  • Page 1 BACnet Server Modbus RTU Master and Modbus TCP Client USER MANUAL Issue date: 08/2021 r1.10 ENGLISH...
  • Page 2 HMS Industrial Networks reserves the right to modify its products in line with its policy of continuous product development. The information in this document shall therefore not be construed as a commitment on the part of HMS Industrial Networks and is subject to change without notice.
  • Page 3 ORDER CODE LEGACY ORDER CODE INBACMBM1000000 IBBACMBM1000000 INBACMBM2500000 IBBACMBM2500000 INBACMBM6000000 IBBACMBM6000000 INBACMBM1K20000 IBBACMBM1K20000 INBACMBM3K00000 IBBACMBM3K00000 © HMS Industrial Networks S.L.U - All rights reserved URL https://www.intesis.com This information is subject to change without notice 3 / 41...
  • Page 4: Table Of Contents

    Connection to the configuration tool ....................31 7 Status LEDs and push buttons ......................32 8 Set-up process and troubleshooting ...................... 33 Pre-requisites ..........................33 Intesis MAPS. Configuration & monitoring tool for Intesis BACnet series ........33 7.2.1 Introduction ..........................33 7.2.2 Connection ..........................
  • Page 5 BACnet Server – Modbus Client User Manual r1.10 eng © HMS Industrial Networks S.L.U - All rights reserved URL https://www.intesis.com This information is subject to change without notice 5 / 41...
  • Page 6: Description

    This document describes the integration of Modbus RTU and Modbus TCP installations into BACnet MSTP or BACnet IP compatible devices and systems using the Intesis BACnet Server – Modbus Client gateway. The aim of this integration is to make accessible Modbus system signals and resources from a BACnet based control system or device, as if it was a part of the own BACnet system and vice-versa.
  • Page 7 User Manual r1.10 eng Integration of Modbus RTU Slaves or Modbus TCP Servers to BACnet IP control and monitoring systems © HMS Industrial Networks S.L.U - All rights reserved URL https://www.intesis.com This information is subject to change without notice 7 / 41...
  • Page 8: Functionality

    Number of Modbus Slave Up to 255 Modbus RTU devices per TCP/RTU Slave devices devices supported by the device node © HMS Industrial Networks S.L.U - All rights reserved URL https://www.intesis.com This information is subject to change without notice 8 / 41...
  • Page 9: Protocol Implementation Conformance Statement

    Point-To-Point, EIA 232 (Clause 10), baud rate(s): Point-To-Point, modem, (Clause 10), baud rate(s): LonTalk, (Clause 11), medium: _____ Other: © HMS Industrial Networks S.L.U - All rights reserved URL https://www.intesis.com This information is subject to change without notice 9 / 41...
  • Page 10: Device Address Binding

    If this product is a communication gateway, describe the types of non-BACnet equipment/network(s) that the gateway supports: Modbus RTU (EIA485) and TCP networks. © HMS Industrial Networks S.L.U - All rights reserved URL https://www.intesis.com This information is subject to change without notice...
  • Page 11: Bacnet Interoperability Building Blocks Supported (Bibbs)

    DM-DCC-B Device Management - DeviceCommunicationControl–B DeviceCommunicationControl DM-TS-B Device Management - TimeSynchronization–B TimeSynchronization DM-RD-B Device Management - ReinitializeDevice–B ReinitializeDevice © HMS Industrial Networks S.L.U - All rights reserved URL https://www.intesis.com This information is subject to change without notice 11 / 41...
  • Page 12: Service Types

    Initiate I-Have Initiate UnconfirmedCOVNotification Initiate UnconfirmedEventNotification Unconfirmed Services Execute TimeSynchronization Execute Who-Has Execute / Initiate Who-Is Execute GetEventInformation © HMS Industrial Networks S.L.U - All rights reserved URL https://www.intesis.com This information is subject to change without notice 12 / 41...
  • Page 13: Objects

    The objects supported are shown in the table below. Object Type Analog-Input Analog-Output Analog-Value Binary-Input Binary-Output Binary-Value Calendar Device Multistate-Input Multistate-Output Multistate-Value Notification-Class Schedule Trend-Log Trend-Log-Multiple © HMS Industrial Networks S.L.U - All rights reserved URL https://www.intesis.com This information is subject to change without notice 13 / 41...
  • Page 14: Objects And Properties

