3
Set up the temperature control handle
<Single tap type>
1. Turn the tap on anti-clockwise at the maximum degree.
2. Turn the temperature control handle until the water
temperature reaches approx. 40 ℃, regardless its
scale marks.
pressing the lock button.
3. Remove the cap and screw from the temperature
control handle, and take the handle out of the unit.
Do not turn the handle when taking it out.
Caution
tool to remove the cap, cover the cap with a plastic
bag beforehand.
Make sure the tool does not scratch the coated
surface of the temperature control handle and the cap.
peeled, contact your closest dealer.
The damaged coated surface might cause injury
while in use of the equipment.
4. Put back the temperature control handle to the unit,
so that the scale mark of 40 on the handle matches
to the line on the thermostat.
5. Check if the water temperature is approx.40 ℃.