Wall Fittings - Takara Belmont MAJOLICA PORTO EX-SB 1 Series Installation Instructions Manual

Table of Contents

Advertisement

1

Wall fittings

1
Attach stop valve
1. Check the position of drainage pipe for
floor, based on the installation position
of the basin (Basin in the centre).
are attached on the wall.
riser, hot water supply and water supply
refer to the dimentions. (See page 2)
2. Mark the position to fix the basin
bracket and hooks.
other equipment,
if the stop valves do not have a filter inside,
change it to the provided stop valves
with a filter.
<Single tap type>
3. Apply a seal tape (PTFE tape) to the screws of the
stop valves.
4. Attach the covers(small) on the stop valves
and install them on to the wall. Make sure
the taped surface faces the ceiling.
stop valve before the installation.
5. Secure the thermostat on to the water stop
valve
Mount the stop valves in the way that
―‐― lines become vertical to the floor.
<Double tap type>
3. Apply a seal tape (PTFE tape) to the screws of the
stop valves.
4. Attach the covers(small) on the water pipes
and install the stop valves in the way that
the flexible pipes connecting ports face the ceiling.
Mount the stop valves in the way that
―‐― lines become vertical to the floor.
closeup
Stop valve
mounting bracket
Drainage pipe for floor
Label face up
Stop valve
Rubber packing
Cap
Thermostat
9
Basin in the centre
Hot water supply
Water supply
Drainage pipe for wall
Floor
Cover(small)
Flexible pipe connecting port
Water pipe
Cover(small)
Stop valve

Advertisement