Part Description - Panasonic EQ-500 Series Specification Sheet

Eq-500 series adjustable range reflective photoelectric sensor
Hide thumbs Also See for EQ-500 Series:
Table of Contents

Advertisement

PRECAUTIONS FOR PROPER USE
Wiring
Make sure that the power supply is off while wiring.
Check all wiring before applying power since incorrect wiring may
damage the internal circuit. Also, carefully tighten the terminal
screws so that the wires of adjacent terminals do not touch.
The mounting hole for the terminal cover fixing screws inclines
70 degrees to the terminal cover, as shown in the figure below.
To avoid damaging this product or screw, take care when
tightening or loosening a screw.
Screw for terminal cover fixing
Screwdriver
To maintain water-resistance, the cable should have an outer
diameter between "9 to "11 mm
smooth covering material that allows the attached conduit
connector to be securely tightened; the tightening torque of the
screw should be of 1.5 to 2.0 N m.
Verify that the supply voltage variation is within the rating.
If power is supplied from a commercial switching regulator,
ensure that the frame ground (F.G.) terminal of the power supply
is connected to an actual ground.
In case noise generating equipment (switching regulator, inverter
motor, etc.) is used in the vicinity of this sensor, connect the
frame ground (F.G.) terminal of the equipment to an actual ground.
Do not run the wires together with high-voltage lines or power
lines or put them in the same raceway. This can cause
malfunction due to induction.
If an external surge voltage exceeding 4 kV is impressed (DC-
voltage type: 1 kV), the internal circuit will be damaged, and a
surge suppressing element should be used.
Prepare the cable end as shown below.
Conduit connector construction and cabling
Conduit connector
Gland packing (Note)
Note:
When assembling the conduit connector, pay attention to the direction
of the gland packing.
Furthermore, in order to maintain water-resistance, fit the gland
packing such that the seating surface of the gland packing contacts
the packing holder part of the terminal cover evenly.
The size of conduit is M20
If pressure terminals are to be used, affix the connected
pressure terminals to a terminal (M3.5 screw).
Dimensions of the suitable crimp terminals
Round type
"3.6
22
0.866
"0.142
or less
or more
10
0.394
or less
7.5
0.295
7
0.276
or less
or less
17
0.669
or less
(After crimping)
Note:
Use crimp terminals with insulating sleeves.
Recommended crimp terminal: Nominal size 1.25
The tightening torque for the terminal screws should be 0.3 to 0.5 N m.
"0.354 to "0.433 in
with a
37 mm
1.457 in
Power supply
Output
25 mm
Gland
0.984 in
1.5.
(Unit: mm in)
Y-shaped type
22
0.866
3.6
0.142
or less
or more
10
0.394
or less
7.5
0.295
7
0.276
or less
or less
17
0.669
or less
(After crimping)
3.5
0.049
0.138.

Part description

Stability indicator (Green)
Distance adjuster (2-turn)
Adjuster indicator
Operation indicator (Orange)
Notes: 1)
The operation mode switch of the DC-voltage type is the DIP
switch. Refer to 'DC-voltage type' of 'Operation mode switch'
for details.
2)
Incorporated on EQ-5 T only.
Operation mode switch
Multi-voltage type (L-ON / D-ON mode only)
Operation mode switch
Note: Turn the operation mode switch gradually and lightly with the attached
screwdriver. Turning with excessive strength will cause damage to the
adjuster.
DC-voltage type
L-ON / D-ON mode
BGS / FGS mode
Timer mode
Not used
BGS / FGS function (DC-voltage type only)
DC-voltage type sensor incorporates BGS / FGS function. Select
either the BGS or FGS function depending on the positions of the
background and sensing object.
BGS / FGS function is set with the operation mode switch.
Depends on a selection of either BGS or FGS function, the out-
put operation changes as follows.
Non-detectable area
L-ON
BGS
D-ON
L-ON
FGS
D-ON
08/2005
EQ-500
OFF-delay timer adjuster (Note 2)
ON-delay timer adjuster (Note 2)
Operation mode switch (Note 1)
Description
Detection-ON mode is obtained when the switch
is turned fully clockwise (L side).
Detection-OFF mode is obtained when the switch
is turned fully counterclockwise (D side).
L
D
BGS
FGS
OFF
Timer ON
N.C.
N.C.
Detectable range
Setting distance
ON
OFF
ON
OFF
ON
OFF
ON
OFF
201

Advertisement

Table of Contents
loading

Table of Contents