C.
  • Page 12 Recessed installation Install the recessed box at the desired height considering the position of the lens of the camera B, but in advance, run the hose with the system conductors through one of the breaking points E1. During installation of the recessed box it is possible to avoid any deformation by using the provided spacer E2.
  • Page 13 Side-by-side recessed installation Entry panels can be placed side-by-side both horizontally and vertically M locking the boxes with one another. Before installing them, break the lower and side breaking points as highlighted in figure M in order to run the connection ca- ble from the push button entry panel to the main/previous entry panel.
  • Page 14 Accessories P 1 Single height button DPS; 2 Double height button DPH; 3 Double DPD button; 4 Single height plu DTS ME; E Double height stopper DTH ME; F Access control module with keyboard DNA ME; G Access control module with RFID reader DRFID, 8 Recessed box DSI;...
  • Page 15 Functions R Terminal boards 1 Power supply 14-18 VDC – BOUT Riser Terminal boards 2 MINI USB Solenoid lock 12 V - 1 A max – DATI Door lock release button (NA) PROG Door contact input (NC) – Ground Entry panel enabling output (active towards earth) BOUT –...
  • Page 16 BIN1 BIN2 BIN3 BOUT +12V – + MINI USB DATI PROG – VLS/300 BOUT +12V BIN1 BIN2 BIN3 BOUT +18V VLS/101 MINI USB DATI PROG BOUT...
  • Page 17 Manual programming of entry panels It is possible to programme only one or several audio/video entry panels that have the same calls (unless "blind units" are used that disable one or more of them). It is possible to programme entry panels (connected to the same power supply) with different types of keys, still respecting the sequence shown on the left.
  • Page 18 PROGRAMMING ENTRY PANELS First Programming with ONE entry panel Entering Programming Mode. Press the PROG key on the power supply 1 until the PROG LED lights up. If the PROG LED immediately goes out, this indicates a malfunction PROG PROG >3’’...
  • Page 19 From the default settings it is possible to scroll through the following ones I by press- ing the AUX1 key or to go back to the previous ones with the AUX2 key J: the 100 ° 82 ° setting is saved automatically. 1÷9 72 °...
  • Page 20 Programming the call keys. Lift the receiver (if present) of the extension that you want to programme then press the door lock release and AUX2 7 buttons. On the entry panel, press the call key to associate with the internal extension 8: an acoustic signal will confirm that the setting was stored.
  • Page 21 Exiting Programming. Briefly press the PROG key on the power supply 5: the PROG LEDs and the LEDs on the entry panels will go out. If no action is performed, the proce- PROG PROG <1’’ dure will end automatically after 30 minutes. Programming Type of Keys.
  • Page 22 Programming with DNA For this type of configuration of Entry For this type of configuration of Entry panels refer panels refer to the procedures already to the procedures described below. described. Entering Programming Mode. Press the PROG key on the power supply for more than 3 seconds 1.
  • Page 23 Entering Codes and Tags Position the power supply's PROG RFID jumper at “+” 1: the power supply's PROG LED will flash slowly along with the message LEDs with the configuration in fig. 2. If the LEDs immediately go out it means there is a malfunction in the connections between Ð...
  • Page 24 Badge. Bring a badge/tag up to the beep beep reader of any entry panel that has already been addressed 3 and, after the confir- mation beep, repeat this once again to confirm 4: ALL the badges relating to the GROUP will be deleted. Codes.
  • Page 25 Programming an intercom group The intercom group must be programmed ONLY AFTER assigning the key or the call code to all the internal extensions. - Press and hold down the power supplier PROG key for at least 25 seconds until the PROG LED starts to flash quickly 1.
  • Page 26 At the end, return the RFID PROG jumper to its standby position 3: the procedure will NOT end automatically! Ð RFID PROG PROG A group of intercommunicating internal extensions can be programmed with the VA/01 power supplier following the previously described procedure.
  • Page 27 The product complies with the relevant directives in force. Decommissioning and disposal. Dispose of the packaging and the device responsibly at the end of its life cycle, in compliance with the laws in force in the country where the product is used. The recyclable components are marked with a symbol and the material’s ID marker. THE DATA AND INFORMATION SHOWN IN THIS MANUAL ARE TO BE CONSIDERED AS SUBJECT TO CHANGE AT ANY TIME AND WITHOUT THE NEED FOR ANY ADVANCE WARNING.
  • Page 28 CAME S.p.A. Via Martiri Della Libertà, 15 31030 Dosson di Casier - Treviso - Italy tel. (+39) 0422 4940 - fax. (+39) 0422 4941...