HMS Intesis INMBSFGL016O000 User Manual

HMS Intesis INMBSFGL016O000 User Manual

Modbus server fujitsu vrf air conditioning
Hide thumbs Also See for Intesis INMBSFGL016O000:

Advertisement

Quick Links

Fujitsu VRF Air Conditioning
USER MANUAL
Issue date: 02/2020 r1.0 ENGLISH

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Intesis INMBSFGL016O000 and is the answer not in the manual?

Questions and answers

Summary of Contents for HMS Intesis INMBSFGL016O000

  • Page 1 Fujitsu VRF Air Conditioning USER MANUAL Issue date: 02/2020 r1.0 ENGLISH...
  • Page 2 HMS Industrial Networks reserves the right to modify its products in line with its policy of continuous product development. The information in this document shall therefore not be construed as a commitment on the part of HMS Industrial Networks and is subject to change without notice.
  • Page 3 Gateway for the integration of Fujitsu VRF systems into Modbus (RTU and TCP) systems. ORDER CODE LEGACY ORDER CODE INMBSFGL016O000 FJ-AC-MBS-16 © HMS Industrial Networks S.L.U - All rights reserved https://www.intesis.com This information is subject to change without notice 3 / 25...
  • Page 4: Table Of Contents

    6. Dimensions ................................. 22 7. AC Unit Types compatibility..........................23 8. Error codes for Indoor and Outdoor Units ......................24 © HMS Industrial Networks S.L.U - All rights reserved https://www.intesis.com This information is subject to change without notice 4 / 25...
  • Page 5: Description

    This document assumes that the user is familiar with Modbus and Fujitsu technologies and their technical terms. Integration of Fujitsu’s compatible systems into Modbus systems © HMS Industrial Networks S.L.U - All rights reserved https://www.intesis.com This information is subject to change without notice...
  • Page 6: Functionality

    • Status Outdoor Unit • Status • Command Indoor Unit • Communication status • Command General signals (all units) © HMS Industrial Networks S.L.U - All rights reserved https://www.intesis.com This information is subject to change without notice 6 / 25...
  • Page 7: Capacity Of Intesis

    (with maximum capacity). Their order codes are: ▪ INMBSFGL016O000: Model supporting up to 16 indoor units © HMS Industrial Networks S.L.U - All rights reserved https://www.intesis.com This information is subject to change without notice 7 / 25...
  • Page 8: Modbus Interface

    TCP port to use (default is 502) and keep alive period must be configured. IP settings of Intesis (DHCP status, own IP, net mask and default gateway) must be configured as well. © HMS Industrial Networks S.L.U - All rights reserved https://www.intesis.com...
  • Page 9: Modbus Address Map

    Fujitsu VRF configuration in MAPS, from 0 to 31 5-60% 6-50% 7-40% 0-Not forced (ID+1)*25+10000+1 Forced Off 1-Forced off © HMS Industrial Networks S.L.U - All rights reserved https://www.intesis.com This information is subject to change without notice 9 / 25...
  • Page 10 1-Alarm (ID+1)*100 +17 Filter Alarm Reset 1-Reset 0-No error (ID+1)*100 +18 Communication Error IU 1-Error 0-OFF (ID+1)*100 +19 Emergency © HMS Industrial Networks S.L.U - All rights reserved https://www.intesis.com This information is subject to change without notice 10 / 25...
  • Page 11 1-Not allow 0-Allow (ID+1)*100 +23 Allow Setpoint from RC 1-Not allow 0-Thermo OFF (ID+1)*100 +24 Thermo off 1-Thermo ON © HMS Industrial Networks S.L.U - All rights reserved https://www.intesis.com This information is subject to change without notice 11 / 25...
  • Page 12: Connections

    Connect a USB storage device (not an HDD) if required. Ensure proper space for all connectors when mounted (see IMENSIONS © HMS Industrial Networks S.L.U - All rights reserved https://www.intesis.com This information is subject to change without notice 12 / 25...
  • Page 13: Power Device