    Max_Info_Frames * Unsigned List of Device_Address_Binding NULL (empty) BACnetAddressBinding Database_Revision Unsigned BACnetArray[N] of Configuration_Files BACnetObjectIdentifier Last_Restore_Time BACnetTimeStamp Backup_Failure_Timeout Unsigned16 © HMS Industrial Networks S.L.U - All rights reserved URL https://www.intesis.com This information is subject to change without notice 14 / 41...
  • Page 15 BOOLEAN Interval_Offset Unsigned Profile_Name CharacterString * Only available when MSTP is used ** Configurable through the configuration tool. © HMS Industrial Networks S.L.U - All rights reserved URL https://www.intesis.com This information is subject to change without notice 15 / 41...
  • Page 16: Analog Input Object Type

    Only available when specific object has a Notification Class configured Only available in some models after activations on the configuration tool, review the specific model manual for details. © HMS Industrial Networks S.L.U - All rights reserved URL https://www.intesis.com This information is subject to change without notice...
  • Page 17: Analog Output Object Type

    Only available when specific object has a Notification Class configured Only available in some models after activations on the configuration tool, review the specific model manual for details © HMS Industrial Networks S.L.U - All rights reserved URL https://www.intesis.com This information is subject to change without notice...
  • Page 18: Analog Value Object Type

    Only available when specific object has a Notification Class configured Only available in some models after activations on the configuration tool, review the specific model manual for details © HMS Industrial Networks S.L.U - All rights reserved URL https://www.intesis.com This information is subject to change without notice...
  • Page 19: Binary Input Object Type

    Only available when specific object has a Notification Class configured Only available in some models after activations on the configuration tool, review the specific model manual for details © HMS Industrial Networks S.L.U - All rights reserved URL https://www.intesis.com This information is subject to change without notice...
  • Page 20: Binary Output Object Type

    Only available when specific object has a Notification Class configured Only available in some models after activations on the configuration tool, review the specific model manual for details © HMS Industrial Networks S.L.U - All rights reserved URL https://www.intesis.com This information is subject to change without notice...
  • Page 21: Binary Value Object Type

    Only available when specific object has a Notification Class configured Only available in some models after activations on the configuration tool, review the specific model manual for details © HMS Industrial Networks S.L.U - All rights reserved URL https://www.intesis.com This information is subject to change without notice...
  • Page 22: Multistate Input Object Type

    Only available when specific object has a Notification Class configured Only available in some models after activations on the configuration tool, review the specific model manual for details © HMS Industrial Networks S.L.U - All rights reserved URL https://www.intesis.com This information is subject to change without notice...
  • Page 23: Multistate Output Object Type

    Only available when specific object has a Notification Class configured Only available in some models after activations on the configuration tool, review the specific model manual for details © HMS Industrial Networks S.L.U - All rights reserved URL https://www.intesis.com This information is subject to change without notice...
  • Page 24: Multistate Value Object Type

    Only available when specific object has a Notification Class configured Only available in some models after activations on the configuration tool, review the specific model manual for details © HMS Industrial Networks S.L.U - All rights reserved URL https://www.intesis.com This information is subject to change without notice...
  • Page 25: Notification Class Object Type

    Configurable through Config Tool Object_Type BACnetObjectType CALENDAR (6) Present_Value BOOLEAN BACnetLIST of Date_List BACnetCalendarEntry BACnetARRAY[N] of Property_List BACnetPropertyIdentifier © HMS Industrial Networks S.L.U - All rights reserved URL https://www.intesis.com This information is subject to change without notice 25 / 41...
  • Page 26: Schedule Object Type

    BACnetLIST of List_Of_Object_Property_Refer BACnetDeviceObjectProper ences tyReference Priority_For_Writing Unsigned(1..16) Status_Flags BACnetStatusFlags Reliability BACnetReliability Out_Of_Service BOOLEAN FALSE BACnetARRAY[N] of Property_List BACnetPropertyIdentifier © HMS Industrial Networks S.L.U - All rights reserved URL https://www.intesis.com This information is subject to change without notice 26 / 41...
  • Page 27: Trend Log Object Type

