Fitting The Clamping System For Welding Torches With Internally Routed Coolant Lines; Tools Required; Removing The Existing Clamping System - Fronius Robacta Reamer V Twin Operating Instructions Manual

Hide thumbs Also See for Robacta Reamer V Twin:
Table of Contents

Advertisement

Fitting the clamping system for welding torches
with internally routed coolant lines

Tools required

-
-
Removing the
existing clamp-
ing system
Torx® screwdriver, TX25
3 mm & 5 mm Allen key
1
1
2
4
Undo the 5 Allen screws
1
size 3 mm
Remove the housing cover
2
Undo the 2 Allen screws
3
size 5 mm
Remove the 3-part clamping
4
device element