WIRING DIAGRAMS
BK
RD
L1
C
N
4
5
6
PLF
Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
RD
YL
WH
GR
TB1
RCCF
H
1
5
OR
BR
YL
WH
PU
SEE NOTE 2
1 2
3
4
5
EM
G
N
L
C
GR
BK
BL
RD
SUPPLY VOLTAGE
208-240/1/60
T2
C
R
T1
C
COM P
S
C
H
RCCF
F
CM
EM
L
G
208-240V
NOTE 3
2
3
1
TR
24V
SEE NOTE #2
1
2
3
EM
4
5
TB1
LPS
HPS
W2
W2
W1
W1
Y2
Y1
Y1
G
G
C
C
S1
S1
S2
S2
O
O
R
R
THERMOSTAT
TB1
NOTE 3
RD
BK
2
3
1
BL
208
240
C
TR
24V
BL
PK
BR
WH
PU
3
6
9
C
F
2
5
8
BR
1
4
7
PLF 1
PU
BK
BR
CM
COMPONENT LEGEND
L2
C
CONTACTOR
CM
CONDENSER MOTOR
COMP
COMPRESSOR
EM
EVAP ORATOR MOTOR
GND
EQUPIMENT GROUND
LVJB
LOW VOLTAGE JUNCTION BOX
PLF
FEMALE PLUG / CONNECTOR
RCCF
RUN CAPACITOR FOR
COMPRESSOR AND FAN
TB1
TERMINAL BLOCK (24V SIGNAL)
TR
TRANSFORMER
NOTES:
1. REPLACEMENT WIRE MUST BE SAME SIZE AND
TYPE INSULATION AS ORIGINAL (AT LEAST 105°C)
USE COPPER CONDUCTOR ONLY.
2. TO CHANGE EVAPORATOR MOTOR SPEED MOVE
WHITE AND YELLOW LEADS FROM "3" AND "4" TO
"4" AND "5". IF BOTH LEADS ARE ENERGIZED, THE
HIGHER SPEE D SETTING IS USED.
3. FOR 208 VOLT TRANSFORMER OPERATION MOVE
BLACK WIRE FROM TERMINAL 3 TO TERMINAL 2
ON TRANSFORMER.
4. USE COPPER CONDUCTORS ONLY
++
USE N.E.C. CLASS 2 WIRE.
5. ECONOMIZER PLUG LOCATED IN RETURN AIR
COMPARTMENT. REMOVE MALE PLUG AND ATTA CH
FEMALE PLUG TO ECONOMIZER ACCESSORY.
SEE UNIT RATING PLATE FOR TYPE AND SIZE
OF OVER CURREN T PROTECTION
C
JUNCTION
TERMINAL
INTERNAL TO
C
INTEGRATED CONTROL
PLUG CONNECTION
SWITCH (PRESS.)
PLF2
8
7
9
OVERCURRENT
6
5
4
PROT. DEVICE
3
2
1
NOTE 5
41
208-230V/1PH/60HZ DIRECT DRIVE
RD
BL
BL
BK
RD
BK
RD
L2
T2
RD
BK
T1
L1
BK
NOTE 4
C
YL
YL/PK
GND
RD
GR
PLF 2
3 6
PU
2
5
1
4
BL
YL
YL
LVJB
YL
PU
RD
GR
GR
WH
WH
BR
BL
BL
BL
OR
RD
TB1
PK
CONTROL BOX
RD
BK
YL
YL/PK
T2
T1
T3
HPS
COMP
SMOKE/FIRE DETECTOR
LPS
REPLACES JUMPER
FACTORY WIRING
LIN E VOLTAGE
L OW VOLTAGE
OPTIONAL HIGH VOLTAGE
OPTIONAL LOW VOLTAGE
FIELD WIRING
HIGH VOLTAGE
LO W VOLTAGE
WIRE CODE
BK BLACK
BL BLUE
BR BROWN
GR GREEN
OR ORANGE
PK PINK
PU PURPLE
RD RED
WH WHITE
YL YELLOW
BL/PK BLUE WITH PINK STRIP
YL/PK YELLOW WITH PINK STRIP
THERMOSTAT
FIELD WIRING
NO ECONOMIZER
W
G
R
Y1
Y2
Y2
C
O
TB1
WITH ECONOMIZER OPTION
W
G
EQUIPMENT GROUND
R
Y1
FIELD GROUND
Y2
C
FIELD SPLICE
O
SWITCH (TEMP)
TB1
IGNITER
2 STAGE COOLING
W
G
R
Y1
Y2
C
O
TB1
208-240/1/60 0140L05413-A
DSC060* SINGLE PHASE
2
0
8
-
2
L2
4
0
/
L1
1
/
6
0
OR
9
NOTE 5
8
7
T
Y1
H
E
Y2
R
R
M
G
O
W1
S
W2
T
C
A
O
T
S2
S1
BL/PK
WH
W
GR
G
RD
R
YL
Y
BL
C
OR
O
STAT
WH
W
GR
G
RD
R
YL
Y
BL
C
OR
O
STAT
WH
W
GR
G
RD
R
YL
Y1
PK
Y2
BL
C
OR
O
STAT

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dsh seriesDsc036Dsc048Dsc060Dsh036Dsh048 ... Show all

Table of Contents