Stability Indicator - Panasonic EQ-500 Series Manual

Adjustable range reflective photoelectric sensor, amplifier built-in multi-voltage
Hide thumbs Also See for EQ-500 Series:
Table of Contents

Advertisement

PRECAUTIONS FOR PROPER USE
Timer function (EQ-5□T only)
• EQ-5□T incorporates an OFF-delay timer, which is
useful when the response of the connected device is
slow, etc., and an ON-delay timer, which is useful for
detecting objects that move slowly, for example.
• The OFF-delay and ON-delay timers can be used
simultaneously.
• For DC-voltage type, set the DIP switch for the timer
mode to 'Timer ON' side.
Time chart
Sensing
condition
Operation
Detection
normal operation
Detection ON-delay
T
Detection OFF-delay
Detection ON/OFF-delay
T
Non-detection
normal operation
Non-detection ON-delay
Non-detection OFF-delay
T
Non-detection
T
ON/OFF-delay
DIMENSIONS (Unit: mm in)
EQ-501(T) EQ-502(T) EQ-511(T) EQ-512(T)
Stability indicator (Green)
Distance adjuster (2-turn)
Adjuster indicator
Operation indicator (Orange)
2
26
0.079
Beam-
1.024
receiving part
Center of beam-
emitting
(Center of sensing)
68
58
2.677
2.283
22
0.866
5
0.197
5
0.197
Notes: 1) The operation mode switch of the DC-voltage type is the DIP
switch.
2) For EQ-5□T only.
Adjustable Range Reflective Photoelectric Sensor
Detection
Non-
detection
ON
OFF
ON
OFF
ON
T
T
T
OFF
ON
T
OFF
ON
OFF
ON
T
T
T
OFF
ON
OFF
ON
T
OFF
Timer period: T = 0.1 to 5 sec. (variable)
Operation mode switch (Note 1)
OFF-delay timer adjuster (Note 2)
ON-delay timer adjuster (Note 2)
3-M5 nut seats
(on both sides)
3-ø5.1
ø0.201
mounting holes
68
2.677
30
1.181
58
2.283

Stability indicator

• Since the EQ-500 series uses a 2-segment photodiode
as its receiving element, and sensing is done based
on the difference in the incident beam angle of the
reflected beam from the sensing object, the output and
the operation indicator (orange) operate according to
the object distance.
Furthermore, the stability indicator (green) shows the
margin of the setting distance.
Setting distance
Output (Operation indicator)
(In case of Detection-ON)
Stability indicator
Stable operating
condition
Others
• Do not use during the initial transient time (50 ms) after
the power supply is switched on.
• Its distance adjuster is mechanically operated. Do not
drop; avoid other shocks.
The CAD data can be downloaded from our website.
Assembly dimensions with sensor mounting bracket
MS-EQ5-01 (Optional) (Foot angled mounting)
6.5
0.256
29
1.142
2-M5 (length 30 1.181) screws
Center of beam-
emitting
(Center of sensing)
37
1.457
26
29
5
1.142
1.024
0.197
Material: Cold rolled carbon steel (SPCC)
Two M5 (length 30 mm
1.181
in) screws with washers and two nuts are attached.
EQ-500
SERIES
Sensing object
ON (Lights up)
OFF (Lights off)
Lights up
Stable operating
condition
Lights off
Unstable
operating condition
Sensor
(30.5)
(1.201)
4
0.157
ø6.5
6.5
ø0.256
0.256
17.5
0.689
58
(10)
(10)
2.283
(0.394)
(0.394)
58
88
2.283
3.465
18
0.709
58
t 2
2.283
t 0.079
78
3.071
9