Precautions For Proper Use - Panasonic EQ-500 Series Manual

Adjustable range reflective photoelectric sensor, amplifier built-in multi-voltage
Hide thumbs Also See for EQ-500 Series:
Table of Contents

Advertisement

SENSING CHARACTERISTICS (TYPICAL)
EQ-502 (T) EQ-512 (T)
Sensing fields
• Setting distance: 0.5 m
1.640 ft
0.8
2.625
White non-
Gray non-glossy paper
glossy paper
Lightness: 5
0.6
1.969
200 × 200 mm
0.4
7.874 × 7.874 in
1.312
Non-glossy paper
L
0.2
0.656
Sensor
0
20
10
0
10
20
0.787
0.394
0.394
0.787
Left
Center
Right
Operating point (mm in)
Correlation between color (200 × 200 mm
7.874 × 7.874 in
non-glossy paper) and sensing range
1
3.281
0.5
1.640

PRECAUTIONS FOR PROPER USE

• Never use this product as a sensing device
for personnel protection.
• In case of using sensing devices for
personnel protection, use products which
meet laws and standards, such as OSHA,
ANSI or IEC etc., for personnel protection
applicable in each region or country.
Mounting
• The tightening torque
should be 0.8 N·m or less.
• Care must be taken
regarding the sensor
mounting direction with
respect to the object's
direction of movement.
Correct
Correct
Sensing object
Sensing object
• When detecting a specular object (aluminum or copper foil,
etc.) or an object having a glossy surface or coating, please
note that there are cases when the object may not be detected
due to a change in angle, wrinkles on the object surface, etc.
• If a specular body is present in the background, faulty operation may
be caused due to a small change in the angle of the background
body. In that case, install the sensor at an inclination and confirm the
operation with the actual sensing object.
Adjustable Range Reflective Photoelectric Sensor
• Setting distance: 1 m
3.281 ft
White non-
Gray non-glossy paper
glossy paper
Lightness: 5
1
3.281
200 × 200 mm
7.874 × 7.874 in
0.5
Non-glossy paper
1.640
L
Sensor
0
20
20
10
10
0
0
10
10
0.787
0.394
0.394
Left
Center
Right
Operating point (mm in)
Emitted beam
These bars indicate
the sensing range with
the respective colors
1
when the distance
3.281
adjuster is set to a
sensing range of 1 m
3.281 ft
/ 0.5 m
1.640 ft
long, respectively, with
white non-glossy
0.5
paper.
1.640
The sensing range
also varies depending
on material.
1 m
• • •
3.281 ft
0
0.5 m
• • •
1.640 ft
M5 nut
M5 (length 30 mm
1.181
screw with washers
Sensor
mounting
blacket
MS-EQ5-01
(Optional)
Incorrect
Do not make the sensor
detect an object in this
direction because it may
Sensing object
cause unstable operation.
Correlation between material
(200 × 200 mm
7.874 × 7.874
1
3.281
0.5
1.640
0
20
20
0.787
Correlation between sensing object size and sensing range
ø26 mm
1
ø1.024 in
3.281
ø20 mm
0.5
ø0.787 in
1.640
0
• When a specular body is present below the sensor, use the
sensor by tilting it slightly upwards to avoid faulty operation.
Incorrect
Specular
face
• This product is not easily affected by the reflected light
intensity since this sensor is the adjustable range reflective
in)
type. When the reflected light intensity is remarkably low, the
sensing range may be affected. In that case, mount the
sensor, while checking light-up of the stable indicator (green).
• The mounting screws of the terminal cover and VR cover
should certainly be tightened to maintain water-resistance;
the tightening torque of the screws should be 0.3 to 0.5 N·m.
Automatic interference prevention function
• When the sensors are mounted closely, use them in the
interference prevented area, as shown below.
3
9. 8 43
2
L mm
in
6. 5 62
or more
1
3. 2 81
Interference
prevented area
0
20
40
60
80
0.787
1.575
2.362
3.15
Mounting interval L (mm in)
• Note that the detection may be unstable depending on
the mounting conditions or the sensing object to be used.
In the state that this product is mounted, be sure to check
the operation with the actual sensing object to be used.
EQ-500
SERIES
in) and sensing range
These bars indicate
the sensing range with
the respective objects
1 m
when the distance
• • •
3.281 ft
adjuster is set to a
sensing range of 1 m
0.5 m
• • •
3.281 ft
/ 0.5 m
1.640 ft
1.640 ft
long, respectively, with
white non-glossy
paper.
Setting distance: 1 m
3.281 ft
This curve shows the
characteristics with
the maximum
White non-
sensing range set to
L
glossy paper
1 m
3.281
white non-glossy
paper
(200 × 200 mm
Sensor
7.874 × 7.874
50
100
150
200
1.969
3.937
5.906
7.874
White non-glossy paper
side length a (mm in)
Correct
Specular
face
Tilt
3
9. 8 43
2
6. 5 62
1
3. 2 81
Interference
prevented area
0
50
100
L mm
in
L mm
in
L mm
in
1.969
3.937
or more
or more
or more
Mounting interval L (mm in)
7
ft, with
in).
150
200
250
5.906
7.874
9.843

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents