Care, maintenance and disposal

General

The cleaning device generally needs no maintenance. However, to keep the clean-
ing device in good working condition for years to come, several points on care
and maintenance must be observed.
Before each
-
start-up
-
-
-
-
-

Daily

Danger from cleaning agents containing solvents.
This can result in damage to property.
1

Weekly

Danger from cleaning agents containing solvents.
This can result in damage to property.
1
2

Every 6 months

1

As necessary

Open the device and
1
2
3
Check fill level in parting agent container and top up if necessary
Check fill level in parting agent spatter tray and empty if necessary
Check cleaning cutter for wear and replace if necessary
Empty the cleaning device spatter tray
If fitted, empty the wire cutter tray
Carry out a general visual inspection of the cleaning device and make sure
that any damage is repaired immediately (before start-up)
CAUTION!
Only use solvent-free cleaning products on the cleaning device.
Remove parting agent deposits and dirt from device
CAUTION!
Only use solvent-free cleaning products on the parting agent container.
Check the parting agent container for soiling and clean if necessary
Blow through suction filter in parting agent container using compressed air
from the inside outwards through the suction hose (for more detailed inform-
ation see section
Starting up the parting agent nebuliser
Open the device and check the pneumatic valves for
-
Leaks
-
The secure seating of all screws
-
The secure seating of all screw joints on the pneumatic valves
Clean inside of device using dry reduced compressed air
Lightly oil the lifting device cylinder guides
Restore the original condition of the device
from page 44)