    Ethernet: Using the Ethernet port of Intesis. • USB: Using the console port of Intesis, connect a USB cable from the console port to the PC. © HMS Industrial Networks S.L.U - All rights reserved https://www.intesis.com This information is subject to change without notice...
  • Page 14: Set-Up Process And Troubleshooting

    Connectors, connection cables, PC for the Configuration Tool usage and other auxiliary material, if needed, are not supplied by Intesis for this standard integration. Items supplied by HMS Networks for this integration are: • Intesis gateway.
  • Page 15: Configuration Tab

    • Available values: 1200, 2400, 4800, 9600,19200, 38400, 57600, 115200 bps. 3.3 Data Type. Set the Data-bit/parity/stop-bit. Default: 8bit/None/1. © HMS Industrial Networks S.L.U - All rights reserved https://www.intesis.com This information is subject to change without notice 15 / 25...
  • Page 16: Fujitsu Configuration

    Refrigerant system: as is defined in the VRF network for this certain unit. Description. Descriptive name to easy identification of the unit (for example, ‘living room floor 1 unit’). © HMS Industrial Networks S.L.U - All rights reserved https://www.intesis.com This information is subject to change without notice...
  • Page 17: Signals

    All available Modbus registers, its corresponding description and other main parmaters are listed in the signals tab. Figure 4.2.6.7 Intesis MAPS Signals tab © HMS Industrial Networks S.L.U - All rights reserved https://www.intesis.com This information is subject to change without notice...
  • Page 18: Sending The Configuration To Intesis

    Signals Viewer to simulate the BMS behavior or to check the current values in the system. Figure 4.2.8.9 Diagnostic © HMS Industrial Networks S.L.U - All rights reserved https://www.intesis.com This information is subject to change without notice...
  • Page 19: Set-Up Procedure

    Modbus devices, check that those are operative: check the baud rate, the communication cable used to connect all devices and any other communication parameter. © HMS Industrial Networks S.L.U - All rights reserved https://www.intesis.com This information is subject to change without notice...
  • Page 20 Modbus Server – FUJITSU VRF Intesis User Manual r1.0 EN Figure 4.2.9.10 Enable COMMS © HMS Industrial Networks S.L.U - All rights reserved https://www.intesis.com This information is subject to change without notice 20 / 25...
  • Page 21: Electrical & Mechanical Features

    Off: 120 Ω termination inactive (default) (SWB) Position 2-3: ON: Polarization active Off: Polarization inactive (default) 130 mm (d) 100 mm (w) © HMS Industrial Networks S.L.U - All rights reserved https://www.intesis.com This information is subject to change without notice 21 / 25...
  • Page 22: Dimensions

    Recommended available space for its installation into a cabinet (wall or DIN rail mounting), with space enough for external connections 100 mm (h) 100 mm (w) 130 mm (d) © HMS Industrial Networks S.L.U - All rights reserved https://www.intesis.com This information is subject to change without notice 22 / 25...
  • Page 23: Ac Unit Types Compatibility

    User Manual r1.0 EN 7. AC Unit Types compatibility The gateway is compatible with Fujitsu VRF units after the VRF-II series (included). © HMS Industrial Networks S.L.U - All rights reserved https://www.intesis.com This information is subject to change without notice...
  • Page 24: Error Codes For Indoor And Outdoor Units

    Discharge temperature 2 abnormal Compressor temperature abnormal Pressure abnormal 1 Pressure abnormal 2 Special operation error Ambient temperature abnormal Main PCB error © HMS Industrial Networks S.L.U - All rights reserved https://www.intesis.com This information is subject to change without notice 24 / 25...
  • Page 25 Outdoor heat exchanger temperature abnormal Connection unit number error in wired remote controller system Indoor unit communication circuit (wired remote controller) error © HMS Industrial Networks S.L.U - All rights reserved https://www.intesis.com This information is subject to change without notice...

This manual is also suitable for:

Intesis fj-ac-mbs-16

Table of Contents