    PropertyReference Log_Interval Unsigned BACnetARRAY[N] of Property_List BACnetPropertyIdentifier * Only available when specific object has a Notification Class configured © HMS Industrial Networks S.L.U - All rights reserved URL https://www.intesis.com This information is subject to change without notice 27 / 41...
  • Page 28: Trend Log Multiple Object Type

    Log_Interval Trigger BOOLEAN BACnetARRAY[N] of Property_List BACnetPropertyIdentifier * Only available when specific object has a Notification Class configured © HMS Industrial Networks S.L.U - All rights reserved URL https://www.intesis.com This information is subject to change without notice 28 / 41...
  • Page 29: Connections

    Connect a USB storage device (not a HDD) if required. Check the user manual for more information. Ensure proper space for all connectors when mounted (see section 10). © HMS Industrial Networks S.L.U - All rights reserved URL https://www.intesis.com This information is subject to change without notice...
  • Page 30: Powering The Device

    Note: BACnet MSTP only available when port B not used for Modbus RTU integration. Selectable by Intesis MAPS. © HMS Industrial Networks S.L.U - All rights reserved URL https://www.intesis.com...
  • Page 31: Connection To Modbus

    Ethernet: Using the Ethernet port of Intesis. • USB: Using the console port of Intesis, connect a USB cable from the console port to the PC. © HMS Industrial Networks S.L.U - All rights reserved URL https://www.intesis.com This information is subject to change without notice...
  • Page 32: Status Leds And Push Buttons

    Intesis MAPS software under configuration/USB host Button B – BACnet Sends to Broadcast I-Am message (Using BACnet/MSTP protocol) © HMS Industrial Networks S.L.U - All rights reserved URL https://www.intesis.com This information is subject to change without notice 32 / 41...
  • Page 33: Set-Up Process And Troubleshooting

    Link to download the configuration tool. • USB Console cable to communicate with Intesis. • Product documentation. Intesis MAPS. Configuration & monitoring tool for Intesis BACnet series 7.2.1 Introduction ® Intesis MAPS is a Windows compatible software developed specifically to monitor and configure Intesis BACnet series.
  • Page 34 BACnet Server – Modbus Client User Manual r1.10 eng Figure 8.1 MAPS connection © HMS Industrial Networks S.L.U - All rights reserved URL https://www.intesis.com This information is subject to change without notice 34 / 41...
  • Page 35: Configuration Tab

    More information on each parameter and how to configure it can be found in the Intesis MAPS user manual. © HMS Industrial Networks S.L.U - All rights reserved URL https://www.intesis.com This information is subject to change without notice...
  • Page 36: Sending The Configuration To Intesis

    3.- Press the Send File button to send the binary file to the Intesis device. The process of file transmission can be monitored in the Intesis Communication Console window. Intesis will reboot automatically once the new configuration is loaded. © HMS Industrial Networks S.L.U - All rights reserved URL https://www.intesis.com This information is subject to change without notice...
  • Page 37: Diagnostic

    Signals Viewer to simulate the BMS behavior or to check the current values in the system. © HMS Industrial Networks S.L.U - All rights reserved URL https://www.intesis.com This information is subject to change without notice...
  • Page 38 User Manual r1.10 eng Figure 8.5 Diagnostic More information about the Diagnostic section can be found in the Configuraion Tool manual. © HMS Industrial Networks S.L.U - All rights reserved URL https://www.intesis.com This information is subject to change without notice...
  • Page 39: Set-Up Procedure

    In case there is no communication activity between Intesis and the BACnet and/or Modbus devices, check that those are operative: check the baud rate, the communication cable used to connect all devices and any other communication parameter. © HMS Industrial Networks S.L.U - All rights reserved URL https://www.intesis.com This information is subject to change without notice...
  • Page 40: Electrical & Mechanical Features

    ON: 120 Ω termination active Switch B Off: 120 Ω termination inactive SWB) Position 2-3: ON: Polarization active Off: Polarization inactive © HMS Industrial Networks S.L.U - All rights reserved URL https://www.intesis.com This information is subject to change without notice 40 / 41...
  • Page 41: Dimensions

    Recommended available space for its installation into a cabinet (wall or DIN rail mounting), with space enough for external connections 100 mm (h) 130 mm (d) 100 mm (w) © HMS Industrial Networks S.L.U - All rights reserved URL https://www.intesis.com This information is subject to change without notice 41 / 41...